Preservation of residual hearing after cochlear implant surgery with slim modiolar electrode

被引:39
作者
Iso-Mustajarvi, Matti [1 ,2 ]
Sipari, Sini [1 ,2 ]
Lopponen, Heikki [1 ,2 ]
Dietz, Aarno [1 ]
机构
[1] Univ Eastern Finland, Yliopistonranta 1, Kuopio 70210, Finland
[2] Kuopio Univ Hosp, Ear Nose & Throat Dis, KNK Klin, Puijonlaaksontie 2, Kuopio 70210, Finland
关键词
Cochlear implant; Hearing preservation; Modiolar electrode; Electro-acoustic stimulation; ANGULAR INSERTION DEPTH; MATRIX SENTENCE TEST; SPEECH-PERCEPTION; EARLY OUTCOMES; LOCATION; IMPACT; ARRAY; STIMULATION; MULTICENTER;
D O I
10.1007/s00405-019-05708-x
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Purpose To evaluate the insertion results and hearing preservation of a novel slim modiolar electrode (SME) in patients with residual hearing. Methods We retrospectively collected the data from the medical files of 17 patients (18 ears) implanted with a SME. All patients had functional low frequency hearing (PTA ((0.125-0.5 kHz)) <= 80 dB HL). The insertion results were re-examined from the postoperative cone-beam computed tomography scans. Postoperative thresholds were obtained at the time of switch-on of the sound processors (mean 43 days) and at latest follow-up (mean 582 days). The speech recognition in noise was measured with the Finnish matrix sentence test preoperatively and at follow-up. Results The mean insertion depth angle (IDA) was 395 degrees. Neither scala dislocations nor tip fold over were detected. There were no total hearing losses. Functional low-frequency hearing was preserved in 15/18 (83%) ears at switch-on and in 14/17 (82%) ears at follow-up. According to HEARRING classification, 55% (10/18) had complete HP at switch-on and 41% (7/17) still at follow-up. Thirteen patients (14 ears) were initially fitted with electric-acoustic stimulation and seven patients (8 ears) continued to use it after follow-up. Conclusions The preliminary hearing preservation results with the SME were more favorable than reported for other perimodiolar electrodes. The results show that the array may also be feasible for electro-acoustic stimulation; it is beneficial in that it provides adequate cochlear coverage for pure electrical stimulation in the event of postoperative or progressive hearing loss.
引用
收藏
页码:367 / 375
页数:9
相关论文
共 47 条
[41]   The Impact of Electrode Array Length on Hearing Preservation in Cochlear Implantation [J].
Suhling, Marie-Charlot ;
Majdani, Omid ;
Salcher, Rolf ;
Leifholz, Melanie ;
Buechner, Andreas ;
Lesinski-Schiedat, Anke ;
Lenarz, Thomas .
OTOLOGY & NEUROTOLOGY, 2016, 37 (08) :1006-1015
[42]   Electric-acoustic stimulation of the auditory system -: New technology for severe hearing loss [J].
von Ilberg, C ;
Kiefer, J ;
Tillein, J ;
Pfenningdorff, T ;
Hartmann, R ;
Stürzebecher, E ;
Klinke, R .
ORL-JOURNAL FOR OTO-RHINO-LARYNGOLOGY AND ITS RELATED SPECIALTIES, 1999, 61 (06) :334-340
[43]   Impact of Intrascalar Electrode Location, Electrode Type, and Angular Insertion Depth on Residual Hearing in Cochlear Implant Patients: Preliminary Results [J].
Wanna, George B. ;
Noble, Jack H. ;
Gifford, Rene H. ;
Dietrich, Mary S. ;
Sweeney, Alex D. ;
Zhang, Dongqing ;
Dawant, Benoit M. ;
Rivas, Alejandro ;
Labadie, Robert F. .
OTOLOGY & NEUROTOLOGY, 2015, 36 (08) :1343-1348
[44]   Impact of Electrode Design and Surgical Approach on Scalar Location and Cochlear Implant Outcomes [J].
Wanna, George B. ;
Noble, Jack H. ;
Carlson, Matthew L. ;
Gifford, Rene H. ;
Dietrich, Mary S. ;
Haynes, David S. ;
Dawant, Benoit M. ;
Labadie, Robert F. .
LARYNGOSCOPE, 2014, 124 :S1-S7
[45]   Evolution of electrode array diameter for hearing preservation in cochlear implantation [J].
Yann Nguyen ;
Mosnier, Isabelle ;
Borel, Stephanie ;
Ambert-Dahan, Emmanuelle ;
Bouccara, Didier ;
Bozorg-Grayeli, Alexis ;
Ferrary, Evelyne ;
Sterkers, Olivier .
ACTA OTO-LARYNGOLOGICA, 2013, 133 (02) :116-122
[46]  
Zanetti D, 2015, ACTA OTORHINOLARYNGO, V35, P433, DOI 10.14639/0392-100X-619
[47]   Tip Fold-over in Cochlear Implantation: Case Series [J].
Zuniga, M. Geraldine ;
Rivas, Alejandro ;
Hedley-Williams, Andrea ;
Gifford, Rene H. ;
Dwyer, Robert ;
Dawant, Benoit M. ;
Sunderhaus, Linsey W. ;
Hovis, Kristen L. ;
Wanna, George B. ;
Noble, Jack H. ;
Labadie, Robert F. .
OTOLOGY & NEUROTOLOGY, 2017, 38 (02) :199-206