Additive concentration effects on enantioselective separations in supercritical fluid chromatography

被引:43
作者
Phinney, KW [1 ]
Sander, LC [1 ]
机构
[1] Natl Inst Stand & Technol, Div Analyt Chem, Chem Sci & Technol Lab, Gaithersburg, MD 20899 USA
关键词
chiral separations; chiral stationary phase; efficiency; enantiomers; retention;
D O I
10.1002/chir.10196
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Polar additive concentration effects in supercrifical fluid chromatography were studied on chiral stationary phases having either a macrocyclic glycopeptide or a derivatized polysaccharide as the chiral selector. Two basic additives, isopropylamine and triethylamine, were incorporated into the methanol modifier at various concentrations and the effects on retention, selectivity, and resolution were monitored. Many of the analytes failed to elute from the macrocyclic glycopeptide stationary phase in the absence of an additive and the most noticeable effect of increasing additive concentration was a significant decrease in retention. On the derivatized polysaccharide stationary phase the additives had little effect on retention, but they did foster significant improvements in peak shape and resolution.
引用
收藏
页码:287 / 294
页数:8
相关论文
共 23 条
[1]   MACROCYCLIC ANTIBIOTICS AS A NEW CLASS OF CHIRAL SELECTORS FOR LIQUID-CHROMATOGRAPHY [J].
ARMSTRONG, DW ;
TANG, YB ;
CHEN, SS ;
ZHOU, YW ;
BAGWILL, C ;
CHEN, JR .
ANALYTICAL CHEMISTRY, 1994, 66 (09) :1473-1484
[2]  
BEESLEY TE, 2001, CHIRAL SEPARATION TE, P25
[3]   EFFECT OF BASIC ADDITIVES ON PEAK SHAPES OF STRONG BASES SEPARATED BY PACKED-COLUMN SUPERCRITICAL FLUID CHROMATOGRAPHY [J].
BERGER, TA ;
DEYE, JF .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1991, 29 (07) :310-317
[4]   SEPARATION OF BENZENE POLYCARBOXYLIC ACIDS BY PACKED-COLUMN SUPERCRITICAL FLUID CHROMATOGRAPHY USING METHANOL CARBON-DIOXIDE MIXTURES WITH VERY POLAR ADDITIVES [J].
BERGER, TA ;
DEYE, JF .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1991, 29 (04) :141-146
[5]   ROLE OF ADDITIVES IN PACKED-COLUMN SUPERCRITICAL FLUID CHROMATOGRAPHY - SUPPRESSION OF SOLUTE IONIZATION [J].
BERGER, TA ;
DEYE, JF .
JOURNAL OF CHROMATOGRAPHY, 1991, 547 (1-2) :377-392
[6]   SEPARATION OF HYDROXYBENZOIC ACIDS BY PACKED-COLUMN SUPERCRITICAL FLUID CHROMATOGRAPHY USING MODIFIED FLUIDS WITH VERY POLAR ADDITIVES [J].
BERGER, TA ;
DEYE, JF .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1991, 29 (01) :26-30
[7]  
Berger TA., 1995, Packed Column SFC
[8]  
Blackwell JA, 1998, CHIRALITY, V10, P338, DOI 10.1002/(SICI)1520-636X(1998)10:4<338::AID-CHIR8>3.0.CO
[9]  
2-3
[10]   Effect of mobile phase additives in packed-column subcritical and supercritical fluid chromatography [J].
Blackwell, JA ;
Stringham, RW ;
Weckwerth, JD .
ANALYTICAL CHEMISTRY, 1997, 69 (03) :409-415