A sol-gel method was employed to fabricate a poly(methyl methacrylate) (PMMA) electrophoresis microchip that contains a hydrophilic channel wall. To fabricate such a device, tetraethoxysilane (TEOS) was injected into the PMMA channel and was allowed to diffuse into the surface layer for 24 h. After removing the excess TEOS, the channel was filled with an acidic solution for 3 h. Subsequently, the channel was flushed with water and was pretreated in an oven to obtain a sol-gel-modified PMMA mi-crochip. The water contact angle for the sol-gel-modified PMMA was approximate to 27.4 degrees compared with approximate to 66.3 degrees for the pure PMMA. In addition, the electro-osmotic flow increased from 2.13 x 10(-4) cm(2) V-1 s(-1) for the native-PMMA channel to 4.86 x 10(-4) cm(2) V-1 s(-1) for the modified one. The analytical performance of the sol-gel-modifiedPMMA microchip was demonstrated for the electrophoretic separation of several purines, coupled with amperometric detection. The separation efficiency of uric acid increased to 74 882.3 m(-1) compared with 14730.5 m(-1) for native-PMMA microchips. The result of this simple modification is a significant improvement in the performance of PMMA for microchip electrophoresis and microfluidic applications.
引用
收藏
页码:6461 / 6467
页数:7
相关论文
共 35 条
[1]   Micro total analysis systems. 2. Analytical standard operations and applications [J].
Auroux, PA ;
Iossifidis, D ;
Reyes, DR ;
Manz, A .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2637-2652
[2]   Photo-induced synthesis of amorphous SiO2 film from tetramethoxy-silane on polymethylmethacrylate at room temperature [J].
Awazu, K ;
Onuki, H .
JOURNAL OF NON-CRYSTALLINE SOLIDS, 1997, 215 (2-3) :176-181
[3]  
Becker H, 2000, ELECTROPHORESIS, V21, P12, DOI 10.1002/(SICI)1522-2683(20000101)21:1<12::AID-ELPS12>3.0.CO
[4]  
2-7
[5]   Polymer microfluidic devices [J].
Becker, H ;
Locascio, LE .
TALANTA, 2002, 56 (02) :267-287
[6]   Effects of heat treatment on the properties of poly(methyl methacrylate)/silica hybrid materials prepared by sol-gel process [J].
Chan, CK ;
Peng, SL ;
Chu, IM ;
Ni, SC .
POLYMER, 2001, 42 (09) :4189-4196
[7]   Fabrication and performance of a three-dimensionally adjustable device for the amperometric detection of microchip capillary electrophoresis [J].
Chen, G ;
Bao, HM ;
Yang, PY .
ELECTROPHORESIS, 2005, 26 (24) :4632-4640
[8]   Ultrafast analysis of oligosaccharides on microchip with light-emitting diode confocal fluorescence detection [J].
Dang, F ;
Zhang, L ;
Hagiwara, H ;
Mishina, Y ;
Baba, Y .
ELECTROPHORESIS, 2003, 24 (04) :714-721
[9]   Micro total analysis systems. Latest advancements and trends [J].
Dittrich, Petra S. ;
Tachikawa, Kaoru ;
Manz, Andreas .
ANALYTICAL CHEMISTRY, 2006, 78 (12) :3887-3907
[10]   Wall coating for capillary electrophoresis on microchips [J].
Dolník, V .
ELECTROPHORESIS, 2004, 25 (21-22) :3589-3601