Intermediate term evaluation of the Eclypse distal radio-ulnar prosthesis for rheumatoid arthritis. A report of five cases

被引:6
作者
Bigorre, N. [1 ]
Saint Cast, Y. [1 ]
Cesari, B. [1 ]
Rabarin, F. [1 ]
Raimbeau, G. [1 ]
机构
[1] Village Sante Angers Loire, Ctr Main, 47 Rue Foucaudiere, F-49800 Trelaze, France
关键词
Wrist; Distal radio-ulnar joint; Hemi-arthroplasty; Pyrocarbon spacer; Rheumatoid arthritis; ULNAR HEAD ENDOPROSTHESIS; JOINT; ARTHROPLASTY; IMPINGEMENT; RESECTION;
D O I
10.1016/j.otsr.2016.01.012
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Hypothesis: Early medical management of rheumatoid arthritis with biotherapy has changed the traditional musculoskeletal damage from this disease. When the distal radio-ulnar joint (DRUJ) is involved, classic procedures may be inappropriate. We chose a hemi-arthroplasty of the DRUJ joint (Eclypse(TM)) in patients with persistent synovitis and chondrolysis with a stable joint. The aim of this study was to assess the intermediate term results of this approach in these specific cases. Materials and methods: We report a retrospective study of 5 Eclypse arthropasties implanted between March 2005 and March 2011. There were 4 women and 1 man, mean age: 58.4 years old (54-62) with RA that had been present for 21.6 years (15-33). This hemi-arthroplasty replaced the ulnar head with a pyrocarbon component. Patients were evaluated by an independent observer for pain by VAS, range of motion, grip strength in the neutral position by Jamar dynamometer, pronation and supination strengths with a pronosupinator, DASH score and wrist X-rays. Results: One patient was lost to follow-up and the 4 others underwent a follow-up evaluation at 64 months (43-90). There were no intra-operative or postoperative complications. The pain score at the final follow-up was 1.5/10 (0-4), pronation was 70 degrees (60-80) and supination was 80 degrees (80-80). Grip strength was 148% compared to the contralateral side (73-200%). Pronation and supination strengths were 1.7 kg (1.5-2) and 2.1 kg (2-2.5) respectively. The DASH score was 55.9 points (42.6 to 79.3). X-rays did not show any changes in the ulnar notch. Conclusion: This distal radio-ulnar arthroplasty is less invasive and preserves the bone and ligaments. Clinical results are rapid, remain stable over time and are well tolerated. This arthroplasty, which was initially developed for osteoarthritis and traumatic lesions of the DRUJ, is promising for specific cases of rheumatoid arthritis. (c) 2016 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:345 / 349
页数:5
相关论文
共 34 条
  • [1] Backdahl M., 1903, ACTA RHEUMATOL SCA S, V5, P1
  • [2] ULNAR IMPINGEMENT SYNDROME
    BELL, MJ
    HILL, RJ
    MCMURTRY, RY
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1985, 67 (01): : 126 - 129
  • [3] Use of an ulnar head endoprosthesis for treatment of an unstable distal ulnar resection: Review of mechanics, indications, and surgical technique
    Berger, RA
    Cooney, WP
    [J]. HAND CLINICS, 2005, 21 (04) : 603 - +
  • [4] FAILED DISTAL ULNA RESECTIONS
    BIEBER, EJ
    LINSCHEID, RL
    DOBYNS, JH
    BECKENBAUGH, RD
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1988, 13A (02): : 193 - 200
  • [5] Bokros JC., 1969, Chemistry and Physics of Carbon, V5, P1
  • [6] DISTAL RADIOULNAR JOINT ARTHROPLASTY - THE HEMIRESECTION-INTERPOSITION TECHNIQUE
    BOWERS, WH
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1985, 10A (02): : 169 - 178
  • [7] EXTENSOR CARPI ULNARIS AND FLEXOR CARPI ULNARIS TENODESIS OF THE UNSTABLE DISTAL ULNA
    BREEN, TF
    JUPITER, JB
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1989, 14A (04): : 612 - 617
  • [8] CLAWSON MC, 1991, HAND CLIN, V7, P373
  • [9] WEAR CHARACTERISTICS OF THE CANINE ACETABULUM AGAINST DIFFERENT FEMORAL PROSTHESES
    COOK, SD
    THOMAS, KA
    KESTER, MA
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1989, 71 (02): : 189 - 197
  • [10] DARRACH W, 1913, ANN SURG, V57, P764