Visual acuity repeatability in keratoconus: Impact on sample size

被引:32
作者
Gordon, MO [1 ]
Schechtman, KB [1 ]
Davis, LJ [1 ]
McMahon, TT [1 ]
Schornack, J [1 ]
Zadnik, K [1 ]
机构
[1] Washington Univ, Sch Med, Dept Ophthalmol & Visual Sci, St Louis, MO 63110 USA
关键词
visual acuity; keratoconus; repeatability; sample size; low contrast visual acuity;
D O I
10.1097/00006324-199804000-00021
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. The purpose of this paper is to determine the repeatability of visual acuity measurement in keratoconus and to describe the impact of measurement repeatability on sample size. Methods, Approximately 10% of a 1209 patient sample in the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study were selected randomly for a Repeat CLEK Study Visit. Patients were tested at the 15 CLEK Participating Clinics. The test-retest sample consisted of 134 keratoconus patients who met the entry criteria of the CLEK Study. High and low contrast Bailey-Lovie visual acuity was measured with the patient's habitual visual correction (entrance visual acuity monocularly and binocularly), and with the best correction monocularly (either the patient's rigid contact lens and over-refraction, or with a CLEK Study trial lens and appropriate over-refraction) at two visits separated by a median of 90 days (range 22 to 268 days). Results, The mean absolute differences between the number of letters correct at the two visits ranged from a low of 3.24 +/- 3.1 for entrance high contrast binocular acuity to a high of 5.48 +/- 5.1 for best corrected low contrast monocular acuity, Intraclass correlation coefficients ranged from 0.757 to 0.853, The visual acuity score was somewhat higher at the Repeat Visit than at the Baseline Visit when the examiners were different between visits. Conclusions. Given the variable vision reported by keratoconus patients, visual acuity in this sample was very repeatable. Repeatability was slightly poorer when different examiners tested visual acuity at the Baseline and Repeat Visits.
引用
收藏
页码:249 / 257
页数:9
相关论文
共 50 条
  • [41] Forward light scatter and visual acuity before and after intrastromal corneal ring segment implantation at different stages of keratoconus
    Cinta Puell, Maria
    Carballo-Alvarez, Jesus
    ACTA OPHTHALMOLOGICA, 2016, 94 (08) : E738 - E743
  • [42] Impact of pterygium size on corneal topography and visual acuity -: a prospective clinical cross-sectional study
    Seitz, B
    Gütay, A
    Küchle, M
    Kus, MM
    Langenbucher, A
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2001, 218 (09) : 609 - 615
  • [43] Are changes in visual acuity and astigmatism after corneal cross-linking (CXL) in keratoconus predictable?
    Fanka Gilevska
    Alma Biscevic
    Smiljka Popovic Suic
    Maja Bohac
    Sudi Patel
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2021, 259 : 2259 - 2268
  • [44] Patient experience and repeatability of measurements made with the Pentacam HR in patients with keratoconus
    Ingemar Gustafsson
    Dimitrios Bizios
    Anders Ivarsen
    Jesper Ø Hjortdal
    BMC Ophthalmology, 23
  • [45] Patient experience and repeatability of measurements made with the Pentacam HR in patients with keratoconus
    Gustafsson, Ingemar
    Bizios, Dimitrios
    Ivarsen, Anders
    Hjortdal, Jesper O.
    BMC OPHTHALMOLOGY, 2023, 23 (01)
  • [46] Corneal Densitometry: Repeatability in Eyes With Keratoconus and Postcollagen Cross-Linking
    Pahuja, Natasha
    Shetty, Rohit
    Subbiah, Priya
    Nagaraja, Harsha
    Nuijts, Rudy M. M. A.
    Jayadev, Chaitra
    CORNEA, 2016, 35 (06) : 833 - 837
  • [47] CWhatUC: A visual acuity simulator
    Garcia, DD
    Barsky, BA
    Klein, SA
    OPHTHALMIC TECHNOLOGIES VIII, PROCEEDINGS OF, 1998, 3246 : 290 - 298
  • [48] Calculating the mean visual acuity and the change in visual acuity with a decimal acuity chart
    Touzeau, O
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2003, 26 (06): : 586 - 590
  • [49] Effects of Corneal Cross-linking on Contrast Sensitivity, Visual Acuity, and Corneal Topography in Patients With Keratoconus
    Lamy, Ricardo
    Netto, Camila F.
    Reis, Ricardo G.
    Procopio, Bruno
    Porco, Travis C.
    Stewart, Jay M.
    Dantas, Adalmir M.
    Moraes, Haroldo V., Jr.
    CORNEA, 2013, 32 (05) : 591 - 596
  • [50] Visual acuity of snapper Pagrus auratus: effect of size and spectral composition
    Robinson, E.
    Jerrett, A. R.
    Black, S. E.
    Davison, W.
    JOURNAL OF FISH BIOLOGY, 2011, 79 (07) : 1883 - 1894