Japanese guideline for the oncology FDG-PET/CT data acquisition protocol: synopsis of Version 1.0

被引:39
作者
Fukukita, Hiroyoshi [1 ]
Senda, Michio [2 ]
Terauchi, Takashi [3 ]
Suzuki, Kazufumi [4 ]
Daisaki, Hiromitsu [3 ]
Matsumoto, Keiichi [5 ]
Ikari, Yasuhiko [2 ]
Hayashi, Masuo [6 ]
机构
[1] Natl Ctr Global Hlth & Med, Dept Radiol, Chiba 2728516, Japan
[2] Inst Biomed Res & Innovat, Kobe, Hyogo, Japan
[3] Natl Canc Ctr, Tokyo 104, Japan
[4] Dokkyo Med Univ Hosp, Dokkyo, Tochigi, Japan
[5] Kyoto Coll Med Sci, Kyoto, Japan
[6] Osaka Med Coll Hosp, Takatsuki, Osaka, Japan
关键词
Guideline; FDG-PET; Oncology; NEC; QC; PERFORMANCE-MEASUREMENTS; MODES; 2D;
D O I
10.1007/s12149-010-0377-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This synopsis outlines the Japanese guideline Version 1.0 for the data acquisition protocol of oncology FDG-PET/CT scans that was created by a joint task force of the Japanese Society of Nuclear Medicine Technology (JSNMT) and the Japanese Council of PET Imaging, and published in Kakuigaku-Gijutsu 29(2):195-235, 2009, in Japanese. The guideline aims at standardizing the PET image quality among facilities and different PET/CT scanner models by determining and/or evaluating the data acquisition condition in experiments using an IEC body phantom, as well as by proposing the criteria for human image quality evaluation using patient noise equivalent count (NEC), NEC density, and liver signal-to-noise ratio.
引用
收藏
页码:325 / 334
页数:10
相关论文
共 10 条
  • [1] Erdi YE, 2004, J NUCL MED, V45, P813
  • [2] Hentschel M, 2002, EUR J NUCL MED MOL I, V29, P1630
  • [3] Kemp BJ, 2006, J NUCL MED, V47, P1960
  • [4] Mawlawi O, 2004, J NUCL MED, V45, P1734
  • [5] MEJIA AA, 1991, J NUCL MED, V32, P699
  • [6] NEC Density and Liver ROI S/N Ratio for Image Quality Control of Whole-Body FDG-PET Scans: Comparison with Visual Assessment
    Mizuta, Tetsuro
    Senda, Michio
    Okamura, Terue
    Kitamura, Keishi
    Inaoka, Yuichi
    Takahashi, Munehiro
    Matsumoto, Keiichi
    Abe, Makoto
    Shimonishi, Yoshihiro
    Shiomi, Susumu
    [J]. MOLECULAR IMAGING AND BIOLOGY, 2009, 11 (06) : 480 - 486
  • [7] National Electrical Manufacturers Association, 2007, NEMA STAND PUBL NU, VNU 2-2007
  • [8] National Electrical Manufactures Association, 2001, NEMA STAND PUBL NU
  • [9] Surti S, 2004, J NUCL MED, V45, P1040
  • [10] Performance of the new generation of whole-body PET/CT scanners:: Discovery STE and discovery VCT
    Teraes, M.
    Tolvanen, T.
    Johansson, J. J.
    Williams, J. J.
    Knuuti, J.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 (10) : 1683 - 1692