Accuracy and consistency of intensity-based deformable image registration in 4DCT for tumor motion estimation in liver radiotherapy planning

被引:6
|
作者
Tascon-Vidarte, Jose D. [1 ]
Stick, Line Bjerregaard [2 ]
Josipovic, Mirjana [2 ]
Risum, Signe [2 ]
Jomier, Julien [3 ]
Erleben, Kenny [1 ]
Vogelius, Ivan Richter [2 ]
Darkner, Sune [1 ]
机构
[1] Univ Copenhagen, Dept Comp Sci, Copenhagen, Denmark
[2] Dept Oncol, Copenhagen, Denmark
[3] Kitware SAS, Villeurbanne, France
来源
PLOS ONE | 2022年 / 17卷 / 07期
关键词
STEREOTACTIC BODY RADIOTHERAPY; RADIATION-THERAPY; TARGET; CT; MANAGEMENT; REDUCTION; FRAMEWORK; MODEL;
D O I
10.1371/journal.pone.0271064
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
We investigate the accuracy of intensity-based deformable image registration (DIR) for tumor localization in liver stereotactic body radiotherapy (SBRT). We included 4DCT scans to capture the breathing motion of eight patients receiving SBRT for liver metastases within a retrospective clinical study. Each patient had three fiducial markers implanted. The liver and the tumor were delineated in the mid-ventilation phase, and their positions in the other phases were estimated with deformable image registration. We tested referenced and sequential registrations strategies. The fiducial markers were the gold standard to evaluate registration accuracy. The registration errors related to measured versus estimated fiducial markers showed a mean value less than 1.6mm. The positions of some fiducial markers appeared not stable on the 4DCT throughout the respiratory phases. Markers' center of mass tends to be a more reliable measurement. Distance errors of tumor location based on registration versus markers center of mass were less than 2mm. There were no statistically significant differences between the reference and the sequential registration, i.e., consistency and errors were comparable to resolution errors. We demonstrated that intensitybased DIR is accurate up to resolution level for locating the tumor in the liver during breathing motion.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Quadratic penalty method for intensity-based deformable image registration and 4DCT lung motion recovery
    Castillo, Edward
    MEDICAL PHYSICS, 2019, 46 (05) : 2194 - 2203
  • [2] A hybrid biomechanical intensity based deformable image registration of lung 4DCT
    Samavati, Navid
    Velec, Michael
    Brock, Kristy
    MEDICAL IMAGING 2014: IMAGE PROCESSING, 2014, 9034
  • [3] A hybrid biomechanical intensity based deformable image registration of lung 4DCT
    Samavati, Navid
    Velec, Michael
    Brock, Kristy
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (08): : 3359 - 3373
  • [4] 4DCT treatment planning tools using deformable image registration
    Samant, S. S.
    Xia, J.
    Huang, M.
    Olivier, K. R.
    Chung, H.
    Liu, C.
    Chen, Y.
    Palta, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S42 - S42
  • [5] Quantification of 4DCT determined lung tumor motion based on image registration
    Choi, B
    Balter, P
    Chi, P
    Zhang, L
    Dong, L
    Mohan, R
    Cox, J
    Komaki, R
    Liu, H
    MEDICAL PHYSICS, 2005, 32 (06) : 1926 - 1926
  • [6] Evaluation of an application for intensity-based deformable image registration and dose accumulation in radiotherapy
    Thor, Maria
    Andersen, Else S.
    Petersen, Jorgen B. B.
    Sorensen, Thomas S.
    Noe, Karsten O.
    Tanderup, Kari
    Bentzen, Lise
    Elstrom, Ulrik V.
    Hoyer, Morten
    Muren, Ludvig P.
    ACTA ONCOLOGICA, 2014, 53 (10) : 1329 - 1336
  • [7] ORRN: An ODE-Based Recursive Registration Network for Deformable Respiratory Motion Estimation With Lung 4DCT Images
    Liang, Xiao
    Lin, Shan
    Liu, Fei
    Schreiber, Dimitri
    Yip, Michael
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2023, 70 (12) : 3265 - 3276
  • [8] Evaluation of Deformable Registration for Correcting Respiratory Motion in 4DCT Lung Images
    Larrue, A.
    van Elmpt, W.
    Kaster, F.
    Kadir, T.
    Gooding, M.
    MEDICAL PHYSICS, 2014, 41 (06) : 196 - 196
  • [9] Characterizing Accuracy in 4DCT Deformable Registration Using the POPI M odel
    Piper, J.
    Duchateau, M.
    Nelson, A.
    Verellen, D.
    De Ridder, M. Mark
    MEDICAL PHYSICS, 2013, 40 (06)
  • [10] Modeling Respiratory Signals by Deformable Image Registration on 4DCT Lung Images
    Bao, Pham The
    Trang, Hoang Thi Kieu
    Tuan, Tran Anh
    Thanh, Tran Thien
    Hai, Vo Hong
    BIOMED RESEARCH INTERNATIONAL, 2021, 2021