Effects of various operating conditions on the performance of a CO2 air conditioning system for trains

被引:27
作者
Jiang, Fuzheng [1 ]
Wang, Yufeng [1 ]
Yu, Binbin [1 ]
Wang, Dandong [1 ]
Shi, Junye [1 ,2 ]
Chen, Jiangping [1 ,2 ]
机构
[1] Shanghai Jiao Tong Univ, Inst Refrigerat & Cryogen, Shanghai, Peoples R China
[2] Shanghai High Efficient Cooling Syst Res Ctr, Shanghai, Peoples R China
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2019年 / 107卷
关键词
Air conditioning; CO2; Numerical modeling; Operating parameter; Performance; Train; EJECTOR; HEAT;
D O I
10.1016/j.ijrefrig.2019.07.009
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper aims to investigate the effects of different operating parameters on the performance of a transcritical CO2 air conditioning system for trains. Similar designs of automotive CO2 air conditioning system are used in the train system such as internal heat exchanger (IHX) to improve the system efficiency. Experimental results are presented for the performance characteristics of the CO2 train air conditioning system with two independent circuits under different test conditions such as different refrigerant charge amount, compressor working frequency, indoor air volume flow rate and outdoor chamber temperature. Two different operating modes of the two circuits are also included in this research. For mode I while only one circuit is working, the test results show that the maximum cooling capacity and coefficient of performance (COP) is 24.3 kW and 2.7, during 55Hz and 40Hz compressor working frequency conditions respectively. Also, the cooling capacity and COP reach the minimum, 16.2 kW and 1.5, when the outdoor chamber temperature is 45 degrees C. For mode II while both two circuits are working, the results show that the cooling capacity and COP are 42.0 kW and 2.4, respectively. The system performance error between the test and numerical modeling which directs the design of the system is within +5%. Furthermore, an optimum high pressure control algorithm for the transcritical CO2 cycle of the train AC system is also presented. (C) 2019 Published by Elsevier Ltd.
引用
收藏
页码:105 / 113
页数:9
相关论文
共 18 条
[1]  
Andreassen H. E. B., 2010, AIR REVERSING CO2 HE, P26
[2]   An experimental evaluation of the transcritical CO2 refrigerator performances using an internal heat exchanger [J].
Aprea, Ciro ;
Maiorino, Angelo .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (06) :1006-1011
[3]  
Brown JS, 2002, INT J REFRIG, V25, P19
[4]  
Christensen O., 2009, DEP ENERGY PROCESS E, V4-5, P21
[5]  
Harner A., 2016, P 12 IIR GUST LOR NA, P6
[6]   Thermodynamic study on a new transcritical CO2 ejector expansion refrigeration system with two-stage evaporation and vapor feedback [J].
He, Yang ;
Deng, Jianqiang ;
Zhang, Zaoxiao .
HVAC&R RESEARCH, 2014, 20 (06) :655-664
[7]   Ejector Energy-Saving Technology for Mobile Air Conditioning Systems [J].
Kawamoto, Yoichiro ;
Ogata, Gota ;
Shan, Zhiwei .
SAE International Journal of Passenger Cars - Mechanical Systems, 2017, 10 (01) :102-110
[8]  
Kolda M., 2016, P 12 IIR GUST LOR NA, P1
[9]   Studies on the performance of a CO2 air conditioning system using an ejector as an expansion device [J].
Lee, Jae Seung ;
Kim, Mo Se ;
Kim, Min Soo .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 38 :140-152
[10]   Experimental validation of model predictions on evaporator coils with an emphasis on fin efficiency [J].
Liang, S. Y. ;
Wong, T. N. .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2010, 49 (01) :187-195