Comparison of inversion recovery preparation schemes for lipid suppression in 1H MRSI of human brain

被引:43
作者
Ebel, A
Govindaraju, V
Maudsley, AA
机构
[1] Univ Miami, Sch Med, Dept Radiol, MR Ctr, Miami, FL 33136 USA
[2] No Calif Inst Res & Educ, San Francisco, CA USA
[3] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
[4] DVA Med Ctr San Francisco, MR Unit, San Francisco, CA USA
关键词
in vivo MR spectroscopic imaging; brain; lipid suppression; inversion recovery; lipid relaxation;
D O I
10.1002/mrm.10444
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To reduce contamination from subcutaneous lipid regions in MR spectroscopic imaging (MRSI) of whole brain, lipid signals are often suppressed using T-1 nulling methods. If a range of lipid T-1 values is present, the suppression efficiency will be improved using multiple inversion recovery (MIR) preparation. This study compared single IR (SIR) and double IR (DIR) applied with a volumetric MRSI sequence at 1.5 T based on experimental measurement of lipid T-1 and T-2 relaxation rates. At short and medium echo times (TEs), an approximately 28-47% improvement in lipid suppression was achieved with DIR compared to SIR. However, it also led to a loss of 37-43% in signal-to-noise ratio (SNR) for metabolites. Thus, SIR appears to be the better choice for suppressing lipid signals and maintaining metabolite sensitivity. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:903 / 908
页数:6
相关论文
共 21 条
[1]  
Adalsteinsson E, 1999, MAGNET RESON MED, V42, P314, DOI 10.1002/(SICI)1522-2594(199908)42:2<314::AID-MRM14>3.0.CO
[2]  
2-X
[3]   MR IMAGING - CLINICAL USE OF THE INVERSION RECOVERY SEQUENCE [J].
BYDDER, GM ;
YOUNG, IR .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (04) :659-675
[4]   MULTIPLE INVERSION RECOVERY REDUCES STATIC TISSUE SIGNAL IN ANGIOGRAMS [J].
DIXON, WT ;
SARDASHTI, M ;
CASTILLO, M ;
STOMP, GP .
MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (02) :257-268
[5]   3D PHASE ENCODING H-1 SPECTROSCOPIC IMAGING OF HUMAN BRAIN [J].
DUIJN, JH ;
MATSON, GB ;
MAUDSLEY, AA ;
WEINER, MW .
MAGNETIC RESONANCE IMAGING, 1992, 10 (02) :315-319
[6]   MULTISECTION PROTON MR SPECTROSCOPIC IMAGING OF THE BRAIN [J].
DUYN, JH ;
GILLEN, J ;
SOBERING, G ;
VANZIJL, PCM ;
MOONEN, CTW .
RADIOLOGY, 1993, 188 (01) :277-282
[7]   Assessment of 3D proton MR echo-planar spectroscopic imaging using automated spectral analysis [J].
Ebel, A ;
Soher, BJ ;
Maudsley, AA .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (06) :1072-1078
[9]   H-1-NMR CHEMICAL-SHIFT SELECTIVE (CHESS) IMAGING [J].
HAASE, A ;
FRAHM, J ;
HANICKE, W ;
MATTHAEI, D .
PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (04) :341-344
[10]   Removal of lipid artifacts in H-1 spectroscopic imaging by data extrapolation [J].
Haupt, CI ;
Schuff, N ;
Weiner, MW ;
Maudsley, AA .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (05) :678-687