Visual acuity repeatability in keratoconus: Impact on sample size

被引:32
|
作者
Gordon, MO [1 ]
Schechtman, KB [1 ]
Davis, LJ [1 ]
McMahon, TT [1 ]
Schornack, J [1 ]
Zadnik, K [1 ]
机构
[1] Washington Univ, Sch Med, Dept Ophthalmol & Visual Sci, St Louis, MO 63110 USA
关键词
visual acuity; keratoconus; repeatability; sample size; low contrast visual acuity;
D O I
10.1097/00006324-199804000-00021
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. The purpose of this paper is to determine the repeatability of visual acuity measurement in keratoconus and to describe the impact of measurement repeatability on sample size. Methods, Approximately 10% of a 1209 patient sample in the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study were selected randomly for a Repeat CLEK Study Visit. Patients were tested at the 15 CLEK Participating Clinics. The test-retest sample consisted of 134 keratoconus patients who met the entry criteria of the CLEK Study. High and low contrast Bailey-Lovie visual acuity was measured with the patient's habitual visual correction (entrance visual acuity monocularly and binocularly), and with the best correction monocularly (either the patient's rigid contact lens and over-refraction, or with a CLEK Study trial lens and appropriate over-refraction) at two visits separated by a median of 90 days (range 22 to 268 days). Results, The mean absolute differences between the number of letters correct at the two visits ranged from a low of 3.24 +/- 3.1 for entrance high contrast binocular acuity to a high of 5.48 +/- 5.1 for best corrected low contrast monocular acuity, Intraclass correlation coefficients ranged from 0.757 to 0.853, The visual acuity score was somewhat higher at the Repeat Visit than at the Baseline Visit when the examiners were different between visits. Conclusions. Given the variable vision reported by keratoconus patients, visual acuity in this sample was very repeatable. Repeatability was slightly poorer when different examiners tested visual acuity at the Baseline and Repeat Visits.
引用
收藏
页码:249 / 257
页数:9
相关论文
共 50 条
  • [1] Repeatability of refraction and corrected visual acuity in keratoconus
    Davis, LJ
    Schechtman, KB
    Begley, CG
    Shin, JA
    Zadnik, K
    OPTOMETRY AND VISION SCIENCE, 1998, 75 (12) : 887 - 896
  • [2] Keratoconus stage impact on visual acuity and contrast sensitivity
    Lidum, Sanita
    Luguzis, Artis
    Krumina, Gunta
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [3] Keratoconus apex positions impact on visual acuity and contrast sensitivity
    Liduma, Sanita
    Luguzis, Artis
    Krumina, Gunta
    BIOMEDICAL SPECTROSCOPY, MICROSCOPY, AND IMAGING, 2020, 11359
  • [4] Visual Acuity Examination Methodology in Keratoconus
    Nandzik, Magdalena
    Wylegala, Edward
    Wylegala, Adam
    Szkodny, Dominika
    Roszkowska, Anna Maria
    Wroblewska-Czajka, Ewa
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (24)
  • [5] Repeatability of visual acuity measurement
    Raasch, TW
    Bailey, IL
    Bullimore, MA
    OPTOMETRY AND VISION SCIENCE, 1998, 75 (05) : 342 - 348
  • [6] Validity and Repeatability of a Novel Dynamic Visual Acuity System
    Hirano, Mariko
    Hutchings, Natalie
    Simpson, Trefford
    Dalton, Kristine
    OPTOMETRY AND VISION SCIENCE, 2017, 94 (05) : 616 - 625
  • [7] Time Controlled Visual Acuity - Repeatability and Its Relation to Conventional Visual Acuity
    Maissa, C. A.
    Guillon, M.
    Wong, S.
    Lebois, C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [8] Longitudinal Changes in Corneal Irregular Astigmatism and Visual Acuity in Eyes with Keratoconus
    Mariko Suzuki
    Shiro Amano
    Norihiko Honda
    Tomohiko Usui
    Satoru Yamagami
    Tetsuro Oshika
    Japanese Journal of Ophthalmology, 2007, 51 : 265 - 269
  • [9] Longitudinal changes in corneal irregular astigmatism and visual acuity in eyes with keratoconus
    Suzuki, Mariko
    Amano, Shiro
    Honda, Norihiko
    Usui, Tomohiko
    Yamagami, Satoru
    Oshika, Tetsuro
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2007, 51 (04) : 265 - 269
  • [10] Repeatability of ocular aberration measurements in patients with keratoconus
    Jinabhai, Amit
    Radhakrishnan, Hema
    O'Donnell, Clare
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2011, 31 (06) : 588 - 594