Compressive behavior of hybrid double-skin tubular columns with a rib-stiffened steel inner tube

被引:55
作者
Peng, Kaidi [1 ]
Yu, Tao [1 ]
Hadi, Muhammad N. S. [1 ]
Huang, Le [1 ]
机构
[1] Univ Wollongong, Fac Engn & Informat Sci, Sch Civil Min & Environm Engn, Wollongong, NSW 2522, Australia
基金
澳大利亚研究理事会;
关键词
FRP; Tubular columns; Steel tube; Local buckling; Rib stiffener; AXIAL-COMPRESSION; CONFINED CONCRETE; STUB COLUMNS; FRP; PERFORMANCE;
D O I
10.1016/j.compstruct.2018.07.083
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Hybrid fibre-reinforced polymer (FRP)-concrete-steel double-skin tubular columns (DSTCs) consist of an outer FRP tube and an inner steel tube, with the space inbetween filled with concrete. In hybrid DSTCs, the outward buckling of the steel inner tube is constrained by the surrounding concrete and the outer FRP tube, but its inward buckling is still possible. Existing research has shown that such inward buckling can become significant in noncircular hybrid DSTCs due to the non-uniform confinement, in hybrid DSTCs with a strong FRP tube due to the large axial deformation of the columns, and/or in hybrid DSTCs with a thin steel tube. In these cases, the stiffening of the inner steel tube is necessary to prevent or delay its inward buckling and to minimize its negative consequences to the column behavior. Against this background, a variation of hybrid DSTCs (hybrid R-DSTCs), in which the inner steel tube is stiffened by a number of vertical rib stiffeners, was recently developed at the University of Wollongong, Australia. This paper presents an experimental study on the axial compressive behavior of the new form of columns. The experimental program included a total of 12 R-DSTC specimens and two DSTC specimens for comparison, with the test variables being the number, thickness and width of rib stiffeners as well as the number of plies of fibres in the FRP tube. The test results confirmed that the additional rib stiffeners on the steel tube are effective in delaying the local buckling of the steel tube and in improving the performance of the columns. The test results also clarified the effects of the tested parameters of the rib stiffeners.
引用
收藏
页码:634 / 644
页数:11
相关论文
共 27 条
[1]   Behavior of Hollow-Core FRP-Concrete-Steel Columns under Static Cyclic Flexural Loading [J].
Abdelkarim, Omar I. ;
ElGawady, Mohamed A. ;
Anumolu, Sujith ;
Gheni, Ahmed ;
Sanders, Gregory E. .
JOURNAL OF STRUCTURAL ENGINEERING, 2018, 144 (02)
[2]   Concrete-Filled-Large Deformable FRP Tubular Columns under Axial Compressive Loading [J].
Abdelkarim, Omar I. ;
ElGawady, Mohamed A. .
FIBERS, 2015, 3 (04) :432-449
[3]  
[Anonymous], 2009, 6892 BS EN ISO
[4]  
[Anonymous], 2004, STANDARD TEST METHOD
[5]  
Cavill G., 2014, P 23 AUSTR C MECH ST
[6]   Square FRP-HSC-steel composite columns: Behavior under axial compression [J].
Fanggi, Butje Alfonsius Louk ;
Ozbakkaloglu, Togay .
ENGINEERING STRUCTURES, 2015, 92 :156-171
[7]   Compressive behavior of aramid FRP-HSC-steel double-skin tubular columns [J].
Fanggi, Butje Alfonsius Louk ;
Ozbakkaloglu, Togay .
CONSTRUCTION AND BUILDING MATERIALS, 2013, 48 :554-565
[8]  
Foraboschi P, 2009, STRUCT ENG, V87, P20
[9]   Versatility of steel in correcting construction deficiencies and in seismic retrofitting of RC buildings [J].
Foraboschi, Paolo .
JOURNAL OF BUILDING ENGINEERING, 2016, 8 :107-122
[10]  
Galambos TV., 2008, STRUCTURAL STABILITY