Overhead Transmission Line 750 kV Model with Bundle Wire

被引:0
|
作者
Glushkov, Daniil A. [1 ]
Zinovev, Kirill A. [2 ]
机构
[1] Ural Fed Univ, Ural Power Engn Inst, High Voltage Engn Dept, Ekaterinburg, Russia
[2] Ural Fed Univ, Power Energy Syst Dept, Ekaterinburg, Russia
关键词
bundle wire; bundle radius; transmission line; corona discharge; firing voltage of the corona discharge;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The power transmission line (TL) designer is faced with the problem of the possible corona discharge firing voltage assessment on the basis of the simple relationships, the designer should have the clear idea of the basic characteristics of the corona discharge, their dependences on the wire design and the bundle availability as well as the mutual influence of the present parameters. The model of the overhead transmission line (OHTL) with the bundle wire was designed just for the present purpose. The special attention was drawn to the approach to the model practical implementation. From the one hand the designers succeeded in the model simplification and from the other hand the present model is an accurate representation of the most significant characteristics of the corona discharge (physical phenomena during the corona discharge and their interrelations)
引用
收藏
页码:1152 / 1155
页数:4
相关论文
共 50 条
  • [21] Refinement of Wind Loads on Lattice Support Structures of the Intersystem Overhead Power Transmission Lines 750 kV
    Shevchenko, Yevgeny
    Nazim, Yaroslav
    Tanasoglo, Anton
    Garanzha, Igor
    INTERNATIONAL SCIENTIFIC CONFERENCE URBAN CIVIL ENGINEERING AND MUNICIPAL FACILITIES (SPBUCEMF-2015), 2015, 117 : 1028 - 1035
  • [22] Optimization of conductor transposition and configuration of insulated ground wire on overhead transmission line
    Cheng, Muyao
    Zhongguo Dianli/Electric Power, 2000, 33 (01): : 57 - 58
  • [23] Ageing of an ADSS Cable Sheath on a 132kV Overhead Transmission Line
    Rowland, S. M.
    Zhang, X.
    Kopsidas, K.
    2008 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2008, : 89 - 92
  • [24] Lightning overvoltage analysis and calculation of 330kV overhead transmission line
    Zhang Xiubin
    Wen Dingjun
    Sun Yaming
    Chen Honggang
    MECHATRONICS ENGINEERING, COMPUTING AND INFORMATION TECHNOLOGY, 2014, 556-562 : 1588 - 1591
  • [25] Electromagnetic field coupling to overhead wires: Comparison of wire antenna and transmission line model in the frequency and time domain
    Poljak, Dragan
    Doric, Vicko
    Antonijevic, Sinisa
    Drissi, Khalil El Khamlichi
    Kerroum, Kamal
    ICECOM 2007: 19TH INTERNATIONAL CONFERENCE ON APPLIED ELECTROMAGNETICS AND COMMUNICATIONS, CONFERENCE PROCEEDINGS, 2007, : 119 - 122
  • [26] Experimental research on hot-line work of 750 kV single compact power transmission line
    Hebei Electric Power Research Institute, Shijiazhuang 050021, China
    不详
    不详
    Gaodianya Jishu, 2009, 11 (2876-2880):
  • [27] Wire Break Protection System for 0.38 and 6 – 10 KV Overhead Power Transmission Lines
    Ershov A.M.
    Khlopova A.V.
    Sidorov A.I.
    Power Technology and Engineering, 2020, 54 (03) : 434 - 437
  • [28] Adding one group of arresters to replace parallel resistor in 750 kV transmission line
    State Key Lab. of Control and Simulation of Power Systems and Generation Equipments, Tsinghua University, Beijing 100084, China
    不详
    Gaodianya Jishu, 2008, 6 (1105-1109):
  • [29] Study of Configuration and Optimization for Interphase Spacers of 750kV Compact Transmission Line
    Zhu, Kuanjun
    Li, Xinmin
    POWER AND ENERGY ENGINEERING CONFERENCE 2010, 2010, : 731 - 736
  • [30] Research on protective relaying and single-phase reclosure of 750 kV transmission line
    Li, Bin
    Li, Yongli
    He, Jiali
    Zheng, Yuping
    Sheng, Kun
    Guo, Zheng
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2004, 28 (13): : 73 - 76