Fault Ride Through Capability of Fixed Speed Induction Generators Connecting to Full Converter Wind Generation System within Weak Network

被引:0
作者
Mokui, Hasmina Tari [1 ]
Masoum, Mohammad A. S. [1 ]
Mohseni, Mansour [2 ]
机构
[1] Curtin Univ, Dept Elect & Comp Engn, Perth, WA 6845, Australia
[2] APD, Perth, WA, Australia
来源
2014 IEEE 5TH INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS FOR DISTRIBUTED GENERATION SYSTEMS (PEDG) | 2014年
关键词
Reactive power control; grid codes; FSIG; full converter wind generator; fault ride through; LOW-VOLTAGE RIDE; TURBINES; FARMS; IMPROVEMENT; SUPPORT; STATCOM; DFIG;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Current grid codes request the wind turbines (WTs) to have a decent level of fault ride through (FRT) capability and also participate in recovering the network stability following contingencies. Modern WTs are mostly equipped with power converters that allow them to control the output power under various operating conditions. However, there are some Fixed Speed Induction Generators (FSIGs) still operating. FSIGs have simple and economic construction. But under fault, they are very susceptible to rotor overspeed that may lead to disconnection from the grid. For variable speed WTs, application of power converters can improve the controllability of the turbines but modifications in their PQ capability are needed to meet the network requirements. This paper is aimed to investigate the impacts of connecting full converter wind generators (FCWGs) to improve FRT capability of FSIGs within a weak network. The implemented reactive power supports set in Danish and Australian Grid Codes will be assessed based on their influences on the FRT capability of FSIGs. Impacts of FCWGs locations as reactive power providers and fault durations on the FRT capability of FSIGs will also be discussed. Results confirm that FRT capability of FSIGs can be improved in accordance with enhanced capability of FCWGs.
引用
收藏
页数:6
相关论文
共 28 条
  • [1] Anaya-Lara O., 2009, Wind Energy Generation : Modeling and Control
  • [2] [Anonymous], 2012, PM 3100 DAT SHEET
  • [3] [Anonymous], 2014, NAT EL RUL VERS 62
  • [4] Power Electronics Converters for Wind Turbine Systems
    Blaabjerg, Frede
    Liserre, Marco
    Ma, Ke
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2012, 48 (02) : 708 - 719
  • [5] Stability improvement of induction generator-based wind turbine systems
    Chen, Z.
    Hu, Y.
    Blaabjerg, F.
    [J]. IET RENEWABLE POWER GENERATION, 2007, 1 (01) : 81 - 93
  • [6] Variable Structure Control of the Active and Reactive Powers for a DFIG in Wind Turbines
    Chwa, Dongkyoung
    Lee, Kyo-Beum
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2010, 46 (06) : 2545 - 2555
  • [7] Low-voltage ride-through of a full converter wind turbine with permanent magnet generator
    Conroy, J. F.
    Watson, R.
    [J]. IET RENEWABLE POWER GENERATION, 2007, 1 (03) : 182 - 189
  • [8] Fox B., 2007, WIND POWER INTEGRATI
  • [9] Improvement of induction generator stability using braking resistors
    Freitas, W
    Morelato, A
    Xu, WS
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2004, 19 (02) : 1247 - 1249
  • [10] Real-time analysis of the transient response improvement of fixed-speed wind farms by using a reduced-scale STATCOM prototype
    Gaztanaga, Haizea
    Etxeberria-Otadui, Ion
    Ocnasu, Dan
    Bacha, Seddik
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2007, 22 (02) : 658 - 666