Total dose measurement for ion implantation using laser ablation ICP-MS

被引:12
作者
Li, FH
Balazs, MK
Pong, R
机构
[1] Balazs Analyt Lab, Sunnyvale, CA 94089 USA
[2] Implant Ctr, San Jose, CA 95131 USA
关键词
D O I
10.1039/b001796p
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Laser ablation coupled with a quadrupole based ICP-MS (LA-ICP-MS) has been used for quantitative analysis of the total dopant dose implanted in crystalline silicon wafers. Four commonly used dopant ions in the semiconductor industry, namely B-11(+), As-75(+), Sb-121(+) and P-31(+), were studied in this work. The penetration depths and vertical profiles of these implanted ions in silicon were simulated using 'stopping and range of ions in matter' (SRIM) and utilized to help select the laser sampling parameters. The ICP-MS conditions were optimized to obtain the best signal-to-noise (S/N) and signal-to-background (S/B) ratios using the implanted silicon wafers. The linear analytical calibration curves have been constructed from the standardized wafers with both < 100 > and < 111 > crystal orientations. Multiple prime wafers with known dopant ion concentrations implanted at 80 KeV have been used to assess the analytical precision and accuracy of the technique. It is our hope that this method can eventually be utilized to calibrate ion implanters in different fabrications and correlate the total dose levels employed in different fabrication processes for very large scale integration (VLSI) and ultra-large scale integration (ULSI) devices.
引用
收藏
页码:1139 / 1141
页数:3
相关论文
共 50 条
  • [41] Improving alpha spectrometry energy resolution by ion implantation with ICP-MS
    Dion, M. P.
    Liezers, Martin
    Farmer, Orville T., III
    Miller, Brian W.
    Morley, Shannon
    Barinaga, Charles
    Eiden, Greg
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2015, 303 (01) : 877 - 884
  • [42] Investigation of Sr isotope ratios in prehistoric human bones and teeth using laser ablation ICP-MS and ICP-MS after Rb/Sr separation
    Prohaska, T
    Latkoczy, C
    Schultheis, G
    Teschler-Nicola, M
    Stingeder, G
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (08) : 887 - 891
  • [43] Application of laser microdissection ICP-MS for high resolution elemental mapping in mouse brain tissue: A comparative study with laser ablation ICP-MS
    Sussulini, Alessandra
    Becker, J. Sabine
    TALANTA, 2015, 132 : 579 - 582
  • [44] Comparison of 193, 213 and 266 nm laser ablation ICP-MS
    Gonzalez, J
    Mao, XL
    Roy, J
    Mao, SS
    Russo, RE
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (09) : 1108 - 1113
  • [45] Femtosecond laser ablation ICP-MS of fluid inclusions: Validation and prospects
    Courtieu, Clement
    Guillaume, Damien
    Salvi, Stefano
    Freydier, Remi
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2007, 71 (15) : A192 - A192
  • [46] Calibration strategies for laser ablation ICP-MS in biological studies: A review
    Pan, Huijie
    Feng, Liuxing
    Lu, Yanli
    Han, Yachen
    Xiong, Jinping
    Li, Hongmei
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2022, 156
  • [47] Quantification of mixed uranium and zirconium oxides by laser ablation ICP-MS
    Plaue, Jon
    Hartig, Kyle
    Bertoia, Julie
    Czerwinski, Ken
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2011, 241
  • [48] Analysis of trace organo-metallics and metallic components by coupled chromatography ICP-MS and laser ablation ICP-MS techniques
    Lythgoe, PR
    Kilpatrick, G
    Hall, K
    Gize, AP
    Polya, DA
    MINERAL DEPOSITS: RESEARCH AND EXPLORATION, WHERE DO THEY MEET?, 1997, : 75 - 78
  • [49] LASER-ABLATION - ICP-MS OF GEOLOGICAL THIN-SECTIONS
    CHEATHAM, MM
    WHITE, WM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 208 : 137 - ANYL
  • [50] Evaluation of infrared femtosecond laser ablation for the analysis of geomaterials by ICP-MS
    Freydier, R.
    Candaudap, F.
    Poitrasson, F.
    Arbouet, A.
    Chatel, B.
    Dupre, B.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2008, 23 (05) : 702 - 710