Representing the effect of variation in soft tissue constraints in experimental simulation of total knee replacements

被引:9
作者
Johnston, Helena [1 ]
Abdelgaied, Abdellatif [1 ]
Pandit, Hemant [2 ]
Fisher, John [1 ]
Jennings, Louise M. [1 ]
机构
[1] Univ Leeds, Inst Med & Biol Engn, Leeds, W Yorkshire, England
[2] Univ Leeds, Fac Med & Hlth, Leeds Inst Rheumat & Musculoskeletal Med, Leeds, W Yorkshire, England
基金
英国工程与自然科学研究理事会;
关键词
Total knee replacement; Wear; Soft tissues; Kinematics; Simulation; ARTHROPLASTY; WEAR; POLYETHYLENE; REVISION; FAILURE; LAXITY; TORQUE; HIP;
D O I
10.1016/j.jmbbm.2018.07.011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
As life expectancy and activity levels of patients increase so does the demand on total knee replacements (TKRs). Abnormal mechanics and wear of TKRs can lead to implant loosening and early failure. Polyethylene inserts of varying design and conformity have been introduced in the past decade to improve stability and patient's confidence in the replaced knee, particularly in cases where soft tissue support around the knee is sub optimal. This study experimentally investigated the effect of variation in the soft tissues on the kinematics and wear of a TKR on three different tibial insert designs. DePuy Sigma fixed bearing TKRs with moderately cross-linked UHMWPE and the ISO force control inputs were used. Different soft tissue constraints were simulated using virtual springs in an ISO force controlled simulation system. The spring gaps and stiffness' were varied and their effect on the output kinematics and wear rates assessed. The lower conformity inserts resulted in significantly higher displacements and more variation between the stations on the simulator. They were also more sensitive to changes in the soft tissue constraints than the high conformity insert. The wear rate for the high tension springs was significantly lower than for the lower tension springs tested. Tibial insert geometry and soft tissue constraints significantly affected kinematics and wear in these experimental simulations. Soft tissue constraints and the variability in patients are important considerations in the stratified design of TKRs and approach to patient selection.
引用
收藏
页码:87 / 94
页数:8
相关论文
共 27 条
  • [1] Abdelgaied A, 2017, P I MECH ENG H
  • [2] The effect of insert conformity and material on total knee replacement wear
    Abdelgaied, Abdellatif
    Brockett, Claire L.
    Liu, Feng
    Jennings, Louise M.
    Jin, Zhongmin
    Fisher, John
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2014, 228 (01) : 98 - 106
  • [3] [Anonymous], 2014, IMPLANTS SURG WEAR 3
  • [4] [Anonymous], 2009, IMPLANTS SURG WEAR 1
  • [5] Soft-tissue tension total knee arthroplasty
    Asano, H
    Hoshino, A
    Wilton, TJ
    [J]. JOURNAL OF ARTHROPLASTY, 2004, 19 (05) : 558 - 561
  • [6] Babazadeh P, 2009, ORTHOP REV, V1
  • [7] Comparison of wear in a total knee replacement under different kinematic conditions
    Barnett, PI
    Fisher, J
    Auger, DD
    Stone, MH
    Ingham, E
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2001, 12 (10-12) : 1039 - 1042
  • [8] The effect of patient age at intervention on risk of implant revision after total replacement of the hip or knee: a population-based cohort study
    Bayliss, Lee E.
    Culliford, David
    Monk, A. Paul
    Glyn-Jones, Sion
    Prieto-Alhambra, Daniel
    Judge, Andrew
    Cooper, Cyrus
    Carr, Andrew J.
    Arden, Nigel K.
    Beard, David J.
    Price, Andrew J.
    [J]. LANCET, 2017, 389 (10077) : 1424 - 1430
  • [9] Implant migration and failure in total knee arthroplasty is related to body mass index and tibial component size
    Berend, Michael E.
    Ritter, Merrill A.
    Hyldahl, Hans Christian
    Meding, John B.
    Redelman, Ryan
    [J]. JOURNAL OF ARTHROPLASTY, 2008, 23 (06) : 104 - 109
  • [10] The influence of simulator input conditions on the wear of total knee replacements: An experimental and computational study
    Brockett, Claire L.
    Abdelgaied, Abdellatif
    Haythornthwaite, Tony
    Hardaker, Catherine
    Fisher, John
    Jennings, Louise M.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2016, 230 (05) : 429 - 439