Computerized method for nonrigid MR-to-PET breast-image registration

被引:20
作者
Unlu, M. Z. [1 ]
Krol, A. [2 ]
Magri, A. [3 ]
Mandel, J. A. [4 ]
Lee, W. [2 ]
Baum, K. G. [5 ]
Lipson, E. D. [3 ]
Coman, I. L. [6 ]
Feiglin, D. H. [2 ]
机构
[1] Izmir Inst Technol, Dept Elect & Elect Engn, TR-35430 Izmir, Turkey
[2] SUNY Upstate Med Univ, Dept Radiol, Syracuse, NY 13210 USA
[3] Syracuse Univ, Dept Phys, Syracuse, NY 13244 USA
[4] Syracuse Univ, Dept Civil Engn, Syracuse, NY 13244 USA
[5] Rochester Inst Technol, Chester F Carlson Ctr Imaging Sci, Rochester, NY 14623 USA
[6] SUNY Upstate Med Univ, Dept Psychiat & Behav Sci, Syracuse, NY 13210 USA
关键词
MR-to-PET nonrigid breast-image registration; FEM-based soft tissue multimodality nonrigid image registration; PREDICTING MECHANICAL DEFORMATIONS; FREE-FORM DEFORMATION; FDG-PET; CORE-NEEDLE; BIOPSY; CANCER; MODEL; CT; ACQUISITION; MAMMOGRAPHY;
D O I
10.1016/j.compbiomed.2009.10.010
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
We have developed and tested a new simple computerized finite element method (FEM) approach to MR-to-PET nonrigid breast-image registration. The method requires five-nine fiducial skin markers (FSMs) visible in MRI and PET that need to be located in the same spots on the breast and two on the flanks during both scans. Patients need to be similarly positioned prone during MRI and PET scans. This is accomplished by means of a low gamma-ray attenuation breast coil replica used as the breast support during the PET scan. We demonstrate that, under such conditions, the observed FSM displacement vectors between MR and PET images, distributed piecewise linearly over the breast volume, produce a deformed FEM mesh that reasonably approximates nonrigid deformation of the breast tissue between the MRI and PET scans. This method, which does not require a biomechanical breast tissue model, is robust and fast. Contrary to other approaches utilizing voxel intensity-based similarity measures or surface matching, our method works for matching MR with pure molecular images (i.e. PET or SPELT only). Our method does not require a good initialization and would not be trapped by local minima during registration process. All processing including FSMs detection and matching, and mesh generation can be fully automated. We tested our method on MR and PET breast images acquired for 15 subjects. The procedure yielded good quality images with an average target registration error below 4 mm (i.e. well below PET spatial resolution of 6-7 mm). Based on the results obtained for 15 subjects studied to date, we conclude that this is a very fast and a well-performing method for MR-to-PET breast-image nonrigid registration. Therefore, it is a promising approach in clinical practice. This method can be easily applied to nonrigid registration of MRI or CT of any type of soft-tissue images to their molecular counterparts such as obtained using PET and SPELT. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:37 / 53
页数:17
相关论文
共 72 条
  • [1] [Anonymous], 2007, WHAT AR KEY STAT BRE
  • [2] Azar F S, 2001, THESIS U PENNSYLVANI
  • [3] Methods for modeling and predicting mechanical deformations of the breast under external perturbations
    Azar, FS
    Metaxas, DN
    Schnall, MD
    [J]. MEDICAL IMAGE ANALYSIS, 2002, 6 (01) : 1 - 27
  • [4] A deformable finite element model of the breast for predicting mechanical deformations under external perturbations
    Azar, FS
    Metaxas, DN
    Schnall, MD
    [J]. ACADEMIC RADIOLOGY, 2001, 8 (10) : 965 - 975
  • [5] A finite element model of the breast for predicting mechanical deformations during biopsy procedures
    Azar, FS
    Metaxas, DN
    Schnall, MD
    [J]. IEEE WORKSHOP ON MATHEMATICAL METHODS IN BIOMEDICAL IMAGE ANALYSIS, PROCEEDINGS, 2000, : 38 - 45
  • [6] BANKMAN I, 2000, HDB MED IMAGING PROC, pCH29
  • [7] Classification of hypervascularized lesions in CE MR imaging of the breast
    Baum, F
    Fischer, U
    Vosshenrich, R
    Grabbe, E
    [J]. EUROPEAN RADIOLOGY, 2002, 12 (05) : 1087 - 1092
  • [8] Beaulieu S, 2003, J NUCL MED, V44, P1044
  • [9] One hundred consecutive advanced breast biopsy instrumentation procedures: Complications, costs, and outcome
    Bloomston, M
    D'Angelo, P
    Galliano, D
    Butler, J
    Dean, R
    Rosemurgy, AS
    [J]. ANNALS OF SURGICAL ONCOLOGY, 1999, 6 (02) : 195 - 199
  • [10] Bombardieri E, 2001, Q J NUCL MED, V45, P245