Dobutamine-atropine stress echocardiography and dipyridamole sestamibi scintigraphy for the detection of coronary artery disease: Limitations and concordance

被引:46
|
作者
Smart, SC
Bhatia, A
Hellman, R
Stoiber, T
Krasnow, A
Collier, BD
Sagar, KB
机构
[1] Univ Wisconsin, Gundersen Lutheran, Div Cardiol, La Crosse, WI 54601 USA
[2] Med Coll Wisconsin, Div Cardiovasc Med, Milwaukee, WI 53226 USA
[3] Med Coll Wisconsin, Div Nucl Med, Milwaukee, WI 53226 USA
关键词
D O I
10.1016/S0735-1097(00)00825-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES We sought to compare dobutamine-atropine stress echocardiography (DASE) and dipyridamole Technetium 99-m (Tc-99m) sestamibi single photon emission computed tomography (SPECT) scintigraphy (DMIBI) for detecting coronary artery disease (CAD). BACKGROUND Both DASE and DMIBI are effective for evaluating patients for CAD, but their concordance and limitations have not been directly compared. METHODS To investigate these aims, patients underwent multistage DASE, DMIBI and coronary angiography within three months. Dobutamine-atropine stress echocardiography and stress-rest DMIBI were performed according to standard techniques and analyzed for their accuracy in predicting the extent of CAD. Segments were assigned to vascular territories according to standard models. Angiography was performed using the Judkin's technique. RESULTS The 183 patients (mean age: 60 +/- 11 years, including 50 women) consisted of 64 patients with no coronary disease and 61 with single-, 40 with two- and 18 with three-vessel coronary disease. Dobutamine-atropine stress echocardiography and DMIBI were similarly sensitive (87%, 104/119 and 80%, 95/119, respectively) for the detection of CAD, but DASE was more specific (91%, 58/64 vs. 73%, 47/64, p < 0.01). Sensitivity was similar for the detection of CAD in patients with single-vessel disease (84%, 51/61 vs. 74%, 45/61, respectively) and multivessel disease (91%, 53/58 vs. 86%, 50/58, respectively). Multiple wall motion ai,normalities and perfusion defects were similarly sensitive for multivessel disease (72%, 42/58 vs. 66%, 38/53, respectively), but, again, DASE was more specific than DMIBI (95%, 119/125 vs. 76%, 95/125, respectively, p < 0.01). Dobutamine-atropine stress echocardiography and DMIBI were moderately concordant for the detection and extent of CAD (Kappa 0.47, p < 0.0001) bur were only fairly (Kappa 0.35, p < 0.001) concordant for the type of abnormalities (normal, fixed, ischemia or mixed). CONCLUSIONS Dobutamine-atropine stress echocardiography and DMIBI were comparable tests for the detection of CAD. Both were very sensitive for the detection of CAD and moderately sensitive for the extent of disease. The only advantage of DASE was greater specificity, especially for multivessel disease. Dobutamine-atropine stress echocardiography may be advantageous in patients with lower probabilities of CAD. CT Am Coil Cardiol 2000;36: 1265-73) (C) 2000 by the American College of Cardiology.
引用
收藏
页码:1265 / 1273
页数:9
相关论文
共 50 条
  • [31] Comparison of dipyridamole thallium scintigraphy and dobutamine stress echocardiography to detect graft coronary artery disease in heart transplant patients
    Redonnet, M
    Derumeaux, G
    MoutonSchleifer, D
    Bouchart, F
    Bessou, JP
    Soyer, R
    LATE GRAFT LOSS, 1997, 28 : 184 - 184
  • [32] High dose dipyridamole stress imaging: Comparison of sestamibi scintigraphy and SD-echocardiography for the detection of coronary artery disease. A multicenter study
    Parodi, G
    Marcassa, C
    Picano, E
    Marzullo, P
    Verna, E
    Bisi, G
    Galli, M
    Pirelli, S
    Sambuceti, G
    Parodi, O
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) : 50157 - 50157
  • [33] Central Anticholinergic Syndrome Following Dobutamine-Atropine Stress Echocardiography
    Wilson, Michael E.
    Lee, Glenn K.
    Chandra, Anupam
    Kane, Garvan C.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2011, 28 (10): : E205 - E206
  • [34] Transient global amnesia after dobutamine-atropine stress echocardiography
    Saura, Daniel
    Penafiel, Pablo
    Morales, Ana
    Albert, Laura
    Martinez, Francisco
    de la Morena, Gonzalo
    Valdes-Chavarri, Mariano
    EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2008, 9 (04): : 567 - 568
  • [35] Dobutamine stress echocardiography for the detection of coronary artery disease in women
    Geleijnse, Marcel L.
    Krenning, Boudewijn J.
    Soliman, Osarna I. I.
    Nemes, Attila
    Galema, Tjebbe W.
    ten Cate, Folkert J.
    AMERICAN JOURNAL OF CARDIOLOGY, 2007, 99 (05): : 714 - 717
  • [36] DOBUTAMINE VERSUS DIPYRIDAMOLE ECHOCARDIOGRAPHY IN CORONARY-ARTERY DISEASE
    PREVITALI, M
    LANZARINI, L
    FERRARIO, M
    TORTORICI, M
    MUSSINI, A
    MONTEMARTINI, C
    CIRCULATION, 1991, 83 (05) : 27 - 31
  • [37] Transient global amnesia complicating dobutamine-atropine stress echocardiography
    Agarwal, Vikram
    Ranjan, Pragya
    Dominguez, Abel Casso
    Thankachen, Jincy
    IJC HEART & VASCULATURE, 2015, 7 : 111 - 112
  • [38] DOBUTAMINE-ATROPINE STRESS ECHOCARDIOGRAPHY AND CLINICAL-DATA FOR PREDICTING LATE CARDIAC EVENTS IN PATIENTS WITH SUSPECTED CORONARY-ARTERY DISEASE
    POLDERMANS, D
    FIORETTI, PM
    BOERSMA, E
    CORNEL, JH
    BORST, F
    VERMEULEN, EGJ
    ARNESE, M
    ELHENDY, A
    ROELANDT, JRTC
    AMERICAN JOURNAL OF MEDICINE, 1994, 97 (02): : 119 - 125
  • [39] Safety of dobutamine-atropine stress echocardiography in patients with ventricular tachycardia
    Smart, S
    Roth, J
    Sagar, K
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) : 91776 - 91776
  • [40] Right ventricular dysfunction during dobutamine-atropine stress echocardiography correlates with global left ventricular dysfunction and multivessel coronary artery disease
    Smart, SC
    Sagar, KB
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 423A - 423A