In vivo and in vitro evaluation of a biodegradable magnesium vascular stent designed by shape optimization strategy

被引:107
作者
Chen, Chenxin [1 ,2 ,3 ]
Chen, Jiahui [4 ]
Wu, Wei [3 ,5 ]
Shi, Yongjuan [1 ,2 ]
Jin, Liang [1 ,2 ]
Petrini, Lorenza [6 ]
Shen, Li [4 ]
Yuan, Guangyin [1 ,2 ]
Ding, Wenjiang [1 ,2 ]
Ge, Junbo [4 ]
Edelman, Elazer R. [7 ,8 ]
Migliavacca, Francesco [3 ]
机构
[1] Shanghai Jiao Tong Univ, Natl Engn Res Ctr Light Alloy Net Forming, 800 Dongchuan Rd, Shanghai 200240, Peoples R China
[2] Shanghai Jiao Tong Univ, State Key Lab Met Matrix Composite, 800 Dongchuan Rd, Shanghai 200240, Peoples R China
[3] Politecn Milan, Lab Biol Struct Mech LaBS, Dept Chem Mat & Chem Engn Giulio Natta, Piazza Leonardo da Vinci,32, I-20133 Milan, Italy
[4] Fudan Univ, Zhongshan Hosp, Dept Cardiol, Shanghai Inst Cardiovasc Dis, Shanghai 200032, Peoples R China
[5] Univ Texas San Antonio, Dept Mech Engn, One UTSA Circle, San Antonio, TX 78249 USA
[6] Politecn Milan, Dept Civil & Environm Engn, Piazza Leonardo da Vinci,32, I-20133 Milan, Italy
[7] MIT, Inst Med Engn & Sci, 77 Massachusetts Ave, Cambridge, MA 02139 USA
[8] Harvard Med Sch, Brigham & Womens Hosp, Dept Med, Cardiovasc Div, Boston, MA 02115 USA
基金
中国国家自然科学基金; 美国国家卫生研究院;
关键词
Shape optimization; Finite element method; Biodegradable magnesium alloy stent; In vitro evaluation; In vivo evaluation; ABSORB BIORESORBABLE SCAFFOLD; BARE-METAL STENTS; CARDIOVASCULAR STENTS; CORONARY-ARTERIES; CORROSION MODEL; DEGRADATION; PERFORMANCE; MULTICENTER; ALLOYS; SAFETY;
D O I
10.1016/j.biomaterials.2019.119414
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The performance of biodegradable magnesium alloy stents (BMgS) requires special attention to non-uniform residual stress distribution and stress concentration, which can accelerate localized degradation after implantation. We now report on a novel concept in stent shape optimization using a finite element method (FEM) toolkit. A Mg-Nd-Zn-Zr alloy with uniform degradation behavior served as the basis of our BMgS. Comprehensive in vitro evaluations drove stent optimization, based on observed crimping and balloon inflation performance, measurement of radial strength, and stress condition validation via microarea-XRD. Moreover, a Rapamycineluting polymer coating was sprayed on the prototypical BMgS to improve the corrosion resistance and release anti-hyperplasia drugs. In vivo evaluation of the optimized coated BMgS was conducted in the iliac artery of New Zealand white rabbit with quantitative coronary angiography (QCA), optical coherence tomography (OCT) and micro-CT observation at 1, 3, 5-month follow-ups. Neither thrombus or early restenosis was observed, and the coated BMgS supported the vessel effectively prior to degradation and allowed for arterial healing thereafter. The proposed shape optimization framework based on FEM provides an novel concept in stent design and in-depth understanding of how deformation history affects the biomechanical performance of BMgS. Computational analysis tools can indeed promote the development of biodegradable magnesium stents.
引用
收藏
页数:16
相关论文
共 65 条
  • [1] 2-year outcomes with the Absorb bioresorbable scaffold for treatment of coronary artery disease: a systematic review and meta-analysis of seven randomised trials with an individual patient data substudy
    Ali, Ziad A.
    Serruys, Patrick W.
    Kimura, Takeshi
    Gao, Runlin
    Ellis, Stephen G.
    Kereiakes, Dean J.
    Onuma, Yoshinobu
    Simonton, Charles
    Zhang, Zhen
    Stone, Gregg W.
    [J]. LANCET, 2017, 390 (10096) : 760 - 772
  • [2] [Anonymous], 2012, CARDIOVASCULAR IMP 2
  • [3] [Anonymous], 2013, F207909 ASTM
  • [4] Biomechanical Modeling to Improve Coronary Artery Bifurcation Stenting Expert Review Document on Techniques and Clinical Implementation
    Antoniadis, Antonios P.
    Mortier, Peter
    Kassab, Ghassan
    Dubini, Gabriele
    Foin, Nicolas
    Murasato, Yoshinobu
    Giannopoulos, Andreas A.
    Tu, Shengxian
    Iwasaki, Kiyotaka
    Hikichi, Yutaka
    Migliavacca, Francesco
    Chiastra, Claudio
    Wentzel, Jolanda J.
    Gijsen, Frank
    Reiber, Johan H. C.
    Barlis, Peter
    Serruys, Patrick W.
    Bhatt, Deepak L.
    Stankovic, Goran
    Edelman, Elazer R.
    Giannoglou, George D.
    Louvard, Yves
    Chatzizisis, Yiannis S.
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (10) : 1281 - 1296
  • [5] ASTM, 2012, E286012 ASTM
  • [6] ASTM, 2014, F260608 ASTM
  • [7] ASTM, 2014, F306714 ASTM
  • [8] The State of the Absorb Bioresorbable Scaffold Consensus From an Expert Panel
    Bangalore, Sripal
    Bezerra, Hiram G.
    Rizik, David G.
    Armstrong, Ehrin J.
    Samuels, Bruce
    Naidu, Srihari S.
    Grines, Cindy L.
    Foster, Malcolm T.
    Choi, James W.
    Bertolet, Barry D.
    Shah, Atman P.
    Torguson, Rebecca
    Avula, Surendra B.
    Wang, John C.
    Zidar, James P.
    Maksoud, Aziz
    Kalyanasundaram, Arun
    Yakubov, Steven J.
    Chehab, Bassem M.
    Spaedy, Anthony J.
    Potluri, Srini P.
    Caputo, Ronald P.
    Kondur, Ashok
    Merritt, Robert F.
    Kaki, Amir
    Quesada, Ramon
    Parikh, Manish A.
    Toma, Catalin
    Matar, Fadi
    DeGregorio, Joseph
    Nicholson, William
    Batchelor, Wayne
    Gollapudi, Raghava
    Korngold, Ethan
    Sumar, Riyaz
    Chrysant, George S.
    Li, Jun
    Gordon, John B.
    Dave, Rajesh M.
    Attizzani, Guilherme F.
    Stys, Tom P.
    Gigliotti, Osvaldo S.
    Murphy, Bruce E.
    Ellis, Stephen G.
    Waksman, Ron
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (23) : 2349 - 2359
  • [9] Mechanical and Corrosion Testing of Magnesium WE43 Specimens for Pitting Corrosion Model Calibration
    Boland, Enda L.
    Shirazi, Reyhaneh Neghabat
    Grogan, James A.
    McHugh, Peter E.
    [J]. ADVANCED ENGINEERING MATERIALS, 2018, 20 (10)
  • [10] Biodegradable Metals for Cardiovascular Stents: from Clinical Concerns to Recent Zn-Alloys
    Bowen, Patrick K.
    Shearier, Emily R.
    Zhao, Shan
    Guillory, Roger J., II
    Zhao, Feng
    Goldman, Jeremy
    Drelich, Jaroslaw W.
    [J]. ADVANCED HEALTHCARE MATERIALS, 2016, 5 (10) : 1121 - 1140