Analysis and modeling of a proportional directional valve with nonlinear solenoid

被引:27
作者
Zhu, Yaguang [1 ]
Jin, Bo [2 ]
机构
[1] Changan Univ, Key Lab Rd Construct Technol & Equipment, Xian 710064, Peoples R China
[2] Zhejiang Univ, State Key Lab Fluid Power Transmiss & Control, Hangzhou 310027, Peoples R China
基金
中国国家自然科学基金;
关键词
Nonlinear characteristic; Frequency response; Modeling; Proportional directional valve; SIMULATION;
D O I
10.1007/s40430-015-0464-8
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
To explain the influence of the nonlinear characteristic of a proportional directional valve with double solenoids, a dynamic model with a nonlinear performance in current-force-displacement of double solenoids proportional valve is presented. Despite the analyzing of nonlinear characteristic of the solenoids, the valve spool modeling, the orifice area and the dynamic model of the valve are also presented. The simulation model is set in MATLAB and a test rig is built for the dynamic performance test. At last, the comparison in sine wave and dynamic response of the simulation and the experiments are made. A big distortion occurs near zero spool position because the nonlinear characteristic is mainly manifested when the solenoid current is small. And it is mainly induced by the nonlinear characteristic of the solenoids and the direction switch motion of spool. The output in simulation is almost coincided with that of experimental result. That means the proposed modeling method of solenoids and valve is valid and effective. Some advanced control theories and methods can be applied simultaneously.
引用
收藏
页码:507 / 514
页数:8
相关论文
共 16 条
[1]   Flow forces analysis of an open center hydraulic directional control valve sliding spool [J].
Amirante, R ;
Del Vescovo, G ;
Lippolis, A .
ENERGY CONVERSION AND MANAGEMENT, 2006, 47 (01) :114-131
[2]   Dynamic analysis of proportional solenoid controlled piloted relief valve by bondgraph [J].
Dasgupta, K ;
Watton, J .
SIMULATION MODELLING PRACTICE AND THEORY, 2005, 13 (01) :21-38
[3]  
Del Vescovo G., 2001, P 3 INT C MINIHYDRO
[4]  
Devarajan D, 2003, BMAS 2003: PROCEEDINGS OF THE 2003 IEEE INTERNATIONAL WORKSHOP ON BEHAVIORAL MODELING AND SIMULATION, P76
[5]   A parsimonious model for the proportional control valve [J].
Elmer, KF ;
Gentle, CR .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2001, 215 (11) :1357-1363
[6]   Unified modeling and analysis of a proportional valve [J].
Eryilmaz, B ;
Wilson, BH .
JOURNAL OF THE FRANKLIN INSTITUTE-ENGINEERING AND APPLIED MATHEMATICS, 2006, 343 (01) :48-68
[7]  
Jin Bo, 2013, Applied Mechanics and Materials, V325-326, P1166, DOI 10.4028/www.scientific.net/AMM.325-326.1166
[8]  
Kong Xiang-bing, 2007, Electric Machines and Control, V11, P408
[9]   Multi-domain modeling and simulation of proportional solenoid valve [J].
Liu Yan-fang ;
Dai Zhen-kun ;
Xu Xiang-yang ;
Tian Liang .
JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2011, 18 (05) :1589-1594
[10]  
Mauri D, 2013, 22 INT C MECH ENG CO, P2772