Development of an analytical methodology to quantify melamine in milk using micellar liquid chromatography and validation according to EU Regulation 2002/654/EC

被引:63
作者
Rambla-Alegre, Maria [1 ]
Peris-Vicente, Juan [1 ]
Marco-Peiro, Sergio [1 ]
Beltran-Martinavarro, Beatriz [1 ]
Esteve-Romero, Josep [1 ]
机构
[1] Univ Jaume 1, Grp Quim Bioanalit, QFA, ESTCE, Castellon de La Plana 12071, Spain
关键词
Micellar; HPLC; Melamine; Milk; Validation; TANDEM MASS-SPECTROMETRY; CYANURIC ACID; PET FOOD; METABOLITE MELAMINE; PRODUCTS; SAMPLES; CYROMAZINE; AMMELINE; IDENTIFICATION; CONFIRMATION;
D O I
10.1016/j.talanta.2010.01.034
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Melamine is a toxic triazine, illegally used as an additive in milk to apparently increase the amount of protein. A chromatographic procedure using a C18 column and a micellar mobile phase of sodium dodecyl sulphate (0.05 M) and propanol (7.5%), buffered at pH 3, and a detection set by absorbance at 210 nm, was reported for the resolution and quantification of melamine in liquid and powdered milk samples. In this work, samples were diluted with a SDS solution and were directly injected, thus avoiding long extraction and experimental procedures. Melamine was eluted in nearly 9.3 min without overlapping the protein band or other endogeneous compounds. The optimal mobile phase composition was taken using a chemometrical approach that considers the retention factor, efficiency and peak shape. Validation was performed following the European Commission's indications (European Decision 2002/657/EC), and the main analytical parameters studied were: linearity (0.02-100 ppm; r(2) = 0.999), limit of detection (5 ppb), intra- and inter-day precision (R.S.D. <7.6% and <9.7%, respectively) and robustness (R.S.D. <7.4% for retention time and <5.0% for area). Sensitivity was adequate to detect melamine under the safety limits proposed by the US FDA. Finally, recoveries for several milk samples were found in the 85-109% range. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:894 / 900
页数:7
相关论文
共 50 条
[41]   Determination of Chloramphenicol in Honey Using Salting-Out Assisted Liquid-Liquid Extraction Coupled with Liquid Chromatography-Tandem Mass Spectrometry and Validation According to 2002/657 European Commission Decision [J].
Rizzo, Serena ;
Russo, Mariateresa ;
Labra, Massimo ;
Campone, Luca ;
Rastrelli, Luca .
MOLECULES, 2020, 25 (15)
[42]   Development, validation and application of a fast analytical methodology for the simultaneous determination of DNA- and RNA-derived urinary nucleosides by liquid chromatography coupled to tandem mass spectrometry [J].
Rodriguez-Gonzalo, Encarnacion ;
Herrero-Herrero, Leticia ;
Garcia-Gomez, Diego .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1019 :132-139
[43]   Development and validation according to European Union Decision 2002/657/EC of an HPLC-DAD method for milk multi-residue analysis of penicillins and amphenicols based on dispersive extraction by QuEChERS in MSPD format [J].
Karageorgou, Eftichia G. ;
Samanidou, Victoria F. .
JOURNAL OF SEPARATION SCIENCE, 2011, 34 (15) :1893-1901
[44]   Multiresidue determination of fluoroquinolones in poultry muscle and kidney according to the regulation 2002/657/EC. A systematic comparison of two different approaches: Liquid chromatography coupled to high-resolution mass spectrometry or tandem mass spectrometry [J].
Rocha, Diego G. ;
Santos, Flavio A. ;
da Silva, Julio Cesar C. ;
Augusti, Rodinei ;
Faria, Adriana F. .
JOURNAL OF CHROMATOGRAPHY A, 2015, 1379 :83-91
[45]   Improved determination of quinolones in milk at their MRL levels using LC-UV, LC-FD, LC-MS and LC-MS/MS and validation in line with regulation 2002/657/EC [J].
Heymo, M. P. ;
Nemutlu, E. ;
Kir, S. ;
Barron, D. ;
Barbosa, J. .
ANALYTICA CHIMICA ACTA, 2008, 613 (01) :98-107
[46]   Development, validation, and comparison of four methods to simultaneously quantify L-arginine, citrulline, and ornithine in human plasma using hydrophilic interaction liquid chromatography and electrospray tandem mass spectrometry [J].
Lai, Xianyin ;
Kline, Jeffrey A. ;
Wang, Mu .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 1005 :47-55
[47]   Determination and identification, according to European Union Decision 2002/657/EC, of malachite green and its metabolite in fish by liquid chromatography-tandem mass spectrometry using an optimized extraction procedure and three-way calibration [J].
Arroyo, David ;
Cruz Ortiz, M. ;
Sarabia, Luis A. ;
Palacios, Francisco .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (29) :5472-5482
[48]   Technical note: Development and validation of a method using ultra performance liquid chromatography coupled with tandem mass spectrometry for determination of vitamin B12 concentrations in milk and dairy products [J].
Zironi, E. ;
Gazzotti, T. ;
Barbarossa, A. ;
Devicienti, C. ;
Scardilli, M. ;
Pagliuca, G. .
JOURNAL OF DAIRY SCIENCE, 2013, 96 (05) :2832-2836
[49]   Reverse Phase-High-Performance Liquid Chromatography (RP-HPLC) Method Development and Validation Using Analytical Quality-by-Design Approach for Determination of Isoliquiritigenin in Bulk and Biological Sample [J].
Nihal, P. Mohamed ;
Mohapatra, Debasish ;
Manir, Alam Mohd Adil Alam ;
Harish, Vancha ;
Singh, Sachin Kumar ;
Lad, Sakshi Upendra ;
Sutrapu, Srinivas ;
Saini, Sumant ;
Mohd, Sharfuddin .
ASSAY AND DRUG DEVELOPMENT TECHNOLOGIES, 2024, 22 (08) :409-424
[50]   Development and validation of two analytical methods for urea determination in compound feed, including pet food, and yeast using high-performance liquid chromatography coupled with fluorescence detection and tandem mass spectrometry [J].
Kraemer, Marco ;
Fry, Hildburg ;
Kappenstein, Oliver .
FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2021, 38 (06) :931-942