Proximal humeral internal locking system (PHILOS) for the treatment of proximal humeral fractures

被引:90
作者
Charalambous, C. P.
Siddique, I.
Valluripalli, K.
Kovacevic, M.
Panose, P.
Srinivasan, M.
Marynissen, H.
机构
[1] Burnley Gen Hosp, Dept Trauma & Orthopaed, Burnley, Lancs, England
[2] Blackburn Royal Infirm, Dept Trauma & Orthopaed, Manchester, Lancs, England
关键词
humerus; fracture fixation; internal; complications;
D O I
10.1007/s00402-006-0256-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction The aim of this study was to describe early results of a new internal locking system, PHILOS, used for the treatment of proximal humeral fractures. Materials and methods A chart and radiographic review of 25 cases that had proximal humeral internal locking system (PHILOS) plate for the treatment of proximal humeral fractures was performed. Results Of the 25 cases, 20 went to union with a mean neck/shaft angle of 127.2 degrees. Five cases required or were considered for revision surgery for non-union or implant failure. Of the 25 implants, 4 had screw protrusion into the gleno-humeral joint, 4 had screw loosening and backing out, and 1 plate broke without further trauma. Conclusions Our results suggest that PHILOS is an effective system for providing fracture stabilisation to bony union but awareness of potential hardware complications is essential.
引用
收藏
页码:205 / 210
页数:6
相关论文
共 16 条
[1]   Treatment of proximal humeral fractures with Polarus nail fixation [J].
Agel, J ;
Jones, CB ;
Sonzone, AG ;
Camuso, M ;
Henley, MB .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2004, 13 (02) :191-195
[2]   Early failure of intramedullary nailing for proximal humeral fractures [J].
Bernard, J ;
Charalambides, C ;
Aderinto, J ;
Mok, D .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2000, 31 (10) :789-792
[3]   Early experience with the PlantTan Fixator Plate for 2 and 3 part fractures of the proximal humerus [J].
Burton, DJC ;
Wells, G ;
Watters, A ;
Schilders, E ;
Venkateswaran, B .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2005, 36 (10) :1190-1196
[4]   Innovations in locking plate technology [J].
Haidukewych, GJ .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2004, 12 (04) :205-212
[5]   Rigid internal fixation of fractures of the proximal humerus in older patients [J].
Hintermann, B ;
Trouillier, HH ;
Schäfer, D .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (08) :1107-1112
[6]   THE NORMAL GLENOHUMERAL RELATIONSHIPS - AN ANATOMICAL STUDY OF 140 SHOULDERS [J].
IANNOTTI, JP ;
GABRIEL, JP ;
SCHNECK, SL ;
EVANS, BG ;
MISRA, S .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (04) :491-500
[7]   PLATE FIXATION OF PROXIMAL HUMERAL FRACTURES [J].
KRISTIANSEN, B ;
CHRISTENSEN, SW .
ACTA ORTHOPAEDICA SCANDINAVICA, 1986, 57 (04) :320-323
[8]   Mid term results of PlantTan plate in the treatment of proximal humerus fractures [J].
Machani, B ;
Sinopidis, C ;
Brownson, P ;
Papadopoulos, P ;
Gibson, J ;
Frostick, SP .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2006, 37 (03) :269-276
[10]   Backgrounds of the technology of internal fixators [J].
Perren, SM .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2003, 34 :1-3