Formation and removal of PCDD/Fs in a municipal waste incinerator during different operating periods

被引:45
作者
Wang, Hou Chuan
Hwang, Jyh Feng
Chi, Kai Hsien
Chang, Moo Been [1 ]
机构
[1] Natl Cent Univ, Grad Inst Environm Engn, Chungli 320, Taiwan
[2] Ind Technol Res Inst, Ctr Environm Safety & Hlth Technol, Environm Hlth & Air Pollult Div, Hsinchu 310, Taiwan
[3] Acad Sinica, Res Ctr Environm Changes, Taipei 115, Taiwan
关键词
start-up; shut-down; SCR; stack sampling; dioxin emission;
D O I
10.1016/j.chemosphere.2006.05.152
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The PCDD/F concentrations and removal efficiencies achieved with air pollution control devices (APCDs) during different operating periods (start-up, normal operation, and shut-down) at an existing municipal waste incinerator (MWI) in Taiwan are evaluated via stack sampling and analysis. The MWI investigated is equipped with electrostatic precipitators (EP), wet scrubbers (WS), and selective catalytic reduction system (SCR) as APCDs. The sampling results indicate that the PCDD/F concentrations at the EP inlet during start-up period were 15 times higher than that measured during normal operation period. The PCDD/F concentration observed at shut-down period was close to that measured at normal operation period. The CO concentration was between 400 and 1000 ppm during start-up period, which was about 50 times higher compared with the normal operation. Hence, combustion condition significantly affected the PCDD/F formation concentration during the waste incineration process. In addition, the distributions of the PCDD/F congeners were similar at different operating periods. During the normal operation and shut-down periods, the EP decreases the PCDD/F concentration (based on TEQ) by 18.4-48.6%, while the removal efficiency of PCDD/Fs achieved with SCR system reaches 99.3-99.6%. Nevertheless, the PCDD/F removal efficiency achieved with SCR was only 42% during the 19-h start-up period due to the low SCR operating temperature (195 degrees C). (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:S177 / S184
页数:8
相关论文
共 12 条
[1]  
[Anonymous], ORGANOHALOGEN COMPD
[2]   Influence of combustion conditions on the PCDD/F-, PCB-, PCBz- and PAH-concentrations in the post-combustion chamber of a waste incineration pilot plant [J].
Blumenstock, M ;
Zimmermann, R ;
Schramm, KW ;
Kettrup, A .
CHEMOSPHERE, 2000, 40 (9-11) :987-993
[3]   Evaluation of V2O5-WO3-TiO2 and alternative SCR catalysts in the abatement of VOCs [J].
Busca, G ;
Baldi, M ;
Pistarino, C ;
Amores, JMG ;
Escribano, VS ;
Finocchio, E ;
Romezzano, G ;
Bregani, F ;
Toledo, GP .
CATALYSIS TODAY, 1999, 53 (04) :525-533
[4]   Characteristics of PCDD/F congener distributions in gas/particulate phases and emissions from two municipal solid waste incinerators in Taiwan [J].
Chi, KH ;
Chang, MB ;
Chang-Chien, GP ;
Lin, C .
SCIENCE OF THE TOTAL ENVIRONMENT, 2005, 347 (1-3) :148-162
[5]   Development of new vanadium-based oxide catalysts for decomposition of chlorinated aromatic pollutants [J].
Cho, CH ;
Ihm, SK .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2002, 36 (07) :1600-1606
[6]   PCDD/F mass balance in the flue gas cleaning units of a MSW incineration plant [J].
Giugliano, M ;
Cernuschi, S ;
Grosso, M ;
Miglio, R ;
Aloigi, E .
CHEMOSPHERE, 2002, 46 (9-10) :1321-1328
[7]  
GROSSO M, 2004, ORGANOHALOGEN COMPD, V66, P1243
[8]   Formation and destruction of PCDD/F inside a grate furnace [J].
Hunsinger, H ;
Jay, K ;
Vehlow, J .
CHEMOSPHERE, 2002, 46 (9-10) :1263-1272
[9]   Removal of dioxins and related aromatic hydrocarbons from flue gas streams by adsorption and catalytic destruction [J].
Liljelind, P ;
Unsworth, J ;
Maaskant, O ;
Marklund, S .
CHEMOSPHERE, 2001, 42 (5-7) :615-623
[10]   The behavior of PCDD/Fs, PCBs, chlorobenzenes and chlorophenols in wet scrubbing system of municipal solid waste incinerator [J].
Takaoka, M ;
Liao, P ;
Takeda, N ;
Fujiwara, T ;
Oshita, K .
CHEMOSPHERE, 2003, 53 (02) :153-161