Focal liver lesions: interobserver and intraobserver agreement of three-dimensional contrast-enhanced ultrasound-assisted volume measurements

被引:5
作者
Bartolotta, Tommaso Vincenzo [1 ,2 ]
Pinto, Antonio Sidoti [1 ]
Cannella, Roberto [1 ]
Porrello, Giorgia [1 ]
Taravella, Rossana [1 ]
Randazzo, Angelo [1 ]
Taibbi, Adele [1 ]
机构
[1] Univ Hosp Paolo Giaccone, Sect Radiol BiND, Via Vespro 129, I-90127 Palermo, Italy
[2] Fdn Ist Giuseppe Giglio, Dept Radiol, Palermo, Italy
关键词
3D ultrasound; Liver diseases; Contrast-enhanced ultrasonography; Tumor volume; 3D; ULTRASONOGRAPHY; TUMORS; US;
D O I
10.14366/usg.20025
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study was conducted to assess the interobserver and intraobserver agreement of three-dimensional contrast-enhanced ultrasound (3D-CEUS) volume calculations of focal liver lesions (FLLs). Methods: Thirty-nine patients (15 men and 24 women; mean age, 55.4 years) with 39 Flis (mean size, 3.1 +/- 1.8 cm; size range, 1 to 8 cm) prospectively underwent 3D-CEUS. Four readers calculated the volume of each lesion in an independent and blinded fashion in two separate sessions by means of a semi-automatic, commercially available proprietary software. The differences in lesion volumes (cm(3)) among sessions and readers were assessed using the Mann-Whitney U test and the Kruskal-Wallis test. Bland-Altman analysis was also performed. Intraclass correlation coefficients (ICCs) with 95% confidence intervals (95% CIs) were calculated. The statistical significance level was set at P<0.05. Results: Among readers, there were no statistically significant differences in the first (P=0.953) and second (P=0.592) reading sessions for volume calculations of the 39 FLLs, with almost perfect inter-reader agreement (ICC values of the first reading session, 0.996; 95% Cl, 0.992 to 0.998 and ICC value of the second reading session, 0.994; 95% CI, 0.990 to 0.997, respectively). For each of the four readers, there were no significant differences in volume calculations between the two sessions (P=0.503-0.924), and the intrareader agreement was almost perfect for each reader (R1: ICC, 0.995; 95% CI, 0.991 to 0.998; R2: ICC, 0.995; 95% CI, 0.988 to 0.997; R3: ICC, 0.996; 95% CI, 0.992 to 0.998; R4: ICC, 0.985; 95% CI, 0.971 to 0.992). Conclusion: 3D-CEUS volume calculations provided consistent measurements across different readers with almost perfect intrareader agreement.
引用
收藏
页码:333 / 341
页数:9
相关论文
共 18 条
[1]   Hepatocellular cancer response to radiofrequency tumor ablation: contrast-enhanced ultrasound [J].
Bartolotta, Tommaso Vincenzo ;
Taibbi, Adele ;
Midiri, Massimo ;
De Maria, Marcello .
ABDOMINAL IMAGING, 2008, 33 (05) :501-511
[2]   Contrast-enhanced ultrasound of hepatocellular carcinoma: where do we stand? [J].
Bartolotta, Tommaso Vincenzo ;
Taibbi, Adele ;
Midiri, Massimo ;
Lagalla, Roberto .
ULTRASONOGRAPHY, 2019, 38 (03) :200-214
[3]   Detection of liver metastases in cancer patients with geographic fatty infiltration of the liver: the added value of contrast-enhanced sonography [J].
Bartolotta, Tommaso Vincenzo ;
Taibbi, Adele ;
Picone, Dario ;
Anastasi, Andrea ;
Midiri, Massimo ;
Lagalla, Roberto .
ULTRASONOGRAPHY, 2017, 36 (02) :160-169
[4]   Contrast-Enhanced Ultrasound in Focal Liver Lesions: Where Do We Stand? [J].
Bartolotta, Tommaso Vincenzo ;
Vernuccio, Federica ;
Taibbi, Adele ;
Lagalla, Roberto .
SEMINARS IN ULTRASOUND CT AND MRI, 2016, 37 (06) :573-586
[5]   3D versus 2D contrast-enhanced sonography in the evaluation of therapeutic response of hepatocellular carcinoma after locoregional therapies: preliminary findings [J].
Bartolotta, Tommaso Vincenzo ;
Taibbi, Adele ;
Matranga, Domenica ;
Midiri, Massimo ;
Lagalla, Roberto .
RADIOLOGIA MEDICA, 2015, 120 (08) :695-704
[6]   Feasibility of dynamic three-dimensional contrast-enhanced ultrasound in focal liver lesions: Image quality evaluation and correlation of quantification with two-dimensional contrast-enhanced ultrasound [J].
Cao, Jiaying ;
Dong, Yi ;
Fan, Peili ;
Mao, Feng ;
Wang, Wenping .
CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2019, 72 (03) :305-316
[7]   Dynamic Three-Dimensional Contrast-Enhanced Ultrasound to Predict Therapeutic Response of Radiofrequency Ablation in Hepatocellular Carcinoma: Preliminary Findings [J].
Cao, Jiaying ;
Dong, Yi ;
Mao, Feng ;
Wang, Wenping .
BIOMED RESEARCH INTERNATIONAL, 2018, 2018
[8]   Minimally invasive treatment of malignant hepatic tumors: At the threshold of a major breakthrough [J].
Dodd, GD ;
Soulen, MC ;
Kane, RA ;
Livraghi, T ;
Lees, WR ;
Yamashita, Y ;
Gillams, AR ;
Karahan, OI ;
Rhim, H .
RADIOGRAPHICS, 2000, 20 (01) :9-27
[9]   3D analysis is superior to 2D analysis for contrast-enhanced ultrasound in revealing vascularity in focal liver lesions - A retrospective analysis of 83 cases [J].
Dong, Fa-jin ;
Xu, Jin-feng ;
Du, Dong ;
Jiao, Yang ;
Zhang, Lei ;
Li, Min ;
Liu, Hui-yu ;
Xiong, Yi ;
Luo, Hui .
ULTRASONICS, 2016, 70 :221-226
[10]   Clinical utility of three-dimensional US [J].
Downey, DB ;
Fenster, A ;
Williams, JC .
RADIOGRAPHICS, 2000, 20 (02) :559-571