Determination of cyclosporine in saliva using liquid chromatography-tandem mass spectrometry

被引:25
|
作者
Mendonza, A
Gohh, R
Akhlaghi, F
机构
[1] Univ Rhode Isl, Dept Appl Pharmaceut Sci, Coll Pharm, Kingston, RI 02881 USA
[2] Brown Univ, Rhode Isl Hosp, Div Organ Transplantat, Sch Med, Providence, RI 02903 USA
关键词
cyclosporine; saliva; concentration; liquid chromatography tandem mass spectrometry;
D O I
10.1097/00007691-200410000-00016
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Saliva may offer an alternative specimen for the therapeutic monitoring of cyclosporine (CsA) in children and patients with difficult venous access. For a highly protein-bound drug such as CsA, saliva may also provide a practical approach for measuring the unbound concentration. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is ideally suited for the measurement of drugs in saliva. A solid-phase extraction technique, analytic liquid chromatography over an Aqua Perfect C-18 column, maintained at 65degreesC, and electrospray tandem mass spectrometry were used to quantify CsA in saliva. The method used cyclosporine C (CsC) as the internal standard. Mobile phase comprised of a 97:3 vol/vol mixture of methanol and 30 mmol ammonium acetate at a flow rate of 0.5 mL/min. Chromatograms using mass transitions of m/z 1219.9 --> m/z 1202.9 for CsA and m/z 1235.9 --> m/z 1218.9 for CsC were obtained. The calibration curve was linear from 1 to 300 mug/L with correlation coefficient values ranging from 0.9732 to 0.9968). The lower limit of quantification was 1 mug/L, and limit of detection was 0.6 mug/L with an average extraction recovery of 84.7 +/- 2.6% for CsA and 93.7 +/- 4.4% for CsC from the saliva matrix. The accuracy of the method ranged from 92% to 104.7%, and the intra- and interrun coefficients of variation were 6.9-12.2% and 8.3-12.1%, respectively. The correlation coefficient value between the CsA concentration measurements in 15 paired blood-saliva samples from kidney transplant recipients was 0.695 (P = 0.006). The noninvasive and simple method of saliva collection coupled with the LC-MS/MS quantification technique for CsA analysis would generate novel data that could benefit patients undergoing CsA therapy.
引用
收藏
页码:569 / 575
页数:7
相关论文
共 50 条
  • [21] The assay of Melatonin in saliva by high-performance liquid chromatography-tandem mass spectrometry
    Khan, S. A.
    George, R.
    Taylor, P.
    Charles, B. G.
    McGuire, T.
    Heussler, H.
    Cooper, D.
    Norris, R. L. G.
    THERAPEUTIC DRUG MONITORING, 2011, 33 (04) : 490 - 490
  • [22] Quantitative determination of sarsasapogenin in rat plasma using liquid chromatography-tandem mass spectrometry
    Yang, Bo
    Liu, Zhirui
    Hu, Jing
    Lai, Xiaodan
    Xia, Peiyuan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1022 : 213 - 219
  • [23] Accuracy evaluation of Roche and Siemens tacrolimus and cyclosporine assays in comparison with liquid chromatography-tandem mass spectrometry
    Ko, Dae-Hyun
    Cho, Eun-Jung
    Lee, Woochang
    Chun, Sail
    Min, Won-Ki
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2018, 78 (06) : 431 - 438
  • [24] Determination of 17 potential endocrine-disrupting chemicals in human saliva by dispersive liquid-liquid microextraction and liquid chromatography-tandem mass spectrometry
    de Oliveira, Mariana Lepri
    Rocha, Bruno Alves
    de Oliveira Souza, Vanessa Cristina
    Barbosa, Fernando, Jr.
    TALANTA, 2019, 196 : 271 - 276
  • [25] Determination of Seven Urinary Metabolites of Organophosphate Esters using Liquid Chromatography-Tandem Mass Spectrometry
    Li Pei
    Zeng Xiang-Ying
    Cui Jun-Tao
    Zhao Ling-Juan
    Yu Zhi-Qiang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 45 (11) : 1648 - 1654
  • [26] Determination of salivary dehydroepiandrosterone using liquid chromatography-tandem mass spectrometry combined with charged derivatization
    Higashi, Tatsuya
    Shibayama, Yujin
    Shimada, Kazutake
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 846 (1-2): : 195 - 201
  • [27] Liquid chromatography-tandem mass spectrometry method for determination of aliskiren in saliva and its application to a clinical trial with healthy volunteers
    Burckhardt, Bjoern B.
    Tins, Jutta
    Laeer, Stephanie
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 96 : 118 - 126
  • [28] Noninvasive determination of human cortisol and dehydroepiandrosterone sulfate using liquid chromatography-tandem mass spectrometry
    Cao, Zhimin
    Wemm, Stephanie E.
    Han, Liqiao
    Spink, David C.
    Wulfert, Edelgard
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (06) : 1203 - 1210
  • [29] Primary aromatic amines in kitchenware: Determination by liquid chromatography-tandem mass spectrometry
    Favaro Perez, Mary Angela
    Padula, Marisa
    Moitinho, Daisy
    Grespan Bottoli, Carla Beatriz
    JOURNAL OF CHROMATOGRAPHY A, 2019, 1602 : 217 - 227
  • [30] Steroid profiling in nails using liquid chromatography-tandem mass spectrometry
    Voegel, Clarissa Daniela
    La Marca-Ghaemmaghami, Pearl
    Ehlert, Ulrike
    Baumgartner, Markus R.
    Kraemer, Thomas
    Binz, Tina Maria
    STEROIDS, 2018, 140 : 144 - 150