Analysis of the performance of antibody capture methods using fluorescent peptides with capillary zone electrophoresis with laser-induced fluorescence

被引:25
作者
Jackman, R
Schmerr, MJ
机构
[1] Iowa State Univ, Ames Lab, Ames, IA 50011 USA
[2] Vet Lab Agcy, Surrey, England
关键词
capillary electrophoresis; fluorescent peptides; immunoaffinity;
D O I
10.1002/elps.200390112
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method to analyze the performance of an antibody capture method using fluorescent peptides by capillary zone electrophoresis using laser-induced fluorescence (CZE-LIF) for detection has been developed. Fluorescent peptides from the prion protein were synthesized and the corresponding antibodies were produced in rabbits against these peptides. The antibodies were used to capture the fluorescent peptides. The antibodies were then bound to protein A Sepharose. After elution, the amount of fluorescent peptide that was captured vs. the total amount placed in the assay was evaluated by CZE-LIF. Of the three peptides used in this evaluation, it was found that the recovery was approximately 25-35%. When the abnormal prion protein was prepared from scrapie-infected brain samples from hamsters and a sheep using the previously described extraction method and this method, the amount of abnormal prion protein that was measured in the fluorescence immunoassay correlated with amounts estimated from Western blot. We conclude that this method can be used to detect abnormal prion protein in a tissue sample.
引用
收藏
页码:892 / 896
页数:5
相关论文
共 21 条
[1]   HYDROPHILIC-INTERACTION CHROMATOGRAPHY FOR THE SEPARATION OF PEPTIDES, NUCLEIC-ACIDS AND OTHER POLAR COMPOUNDS [J].
ALPERT, AJ .
JOURNAL OF CHROMATOGRAPHY, 1990, 499 :177-196
[2]  
Guzman NA, 2001, ELECTROPHORESIS, V22, P3602, DOI 10.1002/1522-2683(200109)22:17<3602::AID-ELPS3602>3.0.CO
[3]  
2-X
[4]   DETERMINATION OF ANTIGEN-ANTIBODY AFFINITY BY IMMUNOCAPILLARY ELECTROPHORESIS [J].
HEEGAARD, NHH .
JOURNAL OF CHROMATOGRAPHY A, 1994, 680 (02) :405-412
[5]  
HJELMELAND LM, 1984, METHOD ENZYMOL, V104, P305
[6]   Transmission of BSE by blood transfusion in sheep [J].
Houston, F ;
Foster, JD ;
Chong, A ;
Hunter, N ;
Bostock, CJ .
LANCET, 2000, 356 (9234) :999-1000
[7]   Automated analytical system for the examination of protein primary structure [J].
Hsieh, YLF ;
Wang, HQ ;
Elicone, C ;
Mark, J ;
Martin, SA ;
Regnier, F .
ANALYTICAL CHEMISTRY, 1996, 68 (03) :455-462
[8]   Transmission of prion diseases by blood transfusion [J].
Hunter, N ;
Foster, J ;
Chong, A ;
McCutcheon, S ;
Parnham, D ;
Eaton, S ;
MacKenzie, C ;
Houston, F .
JOURNAL OF GENERAL VIROLOGY, 2002, 83 :2897-2905
[9]  
HUNTER N, 2002, DEV BIOL, V108, P993
[10]   A europium fluoroimmunoassay for measuring peptide binding to MHC class I molecules [J].
Jensen, PE ;
Moore, JC ;
Lukacher, AE .
JOURNAL OF IMMUNOLOGICAL METHODS, 1998, 215 (1-2) :71-80