Evaluation of the Leap Motion Controller as a New Contact-Free Pointing Device

被引:93
作者
Bachmann, Daniel [1 ]
Weichert, Frank [1 ]
Rinkenauer, Gerhard [2 ]
机构
[1] Univ Dortmund, Dept Comp Sci 7, D-44221 Dortmund, Germany
[2] Leibniz Res Ctr Working Environm & Human Factors, D-44139 Dortmund, Germany
关键词
Leap Motion Controller; Fitts' law; human-computer interaction; PERFORMANCE-MEASURES; INPUT DEVICES; INFORMATION; ACCURACY;
D O I
10.3390/s150100214
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper presents a Fitts' law-based analysis of the user's performance in selection tasks with the Leap Motion Controller compared with a standard mouse device. The Leap Motion Controller (LMC) is a new contact-free input system for gesture-based human-computer interaction with declared sub-millimeter accuracy. Up to this point, there has hardly been any systematic evaluation of this new system available. With an error rate of 7.8 Vo for the LMC and 2.8 Vo for the mouse device, movement times twice as large as for a mouse device and high overall effort ratings, the Leap Motion Controller's performance as an input device for everyday generic computer pointing tasks is rather limited, at least with regard to the selection recognition provided by the LMC.
引用
收藏
页码:214 / 233
页数:20
相关论文
共 55 条
[1]  
[Anonymous], 2000, International Organization for Standardization, Implants for surgery - active implantable medical devices - part 1: General requirements for safety, marking, and for information to be provided by the manufacturer
[2]  
Anusuya MA, 2010, REV INT J COMPUT SCI, V6, P181
[3]  
Apostolellis P, 2014, 2014 IEEE SYMPOSIUM ON 3D USER INTERFACES (3DUI), P153, DOI 10.1109/3DUI.2014.6798866
[4]   Recommended effect size statistics for repeated measures designs [J].
Bakeman, R .
BEHAVIOR RESEARCH METHODS, 2005, 37 (03) :379-384
[5]  
Balakrishnan Ravin., 1997, P ACM SIGCHI C HUMAN, P311, DOI DOI 10.1145/258549.258778
[6]  
Bérard F, 2009, LECT NOTES COMPUT SC, V5727, P400, DOI 10.1007/978-3-642-03658-3_45
[7]  
Bruder G, 2013, 2013 IEEE SYMPOSIUM ON 3D USER INTERFACES (3DUI), P115, DOI 10.1109/3DUI.2013.6550207
[8]   Voluntarily simulated tremor in normal subjects [J].
Burkhard, PR ;
Langston, JW ;
Tetrud, JW .
NEUROPHYSIOLOGIE CLINIQUE-CLINICAL NEUROPHYSIOLOGY, 2002, 32 (02) :119-126
[9]   New Ways of Accessing Information Spaces Using 3D Multitouch Tables [J].
Ch'ng, Eugene .
PROCEEDINGS OF THE 2012 INTERNATIONAL CONFERENCE ON CYBERWORLDS, 2012, :144-150
[10]   User Performance Measures for Evaluating Interactive TV Pointing Devices [J].
Cheong, Kyeong-kyun ;
Kim, Insoo ;
Park, Sung-kwon ;
Park, Yong-jin .
IEEE TRANSACTIONS ON CONSUMER ELECTRONICS, 2011, 57 (03) :1236-1244