Voltammetric Determination of Dopamine at the Surface of TiO2 Nanoparticles Modified Carbon Paste Electrode

被引:0
作者
Mazloum-Ardakani, Mohammad [1 ]
Rajabi, Hossein [1 ]
Beitollahi, Hadi [1 ]
Mirjalili, Bi Bi Fatemah [1 ]
Akbari, Ali
Taghavinia, Nima [2 ]
机构
[1] Yazd Univ, Fac Sci, Dept Chem, Yazd 89195741, Iran
[2] Sharif Univ Technol, Dept Phys, Tehran 14588, Iran
关键词
Dopamine; TiO2; Nanoparticles; Modified carbon paste electrode; Electrocatalysis; PLATINUM NANOPARTICLES; URIC-ACID; CATECHOLAMINES; NANOTUBES;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
In the present paper, the use of a novel carbon paste electrode modified by N,N'(2,3-dihydroxybenzylidene)-1,4-phenylenediamine (DHBPD) and TiO2 nanoparticles prepared by a simple and rapid method for the determination of dopamine (DA) was described. In the first part of the work, cyclic voltammetry was used to investigate the redox properties of this modified electrode at various solution pH values and at various scan rates. A linear segment was found with slope value of about 48 mV/pH in the pH range 2.0 - 12.0. The apparent charge transfer rate constant (k(s)) and transfer coefficient (alpha) for electron transfer between DHBPD and TiO2 nanoparticles-carbon paste electrode were calculated. In the second part of the work, the mediated oxidation of DA at the modified electrode was described. It has been found that under optimum condition in cyclic voltammetry, a high decrease in overpotential occurs for oxidation of DA at the modified electrode. The values of electron transfer coefficients (alpha) and diffusion coefficient (D) were calculated for DA, using electrochemical approaches. Differential pulse voltammetry (DPV) exhibited a linear dynamic range from 0.08 mu M to 20.0 mu M and a detection limit (3 sigma) of 3.14 x 10(-8) M for DA. Finally, this method was used for the determination of DA in DA injection, using standard addition method.
引用
收藏
页码:147 / 157
页数:11
相关论文
共 28 条
[11]   GENERAL EXPRESSION OF THE LINEAR POTENTIAL SWEEP VOLTAMMOGRAM IN THE CASE OF DIFFUSIONLESS ELECTROCHEMICAL SYSTEMS [J].
LAVIRON, E .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1979, 101 (01) :19-28
[12]  
Manjunatha JG, 2009, INT J ELECTROCHEM SC, V4, P187
[13]   Electrocatalytic determination of hydroxylamine with alizarin red S as a homogenous mediator on the glassy carbon electrode [J].
Mazloum-Ardakani, Mohammad ;
Karimi, M. A. ;
Mirdehghan, S. M. ;
Zare, M. M. ;
Mazidi, R. .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 132 (01) :52-59
[14]   Electrocatalytic oxidation and nanomolar determination of guanine at the surface of a molybdenum (VI) complex-TiO2 nanoparticle modified carbon paste electrode [J].
Mazloum-Ardakani, Mohammad ;
Taleat, Z. ;
Beitollahi, H. ;
Salavati-Niasari, M. ;
Mirjalili, B. B. F. ;
Taghavinia, N. .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2008, 624 (1-2) :73-78
[15]  
Mazloum-Ardakani M, 2009, INT J ELECTROCHEM SC, V4, P308
[16]   Electrochemical and catalytic investigations of dopamine and uric acid by modified carbon nanotube paste electrode [J].
Mazloum-Ardakani, Mohammad ;
Beitollahi, Hadi ;
Ganjipour, Bahram ;
Naeimi, Hossein ;
Nejati, Maryam .
BIOELECTROCHEMISTRY, 2009, 75 (01) :1-8
[17]   Electrochemical monitoring of biogenic amine neurotransmission in real time [J].
Michael, DJ ;
Wightman, RM .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 19 (1-2) :33-46
[18]   Electrochemical glucose biosensing by pyranose oxidase immobilized in gold nanoparticle-polyaniline/AgCl/gelatin nanocomposite matrix [J].
Ozdemir, Caglar ;
Yeni, Fatma ;
Odaci, Dilek ;
Timur, Suna .
FOOD CHEMISTRY, 2010, 119 (01) :380-385
[19]   Determination of catecholamines and metanephrines in urine by capillary electrophoresis-electrospray ionization-time-of-fight mass spectrometry [J].
Peterson, ZD ;
Collins, DC ;
Bowerbank, CR ;
Lee, ML ;
Graves, SW .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 776 (02) :221-229
[20]   Simultaneous liquid chromatographic analysis of catecholamines and 4-hydroxy-3-methoxyphenylethylene glycol in human plasma - Comparison of amperometric and coulometric detection [J].
Sabbioni, C ;
Saracino, MA ;
Mandrioli, R ;
Pinzauti, S ;
Furlanetto, S ;
Gerra, G ;
Raggi, MA .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1032 (1-2) :65-71