Determination of cyclosporine in saliva using liquid chromatography-tandem mass spectrometry

被引:25
作者
Mendonza, A
Gohh, R
Akhlaghi, F
机构
[1] Univ Rhode Isl, Dept Appl Pharmaceut Sci, Coll Pharm, Kingston, RI 02881 USA
[2] Brown Univ, Rhode Isl Hosp, Div Organ Transplantat, Sch Med, Providence, RI 02903 USA
关键词
cyclosporine; saliva; concentration; liquid chromatography tandem mass spectrometry;
D O I
10.1097/00007691-200410000-00016
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Saliva may offer an alternative specimen for the therapeutic monitoring of cyclosporine (CsA) in children and patients with difficult venous access. For a highly protein-bound drug such as CsA, saliva may also provide a practical approach for measuring the unbound concentration. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is ideally suited for the measurement of drugs in saliva. A solid-phase extraction technique, analytic liquid chromatography over an Aqua Perfect C-18 column, maintained at 65degreesC, and electrospray tandem mass spectrometry were used to quantify CsA in saliva. The method used cyclosporine C (CsC) as the internal standard. Mobile phase comprised of a 97:3 vol/vol mixture of methanol and 30 mmol ammonium acetate at a flow rate of 0.5 mL/min. Chromatograms using mass transitions of m/z 1219.9 --> m/z 1202.9 for CsA and m/z 1235.9 --> m/z 1218.9 for CsC were obtained. The calibration curve was linear from 1 to 300 mug/L with correlation coefficient values ranging from 0.9732 to 0.9968). The lower limit of quantification was 1 mug/L, and limit of detection was 0.6 mug/L with an average extraction recovery of 84.7 +/- 2.6% for CsA and 93.7 +/- 4.4% for CsC from the saliva matrix. The accuracy of the method ranged from 92% to 104.7%, and the intra- and interrun coefficients of variation were 6.9-12.2% and 8.3-12.1%, respectively. The correlation coefficient value between the CsA concentration measurements in 15 paired blood-saliva samples from kidney transplant recipients was 0.695 (P = 0.006). The noninvasive and simple method of saliva collection coupled with the LC-MS/MS quantification technique for CsA analysis would generate novel data that could benefit patients undergoing CsA therapy.
引用
收藏
页码:569 / 575
页数:7
相关论文
共 28 条
[1]   Distribution of cyclosporin in organ transplant recipients [J].
Akhlaghi, F ;
Trull, AK .
CLINICAL PHARMACOKINETICS, 2002, 41 (09) :615-637
[2]   Unbound cyclosporine and allograft rejection after heart transplantation [J].
Akhlaghi, F ;
Keogh, AM ;
Brown, KF .
TRANSPLANTATION, 1999, 67 (01) :54-59
[3]   LESSON OF THE WEEK - CONVULSIONS ASSOCIATED WITH CYCLOSPORIN-A IN RENAL-TRANSPLANT RECIPIENTS [J].
BEAMAN, M ;
PARVIN, S ;
VEITCH, PS ;
WALLS, J .
BRITISH MEDICAL JOURNAL, 1985, 290 (6462) :139-140
[4]  
COATES JE, 1988, CLIN CHEM, V34, P1545
[5]  
*CTR DRUG EV RES F, 2001, GUID IND BIOAN METH
[6]   CLINICAL AND PHARMACOLOGICAL CORRELATIONS IN CYCLOSPORINE-INDUCED GINGIVAL HYPERPLASIA [J].
DALEY, TD ;
WYSOCKI, GP ;
DAY, C .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1986, 62 (04) :417-421
[7]   THERAPEUTIC DRUG-MONITORING IN SALIVA - AN UPDATE [J].
DROBITCH, RK ;
SVENSSON, CK .
CLINICAL PHARMACOKINETICS, 1992, 23 (05) :365-379
[8]   Cyclosporin -: An updated review of the pharmacokinetic properties, clinical efficacy and tolerability of a microemulsion-based formulation (Neoral®)1 in organ transplantation [J].
Dunn, CJ ;
Wagstaff, AJ ;
Perry, CM ;
Plosker, GL ;
Goa, KL .
DRUGS, 2001, 61 (13) :1957-2016
[9]   CYCLOSPORINE - A REVIEW OF ITS PHARMACODYNAMIC AND PHARMACOKINETIC PROPERTIES, AND THERAPEUTIC USE IN IMMUNOREGULATORY DISORDERS [J].
FAULDS, D ;
GOA, KL ;
BENFIELD, P .
DRUGS, 1993, 45 (06) :953-1040
[10]  
GURECKI J, 1985, TRANSPLANT P, V17, P1997