Visual acuity repeatability in keratoconus: Impact on sample size

被引:32
作者
Gordon, MO [1 ]
Schechtman, KB [1 ]
Davis, LJ [1 ]
McMahon, TT [1 ]
Schornack, J [1 ]
Zadnik, K [1 ]
机构
[1] Washington Univ, Sch Med, Dept Ophthalmol & Visual Sci, St Louis, MO 63110 USA
关键词
visual acuity; keratoconus; repeatability; sample size; low contrast visual acuity;
D O I
10.1097/00006324-199804000-00021
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. The purpose of this paper is to determine the repeatability of visual acuity measurement in keratoconus and to describe the impact of measurement repeatability on sample size. Methods, Approximately 10% of a 1209 patient sample in the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study were selected randomly for a Repeat CLEK Study Visit. Patients were tested at the 15 CLEK Participating Clinics. The test-retest sample consisted of 134 keratoconus patients who met the entry criteria of the CLEK Study. High and low contrast Bailey-Lovie visual acuity was measured with the patient's habitual visual correction (entrance visual acuity monocularly and binocularly), and with the best correction monocularly (either the patient's rigid contact lens and over-refraction, or with a CLEK Study trial lens and appropriate over-refraction) at two visits separated by a median of 90 days (range 22 to 268 days). Results, The mean absolute differences between the number of letters correct at the two visits ranged from a low of 3.24 +/- 3.1 for entrance high contrast binocular acuity to a high of 5.48 +/- 5.1 for best corrected low contrast monocular acuity, Intraclass correlation coefficients ranged from 0.757 to 0.853, The visual acuity score was somewhat higher at the Repeat Visit than at the Baseline Visit when the examiners were different between visits. Conclusions. Given the variable vision reported by keratoconus patients, visual acuity in this sample was very repeatable. Repeatability was slightly poorer when different examiners tested visual acuity at the Baseline and Repeat Visits.
引用
收藏
页码:249 / 257
页数:9
相关论文
共 50 条
  • [31] The Impact of Scleral Contact Lens Vault on Visual Acuity and Comfort
    Otchere, Heinz
    Jones, Lyndon
    Sorbara, Luigina
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2018, 44 : S54 - S59
  • [32] Evaluation of the Reliability and Repeatability of Scheimpflug System Measurement in Keratoconus
    de Luis Eguileor, Beatriz
    Escudero Argaluza, Julene
    Pijoan Zubizarreta, Jose Ignacio
    Santamaria Carro, Alaitz
    Etxebarria Ecenarro, Jaime
    CORNEA, 2018, 37 (02) : 177 - 181
  • [33] Repeatability of Placido-Based Corneal Topography in Keratoconus
    Ortiz-Toquero, Sara
    Rodriguez, Guadalupe
    de Juan, Victoria
    Martin, Raul
    OPTOMETRY AND VISION SCIENCE, 2014, 91 (12) : 1467 - 1473
  • [34] Prediction of Best-Corrected Visual Acuity With Swept-Source Optical Coherence Tomography Parameters in Keratoconus
    Esaka, Yuri
    Kojima, Takashi
    Dogru, Murat
    Hasegawa, Asato
    Tamaoki, Akeno
    Uno, Yunako
    Nishida, Tomoya
    Nakamura, Tomoaki
    Hara, Syuya
    Ichikawa, Kazuo
    CORNEA, 2019, 38 (09) : 1154 - 1160
  • [35] Repeatability of mesopic visual acuity measurements using high- and low-contrast ETDRS letter charts
    Ana Barrio
    Beatriz Antona
    María C. Puell
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2015, 253 : 791 - 795
  • [36] Measuring the impact of suppression on visual acuity in children with amblyopia using a dichoptic visual acuity chart
    Zhu, Bixia
    Liao, Meng
    Liu, Longqian
    FRONTIERS IN NEUROSCIENCE, 2022, 16
  • [37] Repeatability of mesopic visual acuity measurements using high- and low-contrast ETDRS letter charts
    Barrio, Ana
    Antona, Beatriz
    Puell, Maria C.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2015, 253 (05) : 791 - 795
  • [38] Impact of Positive and Negative Defocus on Visual Acuity
    Vasudevan, B.
    Bradley, A.
    Thibos, L. N.
    Martin, J.
    Nam, J.
    Himebaugh, N. L.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [39] The impact of irregular corneal shape parameters on visual acuity and contrast sensitivity
    Sanita Liduma
    Artis Luguzis
    Gunta Krumina
    BMC Ophthalmology, 20
  • [40] The impact of irregular corneal shape parameters on visual acuity and contrast sensitivity
    Liduma, Sanita
    Luguzis, Artis
    Krumina, Gunta
    BMC OPHTHALMOLOGY, 2020, 20 (01)