Impact of metal and plastic stents on endoscopic ultrasound-guided aspiration cytology and core histology of head of pancreas masses

被引:13
作者
Bekkali, Noor L. H. [1 ]
Nayar, Manu K. [1 ]
Leeds, John S. [1 ]
Thornton, Lucy [1 ]
Johnson, Sarah J. [2 ]
Haugk, Beate [2 ]
Darne, Antony [2 ]
Howard-Tripp, Nadia [1 ]
Charnley, Richard M. [3 ]
Bassett, Paul [4 ]
Oppong, Kofi W. [1 ]
机构
[1] Freeman Rd Hosp, HPB Med, Newcastle Upon Tyne, Tyne & Wear, England
[2] Royal Victoria Infirm, Dept Cellular Pathol, Newcastle Upon Tyne, Tyne & Wear, England
[3] Freeman Rd Hosp, HPB Surg, Newcastle Upon Tyne, Tyne & Wear, England
[4] Statsconsultancy Ltd, Amersham, England
关键词
FINE-NEEDLE-ASPIRATION; CLINICAL IMPACT; ACCURACY; ADENOCARCINOMA; SOCIETY; FNA;
D O I
10.1055/a-0824-6982
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background Stents are frequently placed in patients with biliary obstruction due to a mass in the head of the pancreas. The impact of plastic or self-expandable metal stents (SEMSs) on endoscopic ultrasound (EUS)-guided tissue sampling is unclear. This study aimed to assess, using strict pathological criteria, whether stents impair fine-needle aspiration (FNA) or fine-needle biopsy (FNB). Methods All patients with a solid mass in the head of the pancreas who underwent EUS-guided tissue sampling between 2010 and 2016 at our unit were included. Factors with possible impact on diagnostic performance were analyzed using logistic regression. Analysis was performed using both strict (malignant only) and less strict (suspicious for malignancy) cutoffs. Results Of 631 individuals undergoing 698 procedures, 535 (84.8 %) had a final diagnosis of malignancy, 141 had SEMS, 149 had plastic stents, and 341 had no stent. Using strict criteria, SEMS were associated with an increased occurrence of incorrect diagnosis of EUS tissue sampling, with an odds ratio (OR) of 1.96 (95 % confidence interval [CI] 1.24 - 3.10). Increasing tumor size (OR 0.72, 95 %CI 0.59 - 0.87), increasing number of passes (OR 0.84, 95 %CI 0.72 - 0.99), and fork-tip biopsy needle (OR 0.52, 95 %CI 0.31 - 0.86) were independently associated with a decrease in incorrect diagnosis. Repeat tissue sampling was more common with SEMSs (10.2 %) than with plastic stents (2.9 %) or no stents (4.5 %) ( P < 0.02). Conclusion SEMS use had a negative impact on tissue diagnosis in pancreatic head masses, whereas use of a fork-tip biopsy needle and increasing number of passes were independently associated with improved accuracy.
引用
收藏
页码:1044 / 1050
页数:7
相关论文
共 22 条
[1]   Plastic vs. Self-Expandable Metal Stents for Palliation in Malignant Biliary Obstruction: A Series of Meta-Analyses [J].
Almadi, Majid A. ;
Barkun, Alan ;
Martel, Myriam .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2017, 112 (02) :260-273
[2]   Biliary plastic stent does not influence the accuracy of endoscopic ultrasound-guided sampling of pancreatic head masses performed with core biopsy needles [J].
Antonini, Filippo ;
Fuccio, Lorenzo ;
Giorgini, Sara ;
Fabbri, Carlo ;
Frazzoni, Leonardo ;
Scarpelli, Marina ;
Macarri, Giampiero .
DIGESTIVE AND LIVER DISEASE, 2017, 49 (08) :898-902
[3]  
Cancer Research UK, PANCR CANC DIAGN TRE
[4]   Indications, results, and clinical impact of endoscopic ultrasound (EUS)-guided sampling in gastroenterology: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline - Updated January 2017 [J].
Dumonceau, Jean-Marc ;
Deprez, Pierre H. ;
Jenssen, Christian ;
Iglesias-Garcia, Julio ;
Larghi, Alberto ;
Vanbiervliet, Geoffroy ;
Aithal, Guruprasad P. ;
Arcidiacono, Paolo G. ;
Bastos, Pedro ;
Carrara, Silvia ;
Czako, Laszlo ;
Fernandez-Esparrach, Gloria ;
Fockens, Paul ;
Gines, Angels ;
Havre, Roald F. ;
Hassan, Cesare ;
Vilmann, Peter ;
van Hooft, Jeanin E. ;
Polkowski, Marcin .
ENDOSCOPY, 2017, 49 (07) :695-714
[5]   The Impact of Prior Biliary Stenting on the Accuracy and Complication Rate of Endoscopic Ultrasound Fine-Needle Aspiration for Diagnosing Pancreatic Adenocarcinoma [J].
Fisher, Jessica M. ;
Gordon, Stuart R. ;
Gardner, Timothy B. .
PANCREAS, 2011, 40 (01) :21-24
[6]   The presence of a cytopathologist increases the diagnostic accuracy of endoscopic ultrasound-guided fine needle aspiration cytology for pancreatic adenocarcinoma: a meta-analysis [J].
Hebert-Magee, S. ;
Bae, S. ;
Varadarajulu, S. ;
Ramesh, J. ;
Frost, A. R. ;
Eloubeidi, M. A. ;
Eltoum, I. A. .
CYTOPATHOLOGY, 2013, 24 (03) :159-171
[7]   Rapid on-site evaluation of endoscopic-ultrasound-guided fine-needle aspiration diagnosis of pancreatic masses [J].
Iglesias-Garcia, Julio ;
Larino-Noia, Jose ;
Abdulkader, Ihab ;
Enrique Dominguez-Munoz, J. .
WORLD JOURNAL OF GASTROENTEROLOGY, 2014, 20 (28) :9451-9457
[8]   EUS-guided fine needle biopsy sampling using a novel fork-tip needle: a case-control study [J].
Kandel, Pujan ;
Tranesh, Ghassan ;
Nassar, Aziza ;
Bingham, Russell ;
Raimondo, Massimo ;
Woodward, Timothy A. ;
Gomez, Victoria ;
Wallace, Michael B. .
GASTROINTESTINAL ENDOSCOPY, 2016, 84 (06) :1034-1039
[9]   Lower Yield of Endoscopic Ultrasound-Guided Fine-Needle Aspiration in Patients with Pancreatic Head Mass with a Biliary Stent [J].
Kim, John J. ;
Walia, Sukhpreet ;
Lee, Scott H. ;
Patel, Bhavesh ;
Vetsa, Madhavi ;
Zhao, Yan ;
Srikureja, Wichit ;
Laine, Loren .
DIGESTIVE DISEASES AND SCIENCES, 2015, 60 (02) :543-549
[10]   Rapid On-Site Evaluation Does Not Improve Endoscopic Ultrasound-Guided Fine Needle Aspiration Adequacy in Pancreatic Masses: A Meta-Analysis and Systematic Review [J].
Kong, Fanyang ;
Zhu, Jianwei ;
Kong, Xiangyu ;
Sun, Tao ;
Deng, Xuan ;
Du, Yiqi ;
Li, Zhaoshen .
PLOS ONE, 2016, 11 (09)