Disposable electrochemical microfluidic device for ultrasensitive detection of egg allergen in wine samples

被引:19
作者
Baldo, Thaisa Aparecida [1 ]
Proenca, Camila dos Anjos [1 ]
Felix, Fabiana da Silva [2 ]
Freitas, Tayane Aguiar [1 ]
Sakata, Solange Kazumi [3 ]
Angnes, Lucio [4 ]
Faria, Ronaldo Censi [1 ]
机构
[1] Univ Fed Sao Carlos, Dept Quim, BR-13565905 Sao Carlos, SP, Brazil
[2] Univ Fed Lavras, Dept Quim, BR-37200900 Lavras, MG, Brazil
[3] Ctr Tecnol Radiacos, Inst Pesquisa Energet & Nucl IPEN CNEN SP, BR-05508000 Sao Paulo, SP, Brazil
[4] Univ Sao Paulo, Inst Quim, BR-05508000 Sao Paulo, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
OVA detection; Immunoassay ultrasensitive detection; Disposable microfluidic platform; FOOD; QUANTIFICATION; ENZYME; IMMUNOSENSOR; RESIDUES;
D O I
10.1016/j.talanta.2021.122447
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Food allergies have been increasing all over the world. Egg is an important component in the food industries and the second most common cause of food allergy, shortly after milk. In the wine industry, egg white is applied as a fining agent for tannin removal. In this study, a sandwich-based immunoassay for ultrasensitive detection of ovalbumin (OVA) in wine samples was developed. The assay involves the use of magnetic beads (MBs) decorated with a polyclonal anti-OVA antibody (Ab(2)) and horseradish peroxidase (HRP), used as label for the quantification in a disposable electrochemical microfluidic device (DE mu D) here developed. The Ab(2)-MB-HRP prepared was applied to capture, separate, and pre-concentrate OVA from wine samples. In the DE mu D, OVA was immunemagnetically captured (OVA-Ab(2)-MB-HRP), producing a sandwich structure (GO-Ab(1)-OVA-Ab(2)-MB-HRP) on the electrode's surface. This arrangement results in an ultrasensitive device, achieving the ultralow limit of detection of 0.2 fg mL(-1) OVA. Five samples of wines were analyzed by using the immuno-magneto-assay which presents excellent accuracy compared with enzyme-linked immunosorbent assay (ELISA).
引用
收藏
页数:9
相关论文
共 28 条
[1]   Targeted proteomics: Current status and future perspectives for quantification of food allergens [J].
Ahsan, Nagib ;
Rao, R. Shyama Prasad ;
Gruppuso, Philip A. ;
Ramratnam, Bharat ;
Salomon, Arthur R. .
JOURNAL OF PROTEOMICS, 2016, 143 :15-23
[2]   Magnetic beads-based electrochemical immunosensor for monitoring allergenic food proteins [J].
Cadkova, Michaela ;
Metelka, Radovan ;
Holubova, Lucie ;
Horak, Daniel ;
Dvorakova, Veronika ;
Bilkova, Zuzana ;
Korecka, Lucie .
ANALYTICAL BIOCHEMISTRY, 2015, 484 :4-8
[3]   Current Technologies of Electrochemical Immunosensors: Perspective on Signal Amplification [J].
Cho, Il-Hoon ;
Lee, Jongsung ;
Kim, Jiyeon ;
Kang, Min-soo ;
Paik, Jean Kyung ;
Ku, Seockmo ;
Cho, Hyun-Mo ;
Irudayaraj, Joseph ;
Kim, Dong-Hyung .
SENSORS, 2018, 18 (01)
[4]   Disposable Microfluidic Immunoarray Device for Sensitive Breast Cancer Biomarker Detection [J].
de Oliveira, Ricardo A. G. ;
Materon, Elsa M. ;
Melendez, Matias E. ;
Carvalho, Andre L. ;
Faria, Ronaldo C. .
ACS APPLIED MATERIALS & INTERFACES, 2017, 9 (33) :27433-27440
[5]   Applications of liquid chromatography-mass spectrometry for food analysis [J].
Di Stefano, Vita ;
Avellone, Giuseppe ;
Bongiorno, David ;
Cunsolo, Vincenzo ;
Muccilli, Vera ;
Sforza, Stefano ;
Dossena, Arnaldo ;
Drahos, Laszlo ;
Vekey, Karoly .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1259 :74-85
[6]   Development of an aptasensor using reduced graphene oxide chitosan complex to detect Salmonella [J].
Dinshaw, Ignatius Julian ;
Muniandy, Shalini ;
Teh, Swe Jyan ;
Ibrahim, Fatimah ;
Leo, Bey Fen ;
Thong, Kwai Lin .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 806 :88-96
[7]   Target Selection Strategies for LC-MS/MS Food Allergen Methods [J].
Downs, Melanie L. ;
Johnson, Philip .
JOURNAL OF AOAC INTERNATIONAL, 2018, 101 (01) :146-151
[8]   A graphene-based label-free voltammetric immunosensor for sensitive detection of the egg allergen ovalbumin [J].
Eissa, Shimaa ;
L'Hocine, Lamia ;
Siaj, Mohamed ;
Zourob, Mohammed .
ANALYST, 2013, 138 (15) :4378-4384
[9]   Amperometric determination of promethazine in tablets using an electrochemically reduced graphene oxide modified electrode [J].
Felix, Fabiana S. ;
Ferreira, Luis M. C. ;
Vieira, Fernanda ;
Trindade, Gerald M. ;
Ferreira, Viviane S. S. A. ;
Angnes, Lucio .
NEW JOURNAL OF CHEMISTRY, 2015, 39 (01) :696-702
[10]   Ultrasensitive immunoassay for detection of Citrus tristeza virus in citrus sample using disposable microfluidic electrochemical device [J].
Freitas, Tayane A. ;
Proenca, Camila A. ;
Baldo, Thaisa A. ;
Materon, Elsa M. ;
Wong, Ademar ;
Magnani, Rodrigo F. ;
Faria, Ronaldo C. .
TALANTA, 2019, 205