UK audit of glomerular filtration rate measurement from plasma sampling in 2013

被引:6
作者
Murray, Anthony W. [1 ]
Lawson, Richard S. [2 ]
Cade, Sarah C. [3 ]
Hall, David O. [4 ]
Kenny, Bob [5 ]
O'Shaughnessy, Emma [6 ]
Taylor, Jon [7 ]
Towey, David [8 ]
White, Duncan [9 ]
Carson, Kathryn [10 ]
机构
[1] Univ Cumbria, Dept Med & Sport Sci, Lancaster LA1 3JD, England
[2] Cent Manchester Univ Hosp NHS Fdn Trust, Dept Nucl Med, Manchester, Lancs, England
[3] Royal United Hosp Bath NHS Trust, Dept Med Phys & Bioengn, Bath, Avon, England
[4] Univ Hosp Bristol NHS Fdn Trust, Dept Med Phys & Bioengn, Bristol, Avon, England
[5] Link Med, Bramshill, England
[6] Poole Hosp NHS Fdn Trust, Dept Nucl Med, Poole, Dorset, England
[7] Sheffield Teaching Hosp NHS Fdn Trust, Dept Nucl Med, Sheffield, S Yorkshire, England
[8] Imperial Coll Healthcare NHS Trust, Radiol Sci Unit, London, England
[9] Barnsley Hosp NHS Fdn Trust, Dept Nucl Med, Barnsley, England
[10] St Lukes Hosp, Dept Nucl Med, Dublin, Ireland
关键词
audit; glomerular filtration rate; GFR; radionuclide measurement; UK; BODY-SURFACE AREA; CR-51-EDTA MEASUREMENTS; ACID CLEARANCE; FORMULA; WEIGHT; CARBOPLATIN; GUIDELINES; CHILDREN; HEIGHT; VALUES;
D O I
10.1097/MNM.0000000000000185
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
IntroductionAn audit was carried out into UK glomerular filtration rate (GFR) calculation. The results were compared with an identical 2001 audit.MethodsParticipants used their routine method to calculate GFR for 20 data sets (four plasma samples) in millilitres per minute and also the GFR normalized for body surface area. Some unsound data sets were included to analyse the applied quality control (QC) methods. Variability between centres was assessed for each data set, compared with the national median and a reference value calculated using the method recommended in the British Nuclear Medicine Society guidelines. The influence of the number of samples on variability was studied. Supplementary data were requested on workload and methodology.ResultsThe 59 returns showed widespread standardization. The applied early exponential clearance correction was the main contributor to the observed variability. These corrections were applied by 97% of centres (50% - 2001) with 80% using the recommended averaged Brochner-Mortenson correction. Approximately 75% applied the recommended Haycock body surface area formula for adults (78% for children). The effect of the number of samples used was not significant. There was wide variability in the applied QC techniques, especially in terms of the use of the volume of distribution.ConclusionThe widespread adoption of the guidelines has harmonized national GFR calculation compared with the previous audit. Further standardization could further reduce variability. This audit has highlighted the need to address the national standardization of QC methods. Radionuclide techniques are confirmed as the preferred method for GFR measurement when an unequivocal result is required. (C) 2014 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
引用
收藏
页码:1096 / 1106
页数:11
相关论文
共 32 条
  • [1] Administration of Radioactive Substances Advisory Committee, NOT GUID CLIN ADM RA
  • [2] Reference ranges for 51Cr-EDTA measurements of glomerular filtration rate in children
    Blake, GM
    Gardiner, N
    Gnanasegaran, G
    Dizdarevic, S
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 2005, 26 (11) : 983 - 987
  • [3] An evaluation of the body surface area correction for 51Cr-EDTA measurements of glomerular filtration rate
    Blake, GM
    Grewal, GS
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 2005, 26 (05) : 447 - 451
  • [4] Blaufox MD, 1996, J NUCL MED, V37, P1883
  • [5] Boyd E., 1935, GROWTH SURFACE AREA
  • [7] Brochner-Mortensen J, 1974, Scand J Clin Lab Invest, V33, P140
  • [8] CARBOPLATIN DOSAGE - PROSPECTIVE EVALUATION OF A SIMPLE FORMULA BASED ON RENAL-FUNCTION
    CALVERT, AH
    NEWELL, DR
    GUMBRELL, LA
    OREILLY, S
    BURNELL, M
    BOXALL, FE
    SIDDIK, ZH
    JUDSON, IR
    GORE, ME
    WILTSHAW, E
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 1989, 7 (11) : 1748 - 1756
  • [9] CHRISTENSEN AB, 1986, CLIN PHYSIOL, V6, P579
  • [10] UK audit of glomerular filtration rate measurement in 2001
    Cosgriff, Philip S.
    Fleming, John S.
    Jarritt, Peter H.
    Skrypniuk, John
    Bailey, Dale
    Whalley, Dave
    Houston, Alex
    Burniston, Maria
    Blake, Glen M.
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 2008, 29 (06) : 511 - 520