Chest Compression With Personal Protective Equipment During Cardiopulmonary Resuscitation A Randomized Crossover Simulation Study

被引:46
作者
Chen, Jie [1 ]
Lu, Kai-Zhi [1 ]
Yi, Bin [1 ]
Chen, Yan [1 ]
机构
[1] Third Mil Med Univ, Southwest Hosp, Dept Anaesthesiol, Gaotanyan 19 St, Chongqing 400038, Peoples R China
关键词
HOSPITAL CARDIAC-ARREST; EMERGENCY CARDIOVASCULAR CARE; HEART-ASSOCIATION GUIDELINES; RESCUER FATIGUE; TOKYO SUBWAY; PERFORMANCE; MANAGEMENT; QUALITY; ATTACK;
D O I
10.1097/MD.0000000000003262
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Following a chemical, biological, radiation, and nuclear incident, prompt cardiopulmonary resuscitation (CPR) procedure is essential for patients who suffer cardiac arrest. But CPR when wearing personal protection equipment (PPE) before decontamination becomes a challenge for healthcare workers (HCW). Although previous studies have assessed the impact of PPE on airway management, there is little research available regarding the quality of chest compression (CC) when wearing PPE. A present randomized cross-over simulation study was designed to evaluate the effect of PPE on CC performance using mannequins. The study was set in one university medical center in the China.Forty anesthesia residents participated in this randomized cross-over study. Each participant performed 2 min of CC on a manikin with and without PPE, respectively. Participants were randomized into 2 groups that either performed CC with PPE first, followed by a trial without PPE after a 180-min rest, or vice versa.CPR recording technology was used to objectively quantify the quality of CC. Additionally, participants' physiological parameters and subjective fatigue score values were recorded. With the use of PPE, a significant decrease of the percentage of effective compressions (41.317.1% with PPE vs 67.5 +/- 15.6% without PPE, P<0.001) and the percentage of adequate compressions (67.7 +/- 18.9% with PPE vs 80.7 +/- 15.5% without PPE, P<0.001) were observed. Furthermore, the increases in heart rate, mean arterial pressure, and subjective fatigue score values were more obvious with the use of PPE (all P<0.01). We found significant deterioration of CC performance in HCW with the use of a level-C PPE, which may be a disadvantage for enhancing survival of cardiac arrest.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Realizing Optimal Chest Compression Fraction During Cardiopulmonary Resuscitation
    Talkington, Josh
    Dantu, Ram
    2016 IEEE FIRST INTERNATIONAL CONFERENCE ON CONNECTED HEALTH: APPLICATIONS, SYSTEMS AND ENGINEERING TECHNOLOGIES (CHASE), 2016, : 348 - 349
  • [22] Feasibility of automated rhythm assessment in chest compression pauses during cardiopulmonary resuscitation
    Ruiz, J.
    Ayala, U.
    de Gauna, S. Ruiz
    Irusta, U.
    Gonzalez-Otero, D.
    Alonso, E.
    Kramer-Johansen, J.
    Eftestol, T.
    RESUSCITATION, 2013, 84 (09) : 1223 - 1228
  • [23] Transthoracic impedance for the monitoring of quality of manual chest compression during cardiopulmonary resuscitation
    Zhang, Hehua
    Yang, Zhengfei
    Huang, Zitong
    Chen, Bihua
    Zhang, Lei
    Li, Heng
    Wu, Baoming
    Yu, Tao
    Li, Yongqin
    RESUSCITATION, 2012, 83 (10) : 1281 - 1286
  • [24] Impact of Personal Protective Equipment on Pediatric Cardiopulmonary Resuscitation Performance A Controlled Trial
    Donoghue, Aaron J.
    Kou, Maybelle
    Good, Grace L.
    Eiger, Carmel
    Nash, Mark
    Henretig, Fred M.
    Stacks, Helen
    Kochman, Adam
    Debski, Julie
    Chen, Jia-Yuh
    Sharma, Gaurav
    Hornik, Christoph P.
    Gosnell, Leigh
    Siegel, David
    Krug, Steven
    Adler, Mark D.
    PEDIATRIC EMERGENCY CARE, 2020, 36 (06) : 267 - 273
  • [25] Effects of personal protective equipment on cardiopulmonary resuscitation quality and outcomes: A systematic review
    Chung, Sung Phil
    Nehme, Ziad
    Johnson, Nicholas J.
    Lagina, Anthony
    Bray, Janet
    RESUSCITATION PLUS, 2023, 14
  • [26] Comparison of two infant chest compression techniques during simulated newborn cardiopulmonary resuscitation performed by a single rescuer: A randomized, crossover multicenter trial
    Smereka, Jacek
    Madziala, Marcin
    Szarpak, Lukasz
    CARDIOLOGY JOURNAL, 2019, 26 (06) : 761 - 768
  • [27] IQ-CPR Meter for Chest Compression Monitoring During Simulated Cardiopulmonary Resuscitation; a Comparative Study
    Phattharapornjaroen, Phatthranit
    Surapornpaiboon, Suwitchaya
    Chalermdamrichai, Phanorn
    Sittichanbuncha, Yuwares
    Sawanyawisuth, Kittisak
    ARCHIVES OF ACADEMIC EMERGENCY MEDICINE, 2020, 8 (01)
  • [28] Computed tomography during cardiopulmonary resuscitation using automated chest compression devices-an initial study
    Wirth, Stefan
    Koerner, Markus
    Treitl, Marcus
    Linsenmaier, Ulrich
    Leidel, Bernd A.
    Jaschkowitz, Thomas
    Reiser, Maximilian F.
    Kanz, Karl G.
    EUROPEAN RADIOLOGY, 2009, 19 (08) : 1857 - 1866
  • [29] Improvement in chest compression quality using a feedback device (CPRmeter): a simulation randomized crossover study
    Buleon, Clement
    Parienti, Jean-Jacques
    Halbout, Laurent
    Arrot, Xavier
    Regent, Helene De Facq
    Chelarescu, Dan
    Fellahi, Jean-Luc
    Gerard, Jean-Louis
    Hanouz, Jean-Luc
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2013, 31 (10) : 1457 - 1461
  • [30] Effect of the rate of chest compression familiarised in previous training on the depth of chest compression during metronome-guided cardiopulmonary resuscitation: a randomised crossover trial
    Bae, Jinkun
    Chung, Tae Nyoung
    Je, Sang Mo
    BMJ OPEN, 2016, 6 (02):