Diffraction enhanced imaging and x-ray fluorescence microtomography for analyzing biological samples

被引:16
作者
Rocha, H. S.
Pereira, G. R.
Anjos, M. J.
Faria, P.
Kellermann, G.
Perez, C. A.
Tirao, G.
Mazzaro, I.
Giles, C.
Lopes, R. T.
机构
[1] Univ Fed Rio de Janeiro, COPPE, Lab Instrumentacao Nucl, BR-68509 Rio de Janeiro, Brazil
[2] Univ Fed Rio de Janeiro, Inst Fis, BR-68509 Rio de Janeiro, Brazil
[3] INCa, Rio De Janeiro, Brazil
[4] Lab Nacl Luz Sincrotron, Campinas, SP, Brazil
[5] UNC, Fac Mat Astron & Fis, Cordoba, Argentina
[6] UFPR, Lab Opt Raios X & Instrumentacao, Curitiba, Parana, Brazil
[7] Univ Estadual Campinas, Lab Cristalog Aplicada & Raios X, Campinas, SP, Brazil
关键词
D O I
10.1002/xrs.973
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
In this work, breast tissue samples were investigated in order to verify the distribution of certain elements by x-ray fluorescence computed tomography (XRFCT) correlated with the characteristics and pathology of each tissue observed by diffraction enhanced imaging (DEI). The DEI system can show details in low attenuation tissues. It is based on the contrast imaging obtained by extinction, diffraction and refraction characteristics and can improve reduction in false positive and false negative diagnoses. XRFCT allows mapping of all elements within the sample, since even a minute fluorescence signal can be detected. DEI imaging techniques revealed the complex structure of the disease, confirmed by the histological section, and showed microstructures in all planes of the sample. The XRFCT showed the distribution of Zn, Cu and Fe at higher concentration. Copyright (C) 2007 John Wiley & Sons, Ltd.
引用
收藏
页码:247 / 253
页数:7
相关论文
共 34 条
[1]  
ALLONZI AM, 2002, ATLAS MORTALIADADE C, P412
[2]   Exploiting the x-ray refraction contrast with an analyser: the state of the art [J].
Bravin, A .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2003, 36 (10A) :A24-A29
[3]   Computed tomography in the fatigue test analysis of an asphaltic mixture [J].
Braz, D ;
da Motta, LMG ;
Lopes, RT .
APPLIED RADIATION AND ISOTOPES, 1999, 50 (04) :661-671
[4]  
Bushuev VA, 1998, CRYSTALLOGR REP+, V43, P538
[5]   A NEW TOMOGRAPHIC DEVICE BASED ON THE DETECTION OF FLUORESCENT X-RAYS [J].
CESAREO, R ;
MASCARENHAS, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 277 (2-3) :669-672
[6]   Diffraction enhanced x-ray imaging [J].
Chapman, D ;
Thomlinson, W ;
Johnston, RE ;
Washburn, D ;
Pisano, E ;
Gmur, N ;
Zhong, Z ;
Menk, R ;
Arfelli, F ;
Sayers, D .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (11) :2015-2025
[7]  
CHAPMAN D, 1995, REV SCI INSTRUM S, V67
[8]   Preparation of tissue samples for X-ray fluorescence microscopy [J].
Chwiej, J ;
Szczerbowska-Boruchowska, M ;
Lankosz, M ;
Wojcik, S ;
Falkenberg, G ;
Stegowski, Z ;
Setkowicz, Z .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2005, 60 (12) :1531-1537
[9]   Identification of fatigue damage in cortical bone by diffraction enhanced imaging [J].
Connor, DM ;
Sayers, D ;
Sumner, DR ;
Zhong, Z .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 548 (1-2) :234-239
[10]   PHASE-CONTRAST IMAGING OF WEAKLY ABSORBING MATERIALS USING HARD X-RAYS [J].
DAVIS, TJ ;
GAO, D ;
GUREYEV, TE ;
STEVENSON, AW ;
WILKINS, SW .
NATURE, 1995, 373 (6515) :595-598