Flow boiling visualization and heat transfer in metal-foam-filled mini tubes - Part I: Flow pattern map and experimental data

被引:44
作者
Abadi, Gholamreza Bamorovat [1 ]
Moon, Chanhee [1 ]
Kim, Kyung Chun [1 ]
机构
[1] Pusan Natl Univ, Sch Mech Engn, San 30, Busan 609735, South Korea
基金
新加坡国家研究基金会;
关键词
Metal foam; Flow boiling; Heat transfer; Visualization; THERMAL-ANALYSIS; PRESSURE-DROP; REFRIGERANT; EXCHANGERS; MIXTURE; R134A;
D O I
10.1016/j.ijheatmasstransfer.2016.03.043
中图分类号
O414.1 [热力学];
学科分类号
摘要
High-porosity open-cell metal foams are well known to enhance the heat transfer mechanism in rectangular or circular channels. Their high surface area to volume ratio makes them a great candidate for manufacturing high-performance small-scale heat exchangers. This two-part experimental study investigated the two-phase flow boiling inside a circular copper mini tube. In Part I, the flow pattern was visualized by high-speed imaging in glass tubes. Flow pattern maps, the heat transfer coefficient, and pressure drop are presented for mean vapor quality of 0.1-0.7, heat flux of 20-40 kW/m(2), and mass flux of 400-700 kg/m(2) s. The experiments were also performed without the metal foam in the mini tube for comparison to the original data. In this range of experimental conditions, the metal foam increased the heat transfer coefficient up to 3.2 times. Also, as expected, the metal foams adversely affected the pressure drop inside the tubes. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:857 / 867
页数:11
相关论文
共 22 条
  • [1] Abadi G.B., FLOW BOILING VISUA 2
  • [2] Thermal performance of a 10-kW phase-change plate heat exchanger with metal foam filled channels
    Abadi, Gholamreza Bamorovat
    Kim, Dae Yeon
    Yoon, Sang Youl
    Kim, Kyung Chun
    [J]. APPLIED THERMAL ENGINEERING, 2016, 99 : 790 - 801
  • [3] Flow boiling characteristics of R134a and R245fa mixtures in a vertical circular tube
    Abadi, Gholamreza Bamorovat
    Yun, Eunkoo
    Kim, Kyung Chun
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2016, 72 : 112 - 124
  • [4] Experimental study of a 1 kw organic Rankine cycle with a zeotropic mixture of R245fa/R134a
    Abadi, Gholamreza Bamorovat
    Yun, Eunkoo
    Kim, Kyung Chun
    [J]. ENERGY, 2015, 93 : 2363 - 2373
  • [5] Forced convection in high porosity metal foams
    Calmidi, VV
    Mahajan, RL
    [J]. JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2000, 122 (03): : 557 - 565
  • [6] Low-GWP refrigerants flow boiling heat transfer in a 5 PPI copper foam
    Diani, Andrea
    Mancin, Simone
    Doretti, Luca
    Rossetto, Luisa
    [J]. INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2015, 76 : 111 - 121
  • [7] GNIELINSKI V, 1976, INT CHEM ENG, V16, P359
  • [8] Effect of tube diameter on pressure drop characteristics of refrigerant-oil mixture flow boiling inside metal-foam filled tubes
    Hu, Haitao
    Zhu, Yu
    Peng, Hao
    Ding, Guoliang
    Sun, Shuo
    [J]. APPLIED THERMAL ENGINEERING, 2014, 62 (02) : 433 - 443
  • [9] Flow and heat transfer correlations for porous fin in a plate-fin heat exchanger
    Kim, SY
    Paek, JW
    Kang, BH
    [J]. JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2000, 122 (03): : 572 - 578
  • [10] Thermal analysis on metal-foam filled heat exchangers. Part I: Metal-foam filled pipes
    Lu, W.
    Zhao, C. Y.
    Tassou, S. A.
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2006, 49 (15-16) : 2751 - 2761