A feature-guided, focused 3D signal permutation method for subtomogram averaging

被引:5
|
作者
Peters, John Jacob [1 ,2 ,3 ,4 ,5 ]
Leitz, Jeremy [1 ,2 ,3 ,4 ,5 ]
Guo, Qiang [6 ,7 ,8 ]
Beck, Florian [9 ]
Baumeister, Wolfgang [8 ]
Brunger, Axel T. [1 ,2 ,3 ,4 ,5 ]
机构
[1] Stanford Univ, Dept Mol & Cellular Physiol, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Neurol & Neurol Sci, Stanford, CA 94305 USA
[3] Stanford Univ, Dept Struct Biol, Stanford, CA 94305 USA
[4] Stanford Univ, Dept Photon Sci, Stanford, CA 94305 USA
[5] Stanford Univ, Howard Hughes Med Inst, Stanford, CA 94305 USA
[6] Peking Univ, Sch Life Sci, State Key Lab Prot & Plant Gene Res, Beijing 100871, Peoples R China
[7] Peking Univ, Peking Tsinghua Ctr Life Sci, Beijing 100871, Peoples R China
[8] Max Planck Inst Biochem, Dept Biol Struct, D-82152 Martinsried, Germany
[9] Max Planck Inst Biochem, CryoEM Technol, D-82152 Martinsried, Germany
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
Cryo-electron tomography; In situ cellular tomography; Subtomogram averaging; Feature-guided alignment; 3D signal subtraction; TOMOGRAPHY; IMPLEMENTATION; RESOLUTION; ALIGNMENT; ANGSTROM; TOOLBOX; COMPLEX;
D O I
10.1016/j.jsb.2022.107851
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Advances in electron microscope instrumentation, cryo-electron tomography data collection, and subtomogram averaging have allowed for the in-situ visualization of molecules and their complexes in their native environment. Current data processing pipelines commonly extract subtomograms as a cubic subvolume with the key assumption that the selected object of interest is discrete from its surroundings. However, in instances when the object is in its native environment, surrounding densities may negatively affect the subsequent alignment and refinement processes, leading to loss of information due to misalignment. For example, the strong densities from surrounding membranes may dominate the alignment process for membrane proteins. Here, we developed methods for feature-guided subtomogram alignment and 3D signal permutation for subtomogram averaging. Our 3D signal permutation method randomizes and filters voxels outside a mask of any shape and blurs the boundary of the mask that encapsulates the object of interest. The randomization preserves global statistical properties such as mean density and standard deviation of voxel density values, effectively producing a featureless background surrounding the object of interest. This signal permutation process can be repeatedly applied with intervening alignments of the 3D signal-permuted subvolumes, recentering of the mask, and optional adjustments of the shape of the mask. We have implemented these methods in a new processing pipeline which starts from tomograms, contains feature-guided subtomogram extraction and alignment, 3D signal-permutation, and subtomogram visualization tools. As an example, feature-guided alignment and 3D signal permutation leads to improved subtomogram average maps for a dataset of synaptic protein complexes in their native environment.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Gum-Net: Unsupervised Geometric Matching for Fast and Accurate 3D Subtomogram Image Alignment and Averaging
    Zeng, Xiangrui
    Xu, Min
    2020 IEEE/CVF CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2020, : 4072 - 4083
  • [2] Efficient 3D-CTF correction for cryo-electron tomography using NovaCTF improves subtomogram averaging resolution to 3.4 Å
    Turonova, Beata
    Schur, Florian K. M.
    Wan, William
    Briggs, John A. G.
    JOURNAL OF STRUCTURAL BIOLOGY, 2017, 199 (03) : 187 - 195
  • [3] Assessment of scoring functions to rank the quality of 3D subtomogram clusters from cryo-electron tomography
    Singla, Jitin
    White, Kate L.
    Stevens, Raymond C.
    Alber, Frank
    JOURNAL OF STRUCTURAL BIOLOGY, 2021, 213 (02)
  • [4] Simulation-Guided 3D Nanomanufacturing via Focused Electron Beam Induced Deposition
    Fowlkes, Jason D.
    Winkler, Robert
    Lewis, Brett B.
    Stanford, Michael G.
    Plank, Harald
    Rack, Philip D.
    ACS NANO, 2016, 10 (06) : 6163 - 6172
  • [5] Resolution improvement by 3D particle averaging in localization microscopy
    Broeken, Jordi
    Johnson, Hannah
    Lidke, Diane S.
    Liu, Sheng
    Nieuwenhuizen, Robert P. J.
    Stallinga, Sjoerd
    Lidke, Keith A.
    Rieger, Bernd
    METHODS AND APPLICATIONS IN FLUORESCENCE, 2015, 3 (01):
  • [6] Methods for aligning and for averaging 3D volumes with missing data
    Schmid, Michael F.
    Booth, Christopher R.
    JOURNAL OF STRUCTURAL BIOLOGY, 2008, 161 (03) : 243 - 248
  • [7] Advances in 3D focused ion beam tomography
    Cantoni, Marco
    Holzer, Lorenz
    MRS BULLETIN, 2014, 39 (04) : 354 - 360
  • [8] Efficient 3D interpolation method for 3D reconstruction
    Joung, SC
    Jang, YH
    Hwang, IY
    Kim, SJ
    Paik, JK
    THREE-DIMENSIONAL IMAGE CAPTURE AND APPLICATIONS IV, 2001, 4298 : 203 - 210
  • [9] 3D Clifford Analytic Signal for 3D Envelope Detection on Ultrasound Volume
    Wang, Liang
    Girard, Patrick R.
    Clarysse, Patrick
    Delachartre, Philippe
    INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS 2021), 2021,
  • [10] 3D particle averaging and detection of macromolecular symmetry in localization microscopy
    Heydarian, Hamidreza
    Joosten, Maarten
    Przybylski, Adrian
    Schueder, Florian
    Jungmann, Ralf
    van Werkhoven, Ben
    Keller-Findeisen, Jan
    Ries, Jonas
    Stallinga, Sjoerd
    Bates, Mark
    Rieger, Bernd
    NATURE COMMUNICATIONS, 2021, 12 (01)