DC Breakdown and Space Charge Characteristics of Mineral Oil Impregnated Thermally Upgraded Paper With Different Ageing Conditons

被引:0
作者
Zou, Runhao [1 ]
Hao, Jian [1 ]
Liao, Ruijin [1 ]
机构
[1] Chongqing Univ, State Key Lab Power Transmiss Equipment & Syst Se, Chongqing, Peoples R China
来源
2019 IEEE 20TH INTERNATIONAL CONFERENCE ON DIELECTRIC LIQUIDS (ICDL) | 2019年
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
thermally upgraded paper; space charge; dc breakdown; thermal ageing; INSULATION;
D O I
10.1109/icdl.2019.8796784
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Oil-paper insulation is widely used as the insulating material in transformers. Temperature is one of the major factors causing mineral oil-paper insulation system ageing. In order to relieve mineral oil-paper insulation's thermal ageing problem, the thermally upgraded paper is used as the insulation system. In this paper, a thermal ageing experiment had been conducted on the thermally upgraded paper impregnated in mineral oil. Samples were collected on different days, then the space charge characteristic test was performed using pulsed electro acoustic method (PEA method). DC breakdown tests were conducted with and without pre stressing. A ramp test was conducted to determine the space charge injection threshold voltage. From the experiment result, the space charge injection threshold voltages for mineral oil-thermally upgraded paper at each thermal ageing state are attained. Thermal ageing of the insulation will not influence the space charge injection threshold voltage, but with further deterioration, the higher the corresponding voltage will be. The space charge injection for the samples is homo charge injection. The more the deterioration, the easier it becomes for the injection. Thermal ageing does not influence the DC breakdown voltage significantly. Pre stressing will increase samples' DC breakdown field strength. The more the deterioration of the sample, the more apparent the increase will be.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Space Charge Characteristics of Thermal Aging Oil Paper Insulation under AC/DC Composite Voltage
    Huang X.
    Zhou Y.
    Zhang L.
    Zhang Y.
    Teng C.
    Xue L.
    Gaodianya Jishu/High Voltage Engineering, 2022, 48 (12): : 4800 - 4808
  • [22] Thermal ageing study on palm oil methyl ester-impregnated thermally upgraded kraft paper insulation for reliable application in HVDC converter transformers
    Thavasilingam, Sudhakar
    Venugopal, Nisha Patingareveettil
    Paramasivan, Muthukumar
    Rathinam, Muniraj
    Manikandan, Shanmugam
    Thankaswamy, Jarin
    ELECTRICAL ENGINEERING, 2024, : 4271 - 4288
  • [23] Space Charge Behavior of Oil-Impregnated Paper Insulation Aging at AC-DC Combined Voltages
    Li, Jian
    Wang, Yan
    Bao, Lianwei
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2014, 9 (02) : 635 - 642
  • [24] Effect of Dielectric Barrier Discharge Plasma Treatment on Space Charge Characteristics of Oil-Impregnated Paper
    Gao, Lu
    Neretti, Gabriele
    Fabiani, Davide
    Wu, Kai
    2024 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATIONS, ICHVE 2024, 2024,
  • [25] Comparative Studies on the Aging of Thermally Upgraded Paper Insulation in Palm Fatty Acid Ester, Mineral Oil, and Natural Ester
    Tokunaga, Junko
    Koide, Hidenobu
    Mogami, Kenji
    Hikosaka, Tomoyuki
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2016, 23 (01) : 258 - 265
  • [26] Influence of Oil Paper Composition on the Space Charge Characteristics
    Chen, C. H.
    Wu, Kai
    Su, Rui
    Li, Shengtao
    CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2015, 1 (03): : 10 - 15
  • [27] Temperature Effect on Space Charge Behavior in Oil-impregnated Paper Insulation
    Wang, Da
    Wang, Shi-Qiang
    Lei, Min
    Mu, Hai-Bao
    Zhang, Guan-Jun
    PROCEEDINGS OF 2011 INTERNATIONAL CONFERENCE ON ELECTRICAL INSULATING MATERIALS (ISEIM), 2011, : 378 - 381
  • [28] Quantification of Kraft paper ageing in mineral oil impregnated insulation systems through mechanical characterization
    I. A. Carrascal
    C. Fernández-Diego
    J. A. Casado
    S. Diego
    I. Fernández
    A. Ortiz
    Cellulose, 2018, 25 : 3583 - 3594
  • [29] Quantification of Kraft paper ageing in mineral oil impregnated insulation systems through mechanical characterization
    Carrascal, I. A.
    Fernandez-Diego, C.
    Casado, J. A.
    Diego, S.
    Fernandez, I.
    Ortiz, A.
    CELLULOSE, 2018, 25 (06) : 3583 - 3594
  • [30] Aging Assessment of Synthetic Ester Impregnated Thermally Non-upgraded Kraft Paper through Chemical Markers in Oil
    Matharage, S. Y.
    Liu, Q.
    Wang, Z. D.
    Wilson, G.
    Krause, Ch.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2018, 25 (02) : 507 - 515