Odontoid plate fixation without C1-C2 arthrodesis: Biomechanical testing of a novel surgical technique and comparison to the conventional screw fixation procedure

被引:6
|
作者
Platzer, Patrick [1 ]
Eipeldauer, Stefan [1 ]
Vecsei, Vilmos [1 ]
机构
[1] Med Univ Vienna, Dept Trauma Surg, A-1090 Vienna, Austria
关键词
Odontoid fractures; Plate fixation; Biomechanical testing; FRACTURES; STABILIZATION;
D O I
10.1016/j.clinbiomech.2010.03.012
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Odontoid plate fixation without C1-C2 arthrodesis appears to be a practicable option for the management of odontoid fractures that are not amenable for conventional screw fixation. The purpose of this study was to measure the mechanical stability of odontoid plate fixation using a specially designed plate construct, and to compare the results to those after conventional screw fixation. Methods: The second cervical vertebra was removed from twenty fresh human spinal columns. Stiffness and failure load of the intact odontoid were measured, and type II odontoid fractures were created. Afterward, the specimens were randomly assigned to one of the following four groups: Group I: plate-fixation; Group II: 2-AO-screw-fixation; Group III: 1-AO-screw-fixation; Group IV: Herbert-screw-fixation. In a second series, stiffness and failure load of the stabilized odontoid fractures were assessed for comparison and statistical analysis. Findings: Group I showed a significantly higher mean failure load than the other groups. The mean failure load of Group I after fixation of the odontoid fracture was 86% of the mean failure load of the intact odontoid. Comparing Groups II, III and IV. there was no significant difference regarding the failure load. In these three groups the mean failure load after odontoid fixation was approximately 50% of the mean failure load of the intact odontoid. Interpretation: Odontoid plate fixation as an alternative procedure in certain fracture patterns provided a significantly higher biomechanical stability than the technique of odontoid screw fixation. Using a specially designed plate construct, 86% of the original stability of the intact odontoid was restored. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:623 / 627
页数:5
相关论文
共 25 条
  • [1] PLATE FIXATION OF ODONTOID FRACTURES WITHOUT C1-C2 ARTHRODESIS: PRACTICE OF A NOVEL SURGICAL TECHNIQUE FOR STABILIZATION OF ODONTOID FRACTURES, INCLUDING THE OPPORTUNITY TO EXTEND THE FIXATION TO C3
    Platzer, Patrick
    Thalhammer, Gerhild
    Krumboeck, Anna
    Schuster, Rupert
    Kutscha-Lissberg, Florian
    Zehetgruber, Isabella
    Braunsteiner, Thomas
    Vecsei, Vilmos
    NEUROSURGERY, 2009, 64 (04) : 726 - 733
  • [2] A Novel Anterior Odontoid Screw Plate for C1-C3 Internal Fixation An In Vitro Biomechanical Study
    Hu, Yong
    Dong, Wei-xin
    Kepler, Christopher K.
    Yuan, Zhen-shan
    Sun, Xiao-yang
    Zhang, Jiao
    Xie, Hui
    SPINE, 2016, 41 (02) : E64 - E72
  • [3] Biomechanical Comparison of Conventional Technique Versus Oblique Screw Placement in Plate Fixation
    Karadeniz, Emre
    Balcik, B. Cenk
    Demirors, Huseyin
    Tuncay, I. Cengiz
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2011, 70 (05): : E84 - E87
  • [4] Biomechanical Analysis Comparing Three C1-C2 Transarticular Screw Salvaging Fixation Techniques
    Elgafy, Hossein
    Potluri, Tejaswy
    Goel, Vijay K.
    Foster, Scott
    Faizan, Ahmad
    Kulkarni, Nikhil
    SPINE, 2010, 35 (04) : 378 - 385
  • [5] Combined Anterior Odontoid Screw Fixation and C1-C2 Jefferson Fracture Anterior Fixation: A Step-by-Step Technical Note
    Frati, Alessandro
    Cimatti, Marco
    Ileyassoff, Hernan
    Capobianco, Mattia
    Santoro, Antonio
    Armocida, Daniele
    WORLD NEUROSURGERY, 2024, 184 : 112 - 118
  • [6] Clinical and radiological Comparison of treatment of atlantoaxial instability by posterior C1-C2 transarticular screw fixation or C1 lateral mass-C2 pedicle screw fixation
    Lee, Sun-Ho
    Kim, Eun Sang
    Sung, Joo-Kyung
    Park, Yeun-Mook
    Eoh, Whan
    JOURNAL OF CLINICAL NEUROSCIENCE, 2010, 17 (07) : 886 - 892
  • [7] A meta-analysis of the fusion rate from surgical treatment for odontoid factures: anterior odontoid screw versus posterior C1-C2 arthrodesis
    Shen, Ye
    Miao, Jinhao
    Li, Chao
    Fang, Lei
    Cao, Samantha
    Zhang, Ming
    Yan, Jianhua
    Kuang, Yong
    EUROPEAN SPINE JOURNAL, 2015, 24 (08) : 1649 - 1657
  • [8] Fusion rates for odontoid fractures after treatment by anterior odontoid screw versus posterior C1-C2 arthrodesis: a meta-analysis
    Li Baogui
    Chen Juwen
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2019, 139 (10) : 1329 - 1337
  • [9] Biomechanical comparison of two new atlantoaxial fixation techniques with C1-2 transarticular screw-graft fixation
    Hartl, Roger
    Chamberlain, Robert H.
    Fifield, Mary S.
    Chou, Dean
    Sonntag, Volker K. H.
    Crawford, Neil R.
    JOURNAL OF NEUROSURGERY-SPINE, 2006, 5 (04) : 336 - 342
  • [10] Morphometric Characteristics of C1-C2 Vertebrae to Perform Anterior Transarticular Crossing Screw Fixation
    Tun, Kagan
    Cemil, Berker
    Gokce, Emre Cemal
    TURKISH NEUROSURGERY, 2018, 28 (02) : 270 - 274