Deep learning image reconstruction for pancreatic low-dose computed tomography: comparison with hybrid iterative reconstruction

被引:34
作者
Noda, Yoshifumi [1 ]
Iritani, Yukako [1 ]
Kawai, Nobuyuki [1 ]
Miyoshi, Toshiharu [2 ]
Ishihara, Takuma [3 ]
Hyodo, Fuminori [4 ]
Matsuo, Masayuki [1 ]
机构
[1] Gifu Univ, Dept Radiol, 1-1 Yanagido, Gifu 5011194, Japan
[2] Gifu Univ Hosp, Dept Radiol Serv, 1-1 Yanagido, Gifu 5011194, Japan
[3] Gifu Univ Hosp, Innovat & Clin Res Promot Ctr, 1-1 Yanagido, Gifu 5011194, Japan
[4] Gifu Univ, Frontier Sci Imaging, Dept Radiol, 1-1 Yanagido, Gifu 5011194, Japan
关键词
Multidetector computed tomography; Pancreas; Image processing; Deep learning; ABDOMINAL CT; QUALITY;
D O I
10.1007/s00261-021-03111-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To evaluate image quality, image noise, and conspicuity of pancreatic ductal adenocarcinoma (PDAC) in pancreatic low-dose computed tomography (LDCT) reconstructed using deep learning image reconstruction (DLIR) and compare with those of images reconstructed using hybrid iterative reconstruction (IR). Methods Our institutional review board approved this prospective study. Written informed consent was obtained from all patients. Twenty-eight consecutive patients with PDAC undergoing chemotherapy (14 men and 14 women; mean age, 68.4 years) underwent pancreatic LDCT for therapy evaluation. The LDCT images were reconstructed using 40% adaptive statistical iterative reconstruction-Veo (hybrid-IR) and DLIR at medium and high levels (DLIR-M and DLIR-H). The image noise, diagnostic acceptability, and conspicuity of PDAC were qualitatively assessed using a 5-point scale. CT numbers of the abdominal aorta, portal vein, pancreas, PDAC, background noise, signal-to-noise ratio (SNR) of the anatomical structures, and tumor-to-pancreas contrast-to-noise ratio (CNR) were calculated. Qualitative and quantitative parameters were compared between the hybrid-IR, DLIR-M, and DLIR-H images. Results CT dose-index volumes and dose-length product in pancreatic LDCT were 2.3 +/- 1.0 mGy and 74.9 +/- 37.0 mGy center dot cm, respectively. The image noise, diagnostic acceptability, and conspicuity of PDAC were significantly better in DLIR-H than those in hybrid-IR and DLIR-M (all P < 0.001). The background noise was significantly lower in the DLIR-H images (P < 0.001) and resulted in improved SNRs (P < 0.001) and CNR (P < 0.001) compared with those in the hybrid-IR and DLIR-M images. Conclusion DLIR significantly reduced image noise and improved image quality in pancreatic LDCT images compared with hybrid-IR.
引用
收藏
页码:4238 / 4244
页数:7
相关论文
共 17 条
[1]   Deep learning reconstruction improves image quality of abdominal ultra-high-resolution CT [J].
Akagi, Motonori ;
Nakamura, Yuko ;
Higaki, Toru ;
Narita, Keigo ;
Honda, Yukiko ;
Zhou, Jian ;
Yu, Zhou ;
Akino, Naruomi ;
Awai, Kazuo .
EUROPEAN RADIOLOGY, 2019, 29 (11) :6163-6171
[2]  
[Anonymous], 2019, Clinical Practice Guidelines: Breast Cancer
[3]   Low-dose CT angiography using ASiR-V for potential living renal donors: a prospective analysis of image quality and diagnostic accuracy [J].
Han, Woong Kyu ;
Na, Joon Chae ;
Park, Sung Yoon .
EUROPEAN RADIOLOGY, 2020, 30 (02) :798-805
[4]   Image Quality Assessment of Abdominal CT by Use of New Deep Learning Image Reconstruction: Initial Experience [J].
Jensen, Corey T. ;
Liu, Xinming ;
Tamm, Eric P. ;
Chandler, Adam G. ;
Sun, Jia ;
Morani, Ajaykumar C. ;
Javadi, Sanaz ;
Wagner-Bartak, Nicolaus A. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 215 (01) :50-57
[5]   US Diagnostic Reference Levels and Achievable Doses for 10 Adult CT Examinations [J].
Kanal, Kalpana M. ;
Butler, Priscilla F. ;
Sengupta, Debapriya ;
Bhargavan-Chatfield, Mythreyi ;
Coombs, Laura P. ;
Morin, Richard L. .
RADIOLOGY, 2017, 284 (01) :120-133
[6]   Model-based iterative reconstruction technique for radiation dose reduction in chest CT: comparison with the adaptive statistical iterative reconstruction technique [J].
Katsura, Masaki ;
Matsuda, Izuru ;
Akahane, Masaaki ;
Sato, Jiro ;
Akai, Hiroyuki ;
Yasaka, Koichiro ;
Kunimatsu, Akira ;
Ohtomo, Kuni .
EUROPEAN RADIOLOGY, 2012, 22 (08) :1613-1623
[7]  
Kim JH, 2021, KOREAN J RADIOL, V22, P131
[8]   Value of three-dimensional reconstructions in pancreatic carcinoma using multidetector CT: Initial results [J].
Klauss, Miriam ;
Schoebinger, Max ;
Wolf, Ivo ;
Werner, Jens ;
Meinzer, Hans-Peter ;
Kauczor, Hans-Ulrich ;
Grenacher, Lars .
WORLD JOURNAL OF GASTROENTEROLOGY, 2009, 15 (46) :5827-5832
[9]   Effect of a novel denoising technique on image quality and diagnostic accuracy in low-dose CT in patients with suspected appendicitis [J].
Kolb, Manuel ;
Storz, Corinna ;
Kim, Jong Hyo ;
Weiss, Jakob ;
Afat, Saif ;
Nikolaou, Konstantin ;
Bamberg, Fabian ;
Othman, Ahmed E. .
EUROPEAN JOURNAL OF RADIOLOGY, 2019, 116 :198-204
[10]  
Li Y., 2020, RADIOLOGY, DOI [33937841, DOI 10.1148/RADIOL.2020202317:202317, 10.1148/radiol.2020202317:202317]