Evaluation of chemiluminescence reagents for selective detection of reactive oxygen species

被引:74
|
作者
Yamaguchi, Shinya
Kishikawa, Naoya
Ohyama, Kaname
Ohba, Yoshihito [2 ]
Kohno, Maiko [3 ]
Masuda, Toshinobu [3 ]
Takadate, Akira [3 ]
Nakashima, Kenichiro
Kuroda, Naotaka [1 ]
机构
[1] Nagasaki Univ, Grad Sch Biomed Sci, Course Pharmaceut Sci, Nagasaki 8528521, Japan
[2] Nagasaki Int Univ, Fac Pharmaceut Sci, Nagasaki 8593298, Japan
[3] Daiichi Coll Pharmaceut Sci, Minami Ku, Fukuoka 8158511, Japan
关键词
Reactive oxygen species; Chemiluminescent probe; Screening; Acridinium ester; Superoxide dismutase; LUMINOL-DEPENDENT CHEMILUMINESCENCE; MCLA CHEMILUMINESCENCE; FLUORESCENCE PROBES; HYDROGEN-PEROXIDE; SINGLET OXYGEN; SUPEROXIDE; DERIVATIVES; GENERATION; ANALOGS; DAMAGE;
D O I
10.1016/j.aca.2010.03.025
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In order to evaluate the chemiluminescence (CL) reagents for selective detection of reactive oxygen species (ROS), we comprehensively measured the CL responses of 20 CL reagents (three luminol derivatives, two imidazopyrazinone derivatives, eight lophine derivatives, six acridinium ester derivatives andlucigenin) against six types of ROS (superoxide anion: O-2(center dot-), hydroxyl radical: (OH)-O-center dot, hydrogen peroxide: H2O2, hypochlorite anion: ClO-, singlet oxygen: O-1(2), and nitric oxide: NO). As a result of the screening, it was found that nine CL reagents selectively detected O-2(center dot-) while one CL reagent selectively detected (OH)-O-center dot. However, no CL reagent had selectivity on the detection of H2O2, ClO-, O-1(2) and NO. Our screening results could help to select the most suitable CL reagent for selective determination of different ROS. As an application study, 4-methoxyphenyl-10-methylacridinium-9-carboxylate (MMAC), one of the acridinium ester derivatives, showed high selectivity on the detection of O-2(center dot-), and thus was applied to the assay of superoxide dismutase (SOD) activity. The dynamic range and detection limit of the developed CL assay were 0.1-10 and 0.06 U mL(-1), respectively. Significant correlation (r = 0.997) was observed between the results by the CL assay using MMAC and the spectrophotometric assay using 2-(4-iodophenyl)-3-(4-nitrophenyl)-5-(2,4-disulfophenyl)-2H-tetrazolium monosodium salt. Crown Copyright (C) 2010 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:74 / 78
页数:5
相关论文
共 50 条
  • [21] Nanomaterial-based chemiluminescence systems for tracing of reactive oxygen species in biosensors
    Teng, Xu
    Qi, Ling
    Liu, Tao
    Li, Linhai
    Lu, Chao
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2023, 162
  • [22] ANTIOXIDANT ENZYME RESPONSE AND REACTIVE OXYGEN SPECIES PRODUCTION IN MARINE RAPHIDOPHYTES
    Portune, Kevin J.
    Cary, Stephen Craig
    Warner, Mark E.
    JOURNAL OF PHYCOLOGY, 2010, 46 (06) : 1161 - 1171
  • [23] Quantification of reactive oxygen species for photodynamic therapy
    Tan, Zou
    Zhang, Jinde
    Lin, Lishen
    Li, Buhong
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS VII, 2017, 0024
  • [24] Production and consumption of reactive oxygen species by fullerenes
    Kong, Lingjun
    Zepp, Richard G.
    ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 2012, 31 (01) : 136 - 143
  • [25] Detection of Oxidative Stress Induced by Nanomaterials in Cells-The Roles of Reactive Oxygen Species and Glutathione
    Capek, Jan
    Rousar, Tomas
    MOLECULES, 2021, 26 (16):
  • [26] Bioimaging Probes for Reactive Oxygen Species and Reactive Nitrogen Species
    Nagano, Tetsuo
    JOURNAL OF CLINICAL BIOCHEMISTRY AND NUTRITION, 2009, 45 (02) : 111 - 124
  • [27] CHEMICAL AND BIOCHEMICAL-STUDIES ON REACTIVITIES, FORMATIONS AND TOXICITIES OF REACTIVE OXYGEN SPECIES
    NAGANO, T
    YAKUGAKU ZASSHI-JOURNAL OF THE PHARMACEUTICAL SOCIETY OF JAPAN, 1991, 111 (02): : 103 - 119
  • [28] Chemiluminescence imaging of UVA induced reactive oxygen species in mouse skin using L-012 as a probe
    Liu, Jiao-Li
    Xue, Qiao
    Liu, Chen-Guang
    Bai, Feng-Wu
    Wada, Satoshi
    Wang, Jin-Ye
    FREE RADICAL RESEARCH, 2018, 52 (11-12) : 1424 - 1431
  • [29] Study of the electrochemically generated chemiluminescence of reactive oxygen species on indium tin oxide glass
    Zhao, Jinjin
    Guo, Wenying
    Li, Jingjing
    Chu, Haihong
    Tu, Yifeng
    ELECTROCHIMICA ACTA, 2012, 61 : 118 - 123
  • [30] Simultaneous use of electrochemistry and chemiluminescence to detect reactive oxygen species produced by human neutrophils
    Shleev, Sergey
    Wetteroe, Jonas
    Magnusson, Karl-Eric
    Ruzgas, Tautgirdas
    CELL BIOLOGY INTERNATIONAL, 2008, 32 (12) : 1486 - 1496