The effect of breast support on upper body muscle activity during 5 km treadmill running

被引:13
作者
Milligan, Alexandra [1 ]
Mills, Chris [1 ]
Scurr, Joanna [1 ]
机构
[1] Univ Portsmouth, Dept Sport & Exercise Sci, Portsmouth PO1 2ER, Hants, England
关键词
Electromyography; Sports bra; Female runners; LOWER-LIMB; ACTIVATION; POSITION; KINETICS; SURFACE; SIZE;
D O I
10.1016/j.humov.2014.06.001
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Breast support has previously been shown to influence surface EMG of the pectoralis major during running. Reductions in muscle activity have previously been associated with a reduction in energy cost, which may be advantageous for female runners. Ten female participants performed two self-paced (average pace 9 km h(-1)) 5 km treadmill runs under two breast support conditions (low and high); an additional bare-breasted 2 min run was also conducted. Surface EMG electrodes were positioned on the pectoralis major, anterior deltoid, medial deltoid, and upper trapezius, with data collected during the first 2 mm of running and each kilometer interval thereafter. Reductions in peak EMG of the pectoralis major, anterior and medial deltoid were reported when participants ran in the high breast support during the initial intervals of the run (up to the second kilometer). The increased activation in the pectoralis major, anterior and medial deltoid in the low breast support may be due to increased tension within these muscles, induced by the greater breast pain experienced in the low breast support. This may be a strategy to reduce the independent breast movement causing the pain through increased muscular activation. This study further promotes the use of a high breast support during running with potential benefits for treadmill running associated with reductions in muscular demand during a 5 km run. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:74 / 83
页数:10
相关论文
共 38 条
  • [1] [Anonymous], 1985, Muscle alive: their functions revealed by electromyography
  • [2] Interpretation of EMG integral or RMS and estimates of "neuromuscular efficiency" can be misleading in fatiguing contraction
    Arabadzhiev, Todor I.
    Dimitrov, Vladimir G.
    Dimitrova, Nonna A.
    Dimitrov, George V.
    [J]. JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2010, 20 (02) : 223 - 232
  • [3] PATTERN OF MUSCULAR ACTIVITY DURING ARM SWING OF NATURAL WALKING
    BALLESTEROS, ML
    BUCHTHAL, F
    ROSENFALCK, P
    [J]. ACTA PHYSIOLOGICA SCANDINAVICA, 1965, 63 (03): : 296 - +
  • [4] Bennett M., 2009, THESIS BOISE STATE U
  • [5] Posterior glenohumeral subluxation: Active and passive stabilization in a biomechanical model
    Blasier, RB
    Soslowsky, LJ
    Malicky, DM
    Palmer, ML
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (03) : 433 - 440
  • [6] Boschma A. C., 1995, THESIS OREGON STATE
  • [7] Normalisation of gait EMGs: a re-examination
    Burden, AM
    Trew, M
    Baltzopoulos, V
    [J]. JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2003, 13 (06) : 519 - 532
  • [8] The use of surface electromyography in biomechanics
    De Luca, CJ
    [J]. JOURNAL OF APPLIED BIOMECHANICS, 1997, 13 (02) : 135 - 163
  • [9] Field A., 2009, Discovering statistics with SPSS, V3rd
  • [10] Averaged EMG profiles in jogging and running at different speeds
    Gazendam, Marnix G. J.
    Hof, At L.
    [J]. GAIT & POSTURE, 2007, 25 (04) : 604 - 614