Subnanoliter enzymatic assays on microarrays

被引:35
作者
Angenendt, P [1 ]
Lehrach, H [1 ]
Kreutzberger, J [1 ]
Glökler, J [1 ]
机构
[1] Max Planck Inst Mol Genet, Berlin, Germany
关键词
drug screening; enzymatic assay; metagenomics; multiple spotting technique; protein microarray;
D O I
10.1002/pmic.200400955
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Many areas of research today are based on enzymatic assays most of which are still performed as enzyme-linked immunosorbent assays in microtiter plates. The demand for highly parallel screening of thousands of samples eventually led to a miniaturization and automation of these assays. However, the final transfer of enzymatic assays from a microtiter-based technology to microarrays has proven to be difficult for various reasons, such as the inability to maintain unbound reaction products on the spot of reaction or the missing capability of multiplexing. Here, we have conducted multiplex enzymatic assays in subnanoliter volumes on a single microarray using the multiple spotting technology. We were able to measure enzymatic activity with a sensitivity down to 35 enzyme molecules, applying only conventional flat microarray surfaces and standard microarray hardware. We have performed assays of inhibition and applied this format for the detection of prognostic markers, such as cathepsin D. The new approach allows the rapid and multiplex screening of thousands of samples on a single microarray with applications in drug screening, metagenomics, and high-throughput enzyme assays.
引用
收藏
页码:420 / 425
页数:6
相关论文
共 29 条
[1]   Seeing better through a MIST: Evaluation of monoclonal recombinant antibody fragments on microarrays [J].
Angenendt, P ;
Wilde, J ;
Kijanka, G ;
Baars, S ;
Cahill, DJ ;
Kreutzberger, J ;
Lehrach, H ;
Konthur, Z ;
Glokler, J .
ANALYTICAL CHEMISTRY, 2004, 76 (10) :2916-2921
[2]   Cell-free protein expression and functional assay in nanowell chip format [J].
Angenendt, P ;
Nyarsik, L ;
Szaflarski, W ;
Glokler, J ;
Nierhaus, KH ;
Lehrach, H ;
Cahill, DJ ;
Lueking, A .
ANALYTICAL CHEMISTRY, 2004, 76 (07) :1844-1849
[3]   Next generation of protein microarray support materials:: Evaluation for protein and antibody microarray applications [J].
Angenendt, P ;
Glökler, J ;
Sobek, J ;
Lehrach, H ;
Cahill, DJ .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1009 (1-2) :97-104
[4]   3D protein microarrays:: Performing multiplex immunoassays on a single chip [J].
Angenendt, P ;
Glökler, J ;
Konthur, Z ;
Lehrach, H ;
Cahill, DJ .
ANALYTICAL CHEMISTRY, 2003, 75 (17) :4368-4372
[5]   Toward optimized antibody microarrays:: a comparison of current microarray support materials [J].
Angenendt, P ;
Glökler, J ;
Murphy, D ;
Lehrach, H ;
Cahill, DJ .
ANALYTICAL BIOCHEMISTRY, 2002, 309 (02) :253-260
[6]  
ANGENENDT P, 2004, METHOD MOL BIOL, V278, P123
[7]   Stopped-flow enzyme assays on a chip using a microfabricated mixer [J].
Burke, BJ ;
Regnier, FE .
ANALYTICAL CHEMISTRY, 2003, 75 (08) :1786-1791
[8]   Immunohistochemical expression of cathepsin D in meningiomas [J].
Castilla, EA ;
Prayson, RA ;
Abramovich, CM ;
Cohen, ML .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2003, 119 (01) :123-128
[9]   Developing a strategy for activity-based detection of enzymes in a protein microarray [J].
Chen, GYJ ;
Uttamchandani, M ;
Zhu, Q ;
Wang, G ;
Yao, SQ .
CHEMBIOCHEM, 2003, 4 (04) :336-339
[10]   A microchip-based enzyme assay for protein kinase A [J].
Cohen, CB ;
Chin-Dixon, E ;
Jeong, S ;
Nikiforov, TT .
ANALYTICAL BIOCHEMISTRY, 1999, 273 (01) :89-97