Determination of cyclosporine in saliva using liquid chromatography-tandem mass spectrometry

被引:25
|
作者
Mendonza, A
Gohh, R
Akhlaghi, F
机构
[1] Univ Rhode Isl, Dept Appl Pharmaceut Sci, Coll Pharm, Kingston, RI 02881 USA
[2] Brown Univ, Rhode Isl Hosp, Div Organ Transplantat, Sch Med, Providence, RI 02903 USA
关键词
cyclosporine; saliva; concentration; liquid chromatography tandem mass spectrometry;
D O I
10.1097/00007691-200410000-00016
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Saliva may offer an alternative specimen for the therapeutic monitoring of cyclosporine (CsA) in children and patients with difficult venous access. For a highly protein-bound drug such as CsA, saliva may also provide a practical approach for measuring the unbound concentration. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is ideally suited for the measurement of drugs in saliva. A solid-phase extraction technique, analytic liquid chromatography over an Aqua Perfect C-18 column, maintained at 65degreesC, and electrospray tandem mass spectrometry were used to quantify CsA in saliva. The method used cyclosporine C (CsC) as the internal standard. Mobile phase comprised of a 97:3 vol/vol mixture of methanol and 30 mmol ammonium acetate at a flow rate of 0.5 mL/min. Chromatograms using mass transitions of m/z 1219.9 --> m/z 1202.9 for CsA and m/z 1235.9 --> m/z 1218.9 for CsC were obtained. The calibration curve was linear from 1 to 300 mug/L with correlation coefficient values ranging from 0.9732 to 0.9968). The lower limit of quantification was 1 mug/L, and limit of detection was 0.6 mug/L with an average extraction recovery of 84.7 +/- 2.6% for CsA and 93.7 +/- 4.4% for CsC from the saliva matrix. The accuracy of the method ranged from 92% to 104.7%, and the intra- and interrun coefficients of variation were 6.9-12.2% and 8.3-12.1%, respectively. The correlation coefficient value between the CsA concentration measurements in 15 paired blood-saliva samples from kidney transplant recipients was 0.695 (P = 0.006). The noninvasive and simple method of saliva collection coupled with the LC-MS/MS quantification technique for CsA analysis would generate novel data that could benefit patients undergoing CsA therapy.
引用
收藏
页码:569 / 575
页数:7
相关论文
共 50 条
  • [41] Determination of Anabolic Steroid and Glucocorticoid Hormones in Chicken and Egg Using Liquid Chromatography-Tandem Mass Spectrometry
    Xu Jin-Zhong
    Zhang Xiao-Yan
    Ding Tao
    Wu Bin
    Shen Chong-Yu
    Jiang Yuan
    Liu Fie
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 37 (03) : 341 - 346
  • [42] Development and validation of a method for determination of corticosteroids in pig fat using liquid chromatography-tandem mass spectrometry
    Toelgyesi, Adam
    Sharma, Virender K.
    Fekete, Jeno
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (5-6): : 403 - 410
  • [43] Simultaneous Determination of 14 Mycotoxins and Analogues in Feeds by Liquid Chromatography-Tandem Mass Spectrometry
    Ying Yong-Fei
    Zhu Cong-Ying
    Wei Min-Jue
    Chen Hui-Hua
    Qu Jian
    Lu Chun-Bo
    Lin Xian-Jun
    Luo Cheng-Jiang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (12) : 1759 - 1764
  • [44] Determination of the coccidiostat diclazuril in poultry feed and meat by liquid chromatography-tandem mass spectrometry
    Mortier, L
    Daeseleire, E
    van Peteghem, C
    ANALYTICA CHIMICA ACTA, 2005, 529 (1-2) : 229 - 234
  • [45] Determination of parabens in serum by liquid chromatography-tandem mass spectrometry: Correlation with lipstick use
    Tahan, Gabriella Padovani
    Souza Santos, Nayara de Kassia
    Albuquerque, Ana Carolina
    Martins, Isarita
    REGULATORY TOXICOLOGY AND PHARMACOLOGY, 2016, 79 : 42 - 48
  • [46] Characterization of Silvestrol Pharmacokinetics in Mice Using Liquid Chromatography-Tandem Mass Spectrometry
    Saradhi, U. V. R. Vijaya
    Gupta, Sneha V.
    Chiu, Ming
    Wang, Jiang
    Ling, Yonghua
    Liu, Zhongfa
    Newman, David J.
    Covey, Joseph M.
    Kinghorn, A. Douglas
    Marcucci, Guido
    Lucas, David M.
    Grever, Michael R.
    Phelps, Mitch A.
    Chan, Kenneth K.
    AAPS JOURNAL, 2011, 13 (03): : 347 - 356
  • [47] Determination of Pentachlorophenol in Milk Powder by Isotope Dilution Liquid Chromatography-Tandem Mass Spectrometry
    Qi Y.
    Li J.
    Li C.
    Xu Q.
    Shipin Kexue/Food Science, 2023, 44 (16): : 324 - 330
  • [48] Liquid chromatography-tandem mass spectrometry for the determination of chrysoidine in yellow-fin tuna
    Gui, Wenjun
    Xu, Yong
    Shou, Linfei
    Zhu, Guonian
    Ren, Yiping
    FOOD CHEMISTRY, 2010, 122 (04) : 1230 - 1234
  • [49] Determination of the active metabolite of prulifloxacin in human plasma by liquid chromatography-tandem mass spectrometry
    Guo, LX
    Qi, ML
    Jin, X
    Wang, P
    Zhao, HQ
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 832 (02): : 280 - 285
  • [50] Simultaneous determination of carbaryl & organophosphorous pesticides in water by liquid chromatography-tandem mass spectrometry
    Park, Keun-Young
    Shin, Jung-Chul
    Pyo, Dongjin
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2018, 31 (01) : 39 - 46