Long-Term Follow-Up of Early Cochlear Implant Device Activation

被引:17
作者
Bruschke, Stefanie [1 ]
Baumann, Uwe [1 ]
Stoever, Timo [2 ]
机构
[1] Goethe Univ Frankfurt, ENT Dept Audiol Acoust, Frankfurt, Germany
[2] Goethe Univ Frankfurt, ENT Dept, Frankfurt, Germany
关键词
Cochlear implant; Early cochlear implant device activation; Early fitting; Long-term follow-up; Follow-up effort; COMPLICATIONS; QUALITY; VERTIGO;
D O I
10.1159/000512760
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Background: The cochlear implant (CI) is a standard procedure for the treatment of patients with severe to profound hearing loss. In the past, a standard healing period of 3-6 weeks occurred after CI surgery before the sound processor was initially activated. Advancements of surgical techniques and instruments allow an earlier initial activation of the processor within 14 days after surgery. Objective: Evaluation of the early CI device activation after CI surgery within 14 days, comparison to the first activation after 4-6 weeks, and assessment of the feasibility and safety of the early fitting over a 12 month observation period were the objectives of this study. Method: In a prospective study, 127 patients scheduled for CI surgery were divided into early fitting group (EF, n = 67) and control group (CG, n = 60). Individual questionnaires were used to evaluate medical and technical outcomes of the EF. Medical side effects, speech recognition, and follow-up effort were compared with the CG within the first year after CI surgery. Results: The early fitting was feasible in 97% of the EF patients. In the EF, the processor was activated 25 days earlier than in the CG. No major complications were observed in either group. At the follow-up appointments, side effects such as pain and balance problems occurred with comparable frequency in both groups. At initial fitting, the EF showed a significantly higher incidence of medical minor complications (p < 0.05). When developing speech recognition within the first year of CI use, no difference was observed. Furthermore, the follow-up effort within the first year after CI surgery was comparable in both groups. Conclusions: Early fitting of the sound processor is a feasible and safe procedure with comparable follow-up effort. Although more early minor complications were observed in the EF, there were no long-term wound healing problems caused by the early fitting. Regular inspection of the magnet strength is recommended as part of the CI follow-up since postoperative wound swelling must be expected. The early fitting procedure enabled a clear reduction in the waiting time between CI surgery and initial sound processor activation.
引用
收藏
页码:327 / 337
页数:11
相关论文
共 24 条
[1]   Cochlear Implant Device Activation and Programming: 5 Days Postimplantation [J].
Alsabellha, Rabea M. ;
Hagr, Abdulrahman ;
Al-momani, Murad O. ;
Garadat, Soha N. .
OTOLOGY & NEUROTOLOGY, 2014, 35 (04) :E130-E134
[2]   Is Early Cochlear Implant Device Activation Safe for All on-the-Ear and off-the-Ear Sound Processors? [J].
Batuk, Merve Ozbal ;
Yarali, Mehmet ;
Cinar, Betul Cicek ;
Kocabay, Aysun Parlak ;
Bajin, Munir Demir ;
Sennaroglu, Gonca ;
Sennaroglu, Levent .
AUDIOLOGY AND NEURO-OTOLOGY, 2019, 24 (06) :279-284
[3]   Postoperative complications in cochlear implants: a retrospective analysis of 438 consecutive cases [J].
Ciorba, A. ;
Bovo, R. ;
Trevisi, P. ;
Rosignoli, M. ;
Aimoni, C. ;
Castiglione, A. ;
Martini, A. .
EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2012, 269 (06) :1599-1603
[4]  
Craddock Louise, 2016, Cochlear Implants Int, V17 Suppl 1, P26, DOI 10.1080/14670100.2016.1161122
[5]   Headache and Degraded Speech Recognition in a Patient with unilateral Cochlear Implant [J].
Gaertner, L. ;
Lesinski-Schiedat, A. ;
Buechner, A. ;
Lenarz, T. .
LARYNGO-RHINO-OTOLOGIE, 2016, 95 (08) :559-560
[6]   A NEW INCISION FOR PLACEMENT OF COCHLEAR IMPLANTS [J].
GIBSON, WPR ;
HARRISON, HC ;
PROWSE, C .
JOURNAL OF LARYNGOLOGY AND OTOLOGY, 1995, 109 (09) :821-825
[7]   Early Fitting in Cochlear Implantation: Benefits and Limits [J].
Guenther, Stefanie ;
Baumann, Uwe ;
Stoever, Timo .
OTOLOGY & NEUROTOLOGY, 2018, 39 (04) :E250-E256
[8]   Feasibility of one-day activation in cochlear implant recipients [J].
Hagr, Abdulrahman ;
Garadat, Soha N. ;
Al-Momani, Murad ;
Alsabellha, Rabea M. ;
Almuhawas, Fida A. .
INTERNATIONAL JOURNAL OF AUDIOLOGY, 2015, 54 (05) :323-328
[9]  
Hoppe U, 2017, HNO, V65, P546, DOI 10.1007/s00106-016-0226-7
[10]  
Kempf HG., 1999, LARYNGORHINOOTOLOGIE, V78, P527