Three-dimensional touch interface for medical education

被引:12
作者
Panchaphongsaphak, Bundit
Burgkart, Rainer
Riener, Robert
机构
[1] ETH, Automat Control Lab, CH-8092 Zurich, Switzerland
[2] Tech Univ Munich, Klinikum Rechts Isar, Clin Orthoped & Sport Orthoped, D-81675 Munich, Germany
[3] ETH, Automat Control Lab, CH-8092 Zurich, Switzerland
[4] Univ Hosp Balgrist, Spinal Cord Injury Ctr, CH-8008 Zurich, Switzerland
来源
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE | 2007年 / 11卷 / 03期
关键词
force-torque sensor; man-machine interface; medical education; neuroanatomical training; virtual reality (VR);
D O I
10.1109/TITB.2006.884359
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
We present the technical principle and evaluation of a multimodal virtual reality (VR) system for medical education, called a touch simulator. This touch simulator comes with an innovative three-dimensional (3-D) touch sensitive input device. The device comprises a six-axis force-torque sensor connected to a tangible object representing the shape of an anatomical structure. Information related to the point of contact is recorded by the sensor, processed, and audiovisually displayed. The touch simulator provides a high level of user-friendliness and fidelity compared to other purely graphically oriented simulation environments. In this paper, the touch simulator has been realized as an interactive neuroanatomical training simulator. The user can visualize and manipulate graphical information of the brain surface or different cross-sectional slices by a finger-touch on a brain-like shaped tangible object. We evaluated the system by theoretical derivations, experiments, and subjective questionnaires. In the theoretical analysis, we could show that the contact point estimation error mainly depends on the accuracy and the noise of the sensor, the amount and direction of the applied force, and the geometry of the tangible object. The theoretical results could be validated by experiments: applying a normal force of 10 N on a 120 mm x 120 min x 120 mm cube causes a maximum error o 2.5 +/- 0.7 mm. This error becomes smaller when increasing the contact force. Based on the survey results, the touch simulator may be a useful tool for assisting medical schools in the visualization of brain image data and the study of neuroanatomy.
引用
收藏
页码:251 / 263
页数:13
相关论文
共 21 条
[1]   CONTACT SENSING FROM FORCE MEASUREMENTS [J].
BICCHI, A ;
SALISBURY, JK ;
BROCK, DL .
INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH, 1993, 12 (03) :249-262
[2]  
BOWMAN D, 2004, 3D USER INTERFACES T, P320
[3]  
GORMAN P, 2000, P MED MEETS VIRT REA, P106
[4]  
HINCKLEY K, P 1994 ACM C HUM FAC, P452
[5]  
HOFFMAN H, 1996, 1 VIS HUM PROJ C ON
[6]  
HOFFMAN H, 1998, VIRT WORLD C ON
[7]   Physically touching virtual objects using tactile augmentation enhances the realism of virtual environments [J].
Hoffman, HG .
IEEE 1998 VIRTUAL REALITY ANNUAL INTERNATIONAL SYMPOSIUM, PROCEEDINGS, 1998, :59-63
[8]  
Insko BE, 2001, PASSIVE HAPTICS SIGN, V3007820
[9]  
MAGEE D, 2005, P I EL ENG INT C, P301
[10]   Viewpoint dependence in visual and haptic object recognition [J].
Newell, FN ;
Ernst, MO ;
Tjan, BS ;
Bülthoff, HH .
PSYCHOLOGICAL SCIENCE, 2001, 12 (01) :37-42