Automated Needle Trap Heart-Cut GC/MS and Needle Trap Comprehensive Two-Dimensional GC/TOF-MS for Breath Gas Analysis in the Clinical Environment

被引:114
作者
Mieth, Maren [1 ]
Schubert, Jochen K. [1 ]
Groeger, Thomas [2 ]
Sabel, Bastian [1 ]
Kischkel, Sabine [1 ]
Fuchs, Patricia [1 ]
Hein, Dietmar [3 ]
Zimmermann, Ralf [2 ,4 ]
Miekisch, Wolfram [1 ]
机构
[1] Univ Rostock, Dept Anesthesiol & Intens Care Med, D-18057 Rostock, Germany
[2] Helmholtz Zentrum Muenchen, Res Ctr Environm Hlth, Inst Ecol Chem, D-85764 Neuherberg, Germany
[3] PAS Technol Deutschland GmbH, D-99441 Magdala, Germany
[4] Univ Rostock, Inst Chem, D-18051 Rostock, Germany
关键词
FLIGHT MASS-SPECTROMETRY; X GC-TOFMS; VOLATILE ORGANIC-COMPOUNDS; SORPTION TRAP; CHROMATOGRAPHY; BIOMARKERS; FLOW; SEPARATIONS; DISCOVERY; SYSTEM;
D O I
10.1021/ac100061k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study was intended to evaluate low-volume (20 mL) multibed needle trap (NTD) sampling combined with heart-cut gas chromatography/mass spectrometry (GC/MS) and comprehensive two-dimensional gas chromatography/time-of-flight mass spectrometry (GC x GC/TOF-MS) for trace gas analysis under clinical conditions. NTDs, high-throughput automatic desorption and separation systems, were tested in vitro and within a study in 11 patients undergoing cardiac surgery with respect to reproducibility, reliability, and clinical applicability. NTD-heart-cut GC/MS analysis of standard mixtures containing different volatile organic compounds (VOCs) yielded relative standard deviations (RSDs) from 4.0% to 18.5%. Substance adsorption was stable for 1 day if NTDs were closed on both ends and was stable for approximately 7.8 h when NTD tip ends had to be left open during autosampler storage. Even in the presence of high concentrations of contaminants linearity of heart-cut GC/MS was conserved. In patients' breath potential biomarkers could be determined even in the presence of very high concentrations of sevoflurane. Profiles of blood-borne biomarkers, intravenous drugs, and clinical contaminants were characterized. Comprehensive GC x GC/TOF-MS may be used as a screening tool for new biomarkers, if patterns are generated from deconvoluted normalized areas. Needle trap sampling in combination with hyphenated chromatographic techniques can thus be used to provide well-tailored solutions for complex problems occurring in clinical breath analysis.
引用
收藏
页码:2541 / 2551
页数:11
相关论文
共 46 条
[1]   Integrative Normalization and Comparative Analysis for Metabolic Fingerprinting by Comprehensive Two-Dimensional Gas Chromatography-Time-of-Flight Mass Spectrometry [J].
Almstetter, Martin F. ;
Appel, Inka J. ;
Gruber, Michael A. ;
Lottaz, Claudia ;
Timischl, Birgit ;
Spang, Rainer ;
Dettmer, Katja ;
Oefnert, Peter J. .
ANALYTICAL CHEMISTRY, 2009, 81 (14) :5731-5739
[2]   Airway Monitoring by Collection and Mass Spectrometric Analysis of Exhaled Particles [J].
Almstrand, Ann-Charlotte ;
Ljungstrom, Evert ;
Lausmaa, Jukka ;
Bake, Bjorn ;
Sjovall, Peter ;
Olin, Anna-Carin .
ANALYTICAL CHEMISTRY, 2009, 81 (02) :662-668
[3]   Breath Analysis: The Approach Towards Clinical Applications [J].
Amann, Anton ;
Spanel, Patrik ;
Smith, David .
MINI-REVIEWS IN MEDICINAL CHEMISTRY, 2007, 7 (02) :115-129
[4]   Single column trapping/separation and chemiluminescence detection for on-site measurement of methyl mercaptan and dimethyl sulfide [J].
Azad, Md. Abul Kalam ;
Ohira, Shin-Ichi ;
Toda, Kei .
ANALYTICAL CHEMISTRY, 2006, 78 (17) :6252-6259
[5]  
Birken Thomas, 2006, Technol Health Care, V14, P499
[6]   Human exhaled air analytics: Biomarkers of diseases [J].
Buszewski, Boguslaw ;
Kesy, Martyna ;
Ligor, Tomasz ;
Amann, Anton .
BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (06) :553-566
[7]   Simple sample transfer technique by internally expanded desorptive flow for needle trap devices [J].
Eom, In-Yong ;
Pawliszyn, Janusz .
JOURNAL OF SEPARATION SCIENCE, 2008, 31 (12) :2283-2287
[8]   Development and application of needle trap devices [J].
Eom, In-Yong ;
Tugulea, Anca-Maria ;
Pawliszyn, Janusz .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1196 (1-2) :3-9
[9]   Comprehensive two-dimensional gas chromatography with isotope dilution time-of-flight mass spectrometry for the measurement of dioxins and polychlorinated biphenyls in foodstuffs - Comparison with other methods [J].
Focant, JF ;
Eppe, G ;
Scippo, ML ;
Massart, AC ;
Pirard, C ;
Maghuin-Rogister, G ;
De Pauw, E .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1086 (1-2) :45-60
[10]   Development and application of a needle trap device for time-weighted average diffusive sampling [J].
Gong, Ying ;
Eom, In-Yong ;
Lou, Da-Wei ;
Hein, Dietmar ;
Pawliszyn, Janusz .
ANALYTICAL CHEMISTRY, 2008, 80 (19) :7275-7282