Preservation of residual hearing after cochlear implant surgery with slim modiolar electrode

被引:38
|
作者
Iso-Mustajarvi, Matti [1 ,2 ]
Sipari, Sini [1 ,2 ]
Lopponen, Heikki [1 ,2 ]
Dietz, Aarno [1 ]
机构
[1] Univ Eastern Finland, Yliopistonranta 1, Kuopio 70210, Finland
[2] Kuopio Univ Hosp, Ear Nose & Throat Dis, KNK Klin, Puijonlaaksontie 2, Kuopio 70210, Finland
关键词
Cochlear implant; Hearing preservation; Modiolar electrode; Electro-acoustic stimulation; ANGULAR INSERTION DEPTH; MATRIX SENTENCE TEST; SPEECH-PERCEPTION; EARLY OUTCOMES; LOCATION; IMPACT; ARRAY; STIMULATION; MULTICENTER;
D O I
10.1007/s00405-019-05708-x
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Purpose To evaluate the insertion results and hearing preservation of a novel slim modiolar electrode (SME) in patients with residual hearing. Methods We retrospectively collected the data from the medical files of 17 patients (18 ears) implanted with a SME. All patients had functional low frequency hearing (PTA ((0.125-0.5 kHz)) <= 80 dB HL). The insertion results were re-examined from the postoperative cone-beam computed tomography scans. Postoperative thresholds were obtained at the time of switch-on of the sound processors (mean 43 days) and at latest follow-up (mean 582 days). The speech recognition in noise was measured with the Finnish matrix sentence test preoperatively and at follow-up. Results The mean insertion depth angle (IDA) was 395 degrees. Neither scala dislocations nor tip fold over were detected. There were no total hearing losses. Functional low-frequency hearing was preserved in 15/18 (83%) ears at switch-on and in 14/17 (82%) ears at follow-up. According to HEARRING classification, 55% (10/18) had complete HP at switch-on and 41% (7/17) still at follow-up. Thirteen patients (14 ears) were initially fitted with electric-acoustic stimulation and seven patients (8 ears) continued to use it after follow-up. Conclusions The preliminary hearing preservation results with the SME were more favorable than reported for other perimodiolar electrodes. The results show that the array may also be feasible for electro-acoustic stimulation; it is beneficial in that it provides adequate cochlear coverage for pure electrical stimulation in the event of postoperative or progressive hearing loss.
引用
收藏
页码:367 / 375
页数:9
相关论文
共 50 条
  • [21] Cochlear implantation with the nucleus slim modiolar electrode (CI532): a preliminary experience
    Cuda, Domenico
    Murri, Alessandra
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2017, 274 (12) : 4141 - 4148
  • [22] The Relation of Cochlear Implant Electrode Array Type and Position on Continued Hearing Preservation
    Perkins, Elizabeth L.
    Labadie, Robert F.
    O'Malley, Matthew
    Bennett, Marc
    Noble, Jack H.
    Haynes, David S.
    Gifford, Rene
    OTOLOGY & NEUROTOLOGY, 2022, 43 (06) : E634 - E640
  • [23] The association between electrode impedance and short-term outcomes in cochlear implant recipients of slim modiolar and slim straight electrode arrays
    Mussoi, Bruna S.
    Meibos, Alex
    Woodson, Erika
    Sydlowski, Sarah
    COCHLEAR IMPLANTS INTERNATIONAL, 2024, 25 (01) : 59 - 68
  • [24] Residual hearing preservation for cochlear implantation surgery
    Lin, Chung-Ching
    Chiu, Ting
    Chiou, Hong-Ping
    Chang, Chu-Man
    Hsu, Chuan-Jen
    Wu, Hung-Pin
    TZU CHI MEDICAL JOURNAL, 2021, 33 (04): : 359 - 364
  • [25] Hearing Preservation in Cochlear Implant Surgery: A Meta-Analysis
    Snels, Chantal
    IntHout, Joanna
    Mylanus, Emmanuel
    Huinck, Wendy
    Dhooge, Ingeborg
    OTOLOGY & NEUROTOLOGY, 2019, 40 (02) : 145 - 153
  • [26] Correlation of Scalar Cochlear Volume and Hearing Preservation in Cochlear Implant Recipients with Residual Hearing
    Raeth, Mareike
    Schurzig, Daniel
    Timm, Max E.
    Lenarz, Thomas
    Warnecke, Athanasia
    OTOLOGY & NEUROTOLOGY, 2024, 45 (03) : 256 - 265
  • [27] Feasibility of hearing preservation for residual hearing with longer cochlear implant electrodes
    Moteki, Hideaki
    Nishio, Shin-Ya
    Miyagawa, Maiko
    Tsukada, Keita
    Noguchi, Yoshihiro
    Usami, Shin-Ichi
    ACTA OTO-LARYNGOLOGICA, 2018, 138 (12) : 1080 - 1085
  • [28] Hearing preservation in paediatric cochlear implantation with the Nucleus Slim Straight Electrode - our experience
    Schaefer, Simone
    Sladen, Mark
    Nichani, Jaya
    Millward, Kerri
    Lockley, Morag
    O'Driscoll, Martin
    Kluk, Karolina
    Bruce, Iain A.
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2025, 64 (01) : 51 - 58
  • [29] Initial hearing preservation outcomes of cochlear implantation with a slim perimodiolar electrode array
    Woodson, Erika
    Nelson, Rebecca Chota
    Smeal, Molly
    Haberkamp, Thomas
    Sydlowski, Sarah
    COCHLEAR IMPLANTS INTERNATIONAL, 2021, 22 (03) : 148 - 156
  • [30] Hearing Preservation with the Slim MoI di olar Electrode Nucleus CI532® Cochlear Implant: A Preliminary Experience
    Ramos-Macias, Angel
    Borkoski-Barreiro, S. A.
    Falcon-Gonzalez, J. C.
    Ramos-de Miguel, A.
    AUDIOLOGY AND NEURO-OTOLOGY, 2017, 22 (06) : 317 - 325