Odontoid plate fixation without C1-C2 arthrodesis: Biomechanical testing of a novel surgical technique and comparison to the conventional screw fixation procedure

被引:6
|
作者
Platzer, Patrick [1 ]
Eipeldauer, Stefan [1 ]
Vecsei, Vilmos [1 ]
机构
[1] Med Univ Vienna, Dept Trauma Surg, A-1090 Vienna, Austria
关键词
Odontoid fractures; Plate fixation; Biomechanical testing; FRACTURES; STABILIZATION;
D O I
10.1016/j.clinbiomech.2010.03.012
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Odontoid plate fixation without C1-C2 arthrodesis appears to be a practicable option for the management of odontoid fractures that are not amenable for conventional screw fixation. The purpose of this study was to measure the mechanical stability of odontoid plate fixation using a specially designed plate construct, and to compare the results to those after conventional screw fixation. Methods: The second cervical vertebra was removed from twenty fresh human spinal columns. Stiffness and failure load of the intact odontoid were measured, and type II odontoid fractures were created. Afterward, the specimens were randomly assigned to one of the following four groups: Group I: plate-fixation; Group II: 2-AO-screw-fixation; Group III: 1-AO-screw-fixation; Group IV: Herbert-screw-fixation. In a second series, stiffness and failure load of the stabilized odontoid fractures were assessed for comparison and statistical analysis. Findings: Group I showed a significantly higher mean failure load than the other groups. The mean failure load of Group I after fixation of the odontoid fracture was 86% of the mean failure load of the intact odontoid. Comparing Groups II, III and IV. there was no significant difference regarding the failure load. In these three groups the mean failure load after odontoid fixation was approximately 50% of the mean failure load of the intact odontoid. Interpretation: Odontoid plate fixation as an alternative procedure in certain fracture patterns provided a significantly higher biomechanical stability than the technique of odontoid screw fixation. Using a specially designed plate construct, 86% of the original stability of the intact odontoid was restored. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:623 / 627
页数:5
相关论文
共 25 条
  • [21] Construct stability of an instrumented 2-level cervical corpectomy model following fatigue testing: biomechanical comparison of circumferential antero-posterior instrumentation versus a novel anterior-only transpedicular screw–plate fixation technique
    Heiko Koller
    Werner Schmoelz
    Juliane Zenner
    Alexander Auffarth
    Herbert Resch
    Wolfgang Hitzl
    Davud Malekzadeh
    Lukas Ernstbrunner
    Martina Blocher
    Michael Mayer
    European Spine Journal, 2015, 24 : 2848 - 2856
  • [22] Construct stability of an instrumented 2-level cervical corpectomy model following fatigue testing: biomechanical comparison of circumferential antero-posterior instrumentation versus a novel anterior-only transpedicular screw-plate fixation technique
    Koller, Heiko
    Schmoelz, Werner
    Zenner, Juliane
    Auffarth, Alexander
    Resch, Herbert
    Hitzl, Wolfgang
    Malekzadeh, Davud
    Ernstbrunner, Lukas
    Blocher, Martina
    Mayer, Michael
    EUROPEAN SPINE JOURNAL, 2015, 24 (12) : 2848 - 2856
  • [23] Modified technique for C1-2 screw-rod fixation and fusion using autogenous bicortical iliac crest graft
    Ni, Bin
    Zhou, Fengjin
    Guo, Qunfeng
    Li, Songkai
    Guo, Xiang
    Xie, Ning
    EUROPEAN SPINE JOURNAL, 2012, 21 (01) : 156 - 164
  • [24] Management of fresh odontoid fractures using posterior C1-2 fixation without fusion: a long-term clinical follow-up study
    Ma, Fei
    Fan, Yuanhe
    Liao, Yehui
    Tang, Qiang
    Tang, Chao
    Xu, Shicai
    Wang, Qing
    Lan, Yongshu
    Zhong, Dejun
    JOURNAL OF NEUROSURGERY-SPINE, 2022, 36 (06) : 968 - 978
  • [25] Comparison of palmar fixed-angle plate fixation with K-wire fixation of distal radius fractures (A0 A2, A3, C1) in elderly patients
    Goehre, F.
    Otto, W.
    Schwan, S.
    Mendel, T.
    Vergroesen, P. P.
    Lindemann-Sperfeld, L.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2014, 39 (03) : 249 - 257