A discharge lamp model based on lamp dynamic conductance

被引:26
作者
Blanco, Cecilio [1 ]
Anton, Juan C.
Robles, Arturo
Ferrero, Francisco J.
Campo, Juan C.
Gonzalez, Manuela
Zissis, Georges
机构
[1] Univ Oviedo, Gijon 33204, Spain
[2] Univ Toulouse, LAPLACE, F-31062 Toulouse, France
关键词
conductance model; discharge lamp;
D O I
10.1109/TPEL.2007.897195
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A model for discharge lamp based on lamp electrical conductance is proposed. Physical assumptions are used to obtain this model. The model allows simulating lamp behavior at different frequencies and delivered power levels. The model has been verified using a high pressure sodium lamp supplied at 50 and 100 kHz.
引用
收藏
页码:727 / 734
页数:8
相关论文
共 24 条
[11]  
FOHL T, 1975, J IES JUL, P265
[12]  
Francis VJ, 1948, Fundamentals of discharge tube circuits, methuen
[13]  
HERRICK PR, 1980, IEEE T IND APPL, V16, P648, DOI 10.1109/TIA.1980.4503847
[14]  
*MATH WORKS INC, 2001, MATLAB OPT TOOLB US
[15]  
*MATH WORKS INC, 2001, SIMULINK DYN SYST SI
[16]  
*MATHW INC, 2000, MATLAB OPT TOOLB US
[17]  
MEYER C, 1988, DISCHARGE LAMPS
[18]   Predicted results of a HID DC current lamp considering a P-1 radiation model [J].
Paul, KC ;
Takemura, T ;
Matsuno, H ;
Hiramoto, T ;
Dawson, F ;
Gonzalez, JJ ;
Gleizes, A ;
Zissis, G ;
Erraki, A ;
Lavers, JD .
IEEE TRANSACTIONS ON PLASMA SCIENCE, 2004, 32 (01) :118-126
[19]  
TORRECILLAS R, 1980, THESIS U COMPLUTENSE
[20]  
von Engel A., 1965, IONIZED GASES