EFFECTS OF HIGH-VELOCITY, LOW-AMPLITUDE SPINAL MANIPULATION ON STRENGTH AND THE BASAL TONUS OF FEMALE PELVIC FLOOR MUSCLES

被引:21
作者
Nogueira de Almeida, Berta Simon [1 ]
Sabatino, Jose Hugo [1 ]
Giraldo, Paulo Cesar [1 ]
机构
[1] Univ Estadual Campinas, UNICAMP, Dept Gynecol, BR-13092400 Campinas, SP, Brazil
关键词
Pelvic Floor; Perineum; Manipulation; Spinal; Muscle Tonus; Muscular Contraction; LOW-BACK-PAIN; THRUST MANIPULATION; SACROILIAC JOINT; AUDIBLE POP; GAIT; INCONTINENCE; INHIBITION; EXERCISE; NECK;
D O I
10.1016/j.jmpt.2009.12.007
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Objective: Spinal manipulation with high-velocity and low-amplitude (HVLA) manipulation is frequently used for the treatment of lumbopelvic pain; however, the effect on the pelvic floor has been poorly studied in the past. The objective of this study was to quantify the intravaginal pressure (IVP) and the basal perineal tonus (BPT), measured in terms of pressure, before and after the HVLA manipulation in patients without neuromuscular and skeletal dysfunctions. Methods: In this experimental, noncontrolled, nonrandomized study, IVP was obtained through a perineometer introduced into the volunteers' vagina while in dorsal horizontal decubitus. Forty young, healthy university volunteer women with no history of vaginal delivery participated. All voluntary contractions of the perineal muscles were measured in 3 different ways: phasic perineal contraction (PPC), tonic perineal contraction, and perineal contraction associated to accessory muscles. New pressure measurements were obtained immediately after the HVLA manipulation on the volunteers' sacrum. The pressures were registered and transcribed directly to a personal computer with specific software. Results: The average IVPs obtained in millimeters of mercury before and after the HVLA manipulation were 56.01 (+/- 25.54) and 64.65 (+/- 25.63) for PPC, 445.90 (+/- 186.84) and 483.14 (+/- 175.29) for tonic perineal contraction, and 65.62 (+/- 26.56) and 69.37 (+/- 25.26) for perineal contraction associated to accessory muscles, respectively. There was significant statistical variation only for PPC (P = .0020) values. The BPT increased regardless of the type of contraction (P < .05). Conclusion: High-velocity and low-amplitude manipulation of the sacrum was associated with an increase of PPC and of BPT in women who had no associated osteoarticular diseases. These preliminary discoveries could be helpful in the future study of the treatment of women with perineal hypotony. (J Manipulative Physiol Ther 2010;33:109-116)
引用
收藏
页码:109 / 116
页数:8
相关论文
共 33 条
[1]   Treatment of urinary stress incontinence by intravaginal electrical stimulation and pelvic floor physiotherapy [J].
Amaro, JL ;
Gameiro, MOO ;
Padovani, CR .
INTERNATIONAL UROGYNECOLOGY JOURNAL, 2003, 14 (03) :204-208
[2]  
[Anonymous], 1986, Vertebral Manipulation
[3]  
Bachmann GA, 2006, J REPROD MED, V51, P447
[4]  
Bernardes N. O., 2000, REV BRAS GINECOL OBS, V22, P49
[5]   Is there any difference in measurement of pelvic floor muscle strength in supine and standing position? [J].
Bo, K ;
Finckenhagen, HB .
ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2003, 82 (12) :1120-1124
[6]   PELVIC FLOOR MUSCLE EXERCISE FOR THE TREATMENT OF FEMALE STRESS URINARY-INCONTINENCE .2. VALIDITY OF VAGINAL PRESSURE MEASUREMENTS OF PELVIC FLOOR MUSCLE STRENGTH AND THE NECESSITY OF SUPPLEMENTARY METHODS FOR CONTROL OF CORRECT CONTRACTION [J].
BO, K ;
KVARSTEIN, B ;
HAGEN, RR ;
LARSEN, S .
NEUROUROLOGY AND URODYNAMICS, 1990, 9 (05) :479-487
[7]   CHANGES IN INNOMINATE TILT AFTER MANIPULATION OF THE SACROILIAC JOINT IN PATIENTS WITH LOW-BACK PAIN - AN EXPERIMENTAL-STUDY [J].
CIBULKA, MT ;
DELITTO, A ;
KOLDEHOFF, RM .
PHYSICAL THERAPY, 1988, 68 (09) :1359-1363
[8]   The Audible Pop from Thoracic Spine Thrust Manipulation and Its Relation to Short-Term Outcomes in Patients with Neck Pain [J].
Cleland, Joshua ;
Flynn, Timothy ;
Childs, John ;
Eberhart, Sarah .
JOURNAL OF MANUAL & MANIPULATIVE THERAPY, 2007, 15 (03) :143-154
[9]  
Dishman J D, 2001, Electromyogr Clin Neurophysiol, V41, P97
[10]   The effects of cervical high-velocity low-amplitude thrust manipulation on resting electromyographic activity of the biceps brachii muscle [J].
Dunning, James ;
Rushton, Alison .
MANUAL THERAPY, 2009, 14 (05) :508-513